• 제목/요약/키워드: High temperature stress

검색결과 1,984건 처리시간 0.035초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

벼의 생산력(生産力) 분석(分析) -IV. 토양(土壤) 및 시비생산력(施肥生産力)과 시비효율(施肥效率) (Analysis of productivity in rice plant -VI. Soil and fertilization poductivity and fertilization efficiency)

  • 박훈;안상배;황영수
    • 한국토양비료학회지
    • /
    • 제7권1호
    • /
    • pp.35-42
    • /
    • 1974
  • 기존장려품종 IR 667에 대(對)하여 전국적(全國的)으로 실시한 2년간의 3요소(三要素) 요인시험(要因試驗) 결과로부터 품종간생산력(品種間生産力), 토양생산력(土壤生産力)(지력(地力))과 시비생산력(施肥生産力)(시비(施肥)에 의(依)한 증수량(增水量)을 검토(檢討)하였다. 1. IR 667은 1971년에 19%, 저온장해(低溫障害)가 있었던 72년엔 12%의 증수를 보였으며 이는 수당입수(穗當粒數)가 큰데 기인(基因)하였다. 수량(收量)의 변이계수(變異係數)는 IR667이 적었으나 장려품종이 23% (1971)와 30% (1972)의 포장에서 수량(收量)이 높았다. 2. IR 667은 질소(窒素) 특히 인산(燐酸)과 가리(加里)를 더 많이 요구(要求)하나 시비효율(施肥效率)(증수량(增收量)/시비량(施肥量))은 질소(窒素)에서만 약(約) 4kg 높고 인산(燐酸)은 장려품종보다 떨어지며 가리(加里)는 차이가 없었다. 3. IR 667에서 토양생산력(土壤生産力)은 크지만 토양생산력(土壤生産力)의 최대수량(最大收量)에의 기여도(寄與度)는 적었다. 4. 시비생산력(施肥生産力)의 기여도(寄與度)는 19~33%이며 이중 약(約) 5%만이 인산(燐酸)과 가리(加里)의 기여도(寄與度)였다. 5. 토양생산력(土壤生産力)이 커질수록 포장생산력(圃場生産力)이 커지나 시비생산력(施肥生産力)은 감소하여 지력(地力)의 기여도(寄與度)가 증가(增加)한다. 6. 시비효율(施肥效率)이 개무(皆無)인 비옥도(肥沃度)을 포화점(飽和點) 설정(設定)하고 이를 토양생산력(土壤生産力)(또는 포장생산력(圃場生産力))의 상한지표(上限指標)로 볼 수 있었다.

  • PDF

수도(水稻) 품종(品種)의 냉해관련인자(冷害關聯因子) 특성(特性)에 의(依)한 내냉성(耐冷性) 평가(評價) I. 묘(苗)에 인지질(燐脂質)의 지방산(脂肪酸) 조성(組成)과 내냉성(耐冷性) (Evaluation of Cold Tolerance in Rice Cultivars by the Characteristics Related to Chilling Injury I. Fatty Acid Composition of Phospholipid and Chilling Injury of Seedlings)

  • 석순종;하호성
    • 한국토양비료학회지
    • /
    • 제24권2호
    • /
    • pp.144-151
    • /
    • 1991
  • 수도품종(水稻品種)의 내냉성관련인자(耐冷性關聯因子)로서 생체막구성물질(生體膜構成物質)에 중요(重要)한 역할(役割)을 하는 인지질(燐脂質)의 지방산조성(脂肪酸組成)과 지방산(脂肪酸)의 불포화비율(不飽和比率)을 증가(增加)시킬 수 있는 경화처리(硬化處理)에 의한 지방산(脂肪酸)의 변화(變化)를 조사(調査)하여 포장(圃場)에서 조사(調査)된 내냉성정도(耐冷性程度)와 비교검토(比較檢討)한 결과(結果)는 다음과 같다. 1. 수도(水稻) 32품종(品種)에서 분리(分離)한 인지질(燐脂質)의 지방조성(脂肪組成)은 Pamitic, Linoleic 및 Linolenic acid가 주(主) 지방산(脂肪酸)이었고, Palmitoleic, Stearic 및 Oleic acid가 소량(少量) 함유(含有)되어 있었다. 2. 저온처리(低溫處理)($15^{\circ}C$, 3일간)한 묘(苗)에서 포화지방산(飽和脂肪酸)인 Pamitic acid의 함량(含量)은 감소하고, 불포화지방산(不飽和脂肪酸)인 Linoleic acid의 함량(含量)은 증가하였다. 3. 지방산(脂肪酸)의 불포화비율(不飽和比率)은 저온처리(低溫處理)를 하므로써 높아졌으며, 내냉성(耐冷性)이 강(强)한 품종(品種)에서 비율(比率)이 높고, 약(弱)한 품종(品種)에서 낮아 내냉성정도(耐冷性程度)와 일치(一致)하는 경향을 보였다. 4. 경화처리(硬化處理)에 의하여 인지질지방산조성(燐脂質脂肪酸組成)중 Pamitic acid는 감소하고, Linoleic acid의 함량(含量)은 증가하였다. 5. 경화처리(硬化處理)를 하므로써 지방산(脂肪酸)의 불포화비율(不飽和比率)은 대조구(對照區)에 비하여 18~24% 증가되었다.

