• 제목/요약/키워드: High temperature property

검색결과 1,248건 처리시간 0.029초

Early Age Properties of HPC Columns under Construction-Site Conditions

  • Yun, Ying-Wei;Jang, Il-Young
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권1호
    • /
    • pp.63-68
    • /
    • 2008
  • High performance concrete (HPC) is widely used in civil engineering due to its high durability and low permeability etc. Compared with ordinary concrete, HPC may develop much higher AS (autogenous shrinkage) at early age due to the relative low water cement (w/c) ratio and adding of mineral admixtures, which is one of the main reasons for early age micro-cracking of HPC structures. This paper studies the early age property of HPC columns under similar construction-site surroundings by embedded strain transducers. Results show that for HPC structure, early-age autogenous shrinkage especially within the first day after concrete pouring is pretty large. AS within the first day are 60% larger than those for 14 days in this research for all specimens. Therefore it should be taken into account for structure durability. By comparison of PHPC (plain HPC column) and RHPC (reinforced HPC column) specimens, the effects of reinforced bars on AS and temperature distribution have been analyzed. Also the influence of w/c ratio on AS is demonstrated.

Temperature Dependence of Microwave Properties of HTS Multipole Lowpass Filters Consisting of Microstrip Open-Stub Lines

  • Kim, Je-Ha;Han, Seok-Kil;Kang, Kwnag-Yong;Ahn, Dal
    • ETRI Journal
    • /
    • 제19권2호
    • /
    • pp.48-58
    • /
    • 1997
  • Using high quality high-$T_c$ superconducting (HTS) YBCO thin films, we designed and fabricated 3-pole, 5-pole, and 7-pole lowpass filters consisting of microstrip transmission lines and open-stub lines. We measured the microwave response of the filters in the temperature range of T=85 K to 27 K. AtT=30 K, the observed inband insertion loss was 0.14dB and 0.02dB for the 5-pole and 7-pole filters, respectively. The cut-off frequency was 4.7 GHz for the 5-pole filter and 7.9GHz for the 7-pole filter. To the authors' knowledge, the measured inband insertion losses are the best values reported so far for the open-stub line type HTS multipole lowpass filters. The skirt property of the 5-pole filter showed a large improvement over that of the 3-pole filter as predicted from the simulation. We found that, to obtain a stable performance, the HTS multipole lowpass filters should be operated at the temperatures between 60% and 70% of $T_c$.

  • PDF

SHS 화학로에 