  • PDF

하절기 가두리양식 참돔의 절식에 따른 성장과 혈액성상의 변화 (Change of Growth and Blood Characteristics on Starvation of Red Seabream Pagrus major Cultured in Marine Net Cage in Summer)

  • 김원진;원경미;신윤경;이정용
    • 한국어류학회지
    • /
    • 제29권3호
    • /
    • pp.165-175
    • /
    • 2017
  • 본 연구는 하절기에 지속적으로 발생하는 고수온, 적조와 같은 피해를 최소화하기 위한 방안으로 해상가두리 ($6m{\times}6m{\times}6m$) 절식 사육을 통해 참돔의 생존율, 성장, 성장 회복 그리고 생리반응을 조사하였다. 6주간의 절식 후 4주간의 먹이 공급을 통한 연구결과 생존율은 섭식구 94.4%, 절식구 98.1%로 나타났다. 체중 성장률은 절식구에서 $-12.4{\pm}3.2%$ 성장을 보여 체중의 유의한 감소를 보였지만, 먹이 공급 후 $36.7{\pm}6.8%$의 빠른 성장 회복을 나타냈다. 혈액분석을 통한 절식구의 영양상태 또한 섭식구에 비해 유의하게 감소하였지만 먹이 공급 후 개시 시 수준으로 빠르게 회복하였다. 또한 스트레스 지표를 분석한 결과 절식기간 섭식구의 Hb, Ht의 수치가 증가하였으며, 섭식구의 급격한 혈액성상의 변화는 하절기 해상가두리 환경에서 절식구보다 섭식구가 스트레스에 더 민감한 것으로 나타났다. 따라서 본 연구의 생존율, 성장 회복, 혈액성상을 통한 결과를 토대로, 고수온과 적조에 노출되는 하절기에 피해를 최소화하기 위한 가두리 양식어류 관리 방안으로 일정기간 절식이 활용 가능할 것으로 여겨진다.

주요 국산밀 품종과 내고온성 터키 유전자원을 이용한 내고온성 관련 SSR 마커 평가 (Evaluate of SSRs for Heat Tolerance using Korean Major Wheat Cultivars and Heat Resistant Turkey Resources)

  • 손재한;김경훈;정영근;박종철;김경호;김양길;오영진;송태화;김보경;강천식
    • 한국작물학회지
    • /
    • 제60권3호
    • /
    • pp.293-299
    • /
    • 2015
  • 밀의 등숙기간, 종자 수, 종자무게와 관련된 SSR 마커 14개를 이용하여 터키에서 분양받은 내고온성 유전자원 23개와 국산밀 품종 7개, Chinese spring 1개 등 31개를 분석한 결과, 전체 86개의 대립유전자(평균 6.14개)가 확인되었다. 평균 PIC 값은 0.64로 나타났다. 다형성 분석을 통한 마커 데이터를 이용하여 계통 분석을 한 결과 크게 세 그룹으로 형성되었다. 올밀이 가장 바깥 그룹으로 형성되었고 올그루, 고소, 조품 등이 터키자원과 다르게 단일 그룹으로 형성되었다. 금강, 조경, 백중 등 세 품종은 터키 자원들과 같은 그룹으로 나타났지만 밀접하게 연관되어 있지는 않은 것으로 나타났다. 국내 품종 중 올, 올그루, 조품, 고소 등 4개와 금강, 조경, 백중 등 3개가 서로 다른 그룹으로 형성되었다. 두 그룹의 차이는 파성 II와 III의 차이로 구별되었다.

고온내성 연료용 알코올 효모균주 Saccharomyces cerevisiae KNU5377에서 HSF1 유전자의 변이주 구축 (Construction of hsf1 Knockout-mutant of a Thermotolerant Yeast Strain Saccharomyces cerevisiae KNU5377)

  • 김일섭;윤혜선;최혜진;손호용;유춘발;김종국;진익렬
    • 생명과학회지
    • /
    • 제16권3호
    • /
    • pp.454-458
    • /
    • 2006
  • 출아효모인 Sacharomyces cerevisiae S288C균주를 이용한 효모의 게놈이 완성된 후 S. cerevisiae는 다양한 연구 모델로 이용되어져 왔다. 현재까지 효모를 이용한 기능 유전체학 측면에서의 연구는 laboratory strainin인 S288C 균주 또는 그 유래의 균주들이다. 그러나 자연에서 분리된 효모 또는 산업적으로 이용되어지고 있는 S. cerevisiae의 유전학 측면에서의 연구는 낮은 포자형성률 및 형질전환률, 그리고 S288C 균주와의 게놈상의 상이성 때문에 거의 이루어지지 않고 있다. 여기서 우리 연구진은 자연에서 분리된 Saccharomyces cerevisiae KNU5377 균주를 이용하여 random spore analysis를 통해 MATa 및 $MAT{\alpha}$ 타입의 각각의 haploid cell을 분리 후 이미 보고된 KanMX module를 가지고 round PCR기법에 의한 short flanking homology 기법을 이용하여 전사조절인자인 HSF1 유전자가 치환된 변이주를 구축할 수 있었다. 덧붙여, 모든 유전자에 이 기법을 적용할 수는 없다는 것을 확인하였다. 앞으로 이 변이주를 통해 기능 유전체학적인 측면에서 이 유전자의 스트레스와의 관련성을 연구하고자 한다.

안정적이며 지속적 밀(Triticum aestivum) 미성숙배 조직배양을 위한 스피드 브리딩 조건의 배양 효율 검정 (Evaluation of Tissue Culture Efficiency in a Speed Breeding System for Stable and Sustainable Supported Wheat (Triticum aestivum) Immature Embryogenesis)

  • 이건희;김태겸;최창현;김재윤
    • 한국작물학회지
    • /
    • 제65권4호
    • /
    • pp.365-376
    • /
    • 2020
  • 미성숙배를 이용한 조직배양은 높은 재분화율로 인하여 밀 형질전환에 적용하기 위한 가장 좋은 방법이지만 매우 한정적인 수집시기와 생육조건으로 인해 이용하기 위한 시간의 제한과 많은 노동력이 집약되어있다. 따라서 안정적이고 지속적인 미성숙배 수집을 위해 스피드 브리딩 조건을 이용하여 출수가 촉진된 밀 이삭을 이용한 미성숙배 조직배양의 효율을 검정하였고, 연구결과는 다음과 같다. 1. 스피드 브리딩 조건의 출수기는 정상조건과 비교하여 36일에서 54일까지 단축되었으며, 개화 후 11일 된 영과에서 수집된 미성숙배 조직배양의 재분화율과 소식물체 출현 비율은 정상조건과 비교하여 유의한 차이가 없다는 것을 확인하였다. 2. 두 배양 조건에서 항산화 효소 활성 분석 결과 차이가 나타나지 않았으며, 연관 표지 유전자 발현 검정을 통하여 일장과 세포분열과의 관계를 검정하여 스피드 브리딩 조건에서 수집된 이삭의 안정성을 검정하였다. 3. 본 연구 결과는 스피드 브리딩 조건을 활용한 미성숙배 조직배양에 활용될 것이며 관련 유전자 발현 및 항산화 활성 검정 결과를 통해 검증된 안정적 미성숙배는 밀 형질전환 기술 개발에 활용될 수 있을 것으로 사료된다.

수온변화에 따른 붉바리(Epinephelus akaara)의 heat shock protein (Hsp) 70 mRNA 발현 (Molecular Cloning and Expression Analysis of Red-spotted Grouper, Epinephelus akaara Hsp70)

  • 민병화;허준욱;박형준
    • 생명과학회지
    • /
    • 제28권6호
    • /
    • pp.639-647
    • /
    • 2018
  • 한국의 고급 양식대상 어종인 붉바리(Epinephelus akaara)로부터 새로운 heat shock protein (Hsp) 70을 동정하였다. 붉바리 Hsp70 (RgHsp70)의 cDNA는 RACE (rapid amplification of cDNA ends)법을 사용하였고, RgHsp70 cDNA의 전장은 2,152 bp이고, 5'-terminal untranslated region (UTR)은 105 bp, 3'-terminal UTR은 274 bp, 590개의 아미노산을 암호화하는 open reading frame (ORF)는 1,773 bp였으며, 분자무게(molecular weight)는 64.9 kDa 및 등전위값(isoelectric point, pI)은 5.2였다. 추정되는 아미노산 비교 및 계통발생학적 분석 결과, 다른 어종과 마찬가지로 Hsp70 고유의 signature를 포함하는 것을 비롯하여 높은 유사성을 나타내었으므로 RgHsp70이 Hsp70 family임을 확인할 수 있었다 RgHsp70 mRNA는 간과 두신 조직에서 높은 발현을 보였으며, 48시간 동안 수온별(21, 18, 15 및 $12^{\circ}C$) 노출 후 간 조직에서 대조구인 $21^{\circ}C$보다 $12^{\circ}C$에서 발현이 증가함을 확인하였다. 본 연구에서는, 수온이 하강함에 따라 RgHsp70 mRNA 발현에 주요한 영향을 미치는 것으로 보아, 수온변화에 따른 스트레스로 인해 발현의 변화를 나타내는 주요 스트레스성 단백질임을 확인할 수 있었다.

고랭지배추 재배지 토양보전을 위한 동반작물 도입 평가 (Evaluation of Companion Crop for Conservation of Soil in Highland Cultivativation of Chinese Cabbage)

  • 김기덕;안재훈;이정태;홍순춘;황선웅;김충국
    • 생물환경조절학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 고랭지 경사밭의 토양보전을 위해서 고랭지 배추재배지에 애기기린초, 범의귀, 지면패랭이, 긴병꽃풀 등 4종의 지피성 동반작물의 도입가능성을 경사도 5, 15 및 30%의 라이시미터에서 평가하였다. 애기기린초를 제외한 지피성 동반작물은 배추의 생육에 영향을 미치지 않았다. 배추와 동반작물에 의한 정식 이후의 피복률 변화는 동반작물보다는 배추생장에 의해 주도되었으며, 초기의 생장속도가 빨랐던 긴병꽃풀과 애기기린초 동반작물 재배구에서 초기 피복률 상승이 빠른 반면, 고온기 생장속도가 느린 범의귀와 지면패랭이는 급속한 피복도 증가를 보이지 않았다. 각각의 동반작물의 줄기와 잎의 절단 경도는 범의귀와 애기기린초가 낮은 반면, 긴병꽃풀과 지면패랭이는 매우 높아 내답압성이 우수하였다. 지피성 동반작물과 배추는 광 및 양분 경합성은 거의 없었다. 지피성 동반작물 재배구에서 배추 수관 아래 기온 및 지온은 배추 단독구보다 각각 $1^{\circ}C$내외, $0.5{\sim}1^{\circ}C$ 낮았으며, 습도는 8% 정도 높았다. 4종 지피성 동반작물을 토양보전성, 경관성, 내성, 생육 등을 고려하여 각 평가요소별 가중치를 두어 평가한 결과, 지면패랭이>긴병꽃풀>>범의귀>애기기린초의 순으로 높았고, 이중 지면패랭이가 가장 우수하였다.

압축 벤토나이트 완충재의 열팽창계수 추정 (A Prediction of Thermal Expansion Coefficient for Compacted Bentonite Buffer Materials)

  • 윤석;김건영;백민훈
    • 방사성폐기물학회지
    • /
    • 제16권3호
    • /
    • pp.339-346
    • /
    • 2018
  • 고준위폐기물을 처분하기 위한 심층처분시스템의 구성 요소로는 처분용기, 완충재, 뒷채움 및 근계 암반이 있다. 이 중 완충재는 심층 처분시스템에 있어 필수적인 요소이다. 처분용기에서 발생하는 고온의 열량은 완충재로 전파되기에 완충재의 열적 특성은 처분시스템의 안정성 평가에 상당히 중요하다고 할 수 있다. 특히, 고온의 열량은 완충재의 열적 팽창을 야기하여 근계 암반에 열응력을 야기할 수 있기에 완충재의 열팽창 특성 규명은 반드시 필요하다고 할 수 있다. 따라서 본 연구에서는 국내 경주산 압축 벤토나이트 완충재(KJ-II)에 대한 열팽창 거동 특성을 실내 실험을 통해 분석하고 선형 열팽창계수에 대한 추정 모델을 제시하고자 하였다. 압축 벤토나이트 완충재의 선형 열팽창계수는 딜라토미터 장비를 이용하여 승온속도, 건조밀도, 온도 범위에 따라 측정되었으며 선형 열팽창계수 값은 대략 $4.0{\sim}6.0{\times}10^{-6}/^{\circ}C$ 로 측정되었다. 또한 실험 데이터를 토대로 비선형 회귀분석 방법을 이용하여 건조밀도에 따른 경주 압축 벤토나이트 완충재의 선형 열팽창계수를 추정할 수 있는 모델을 제시하였다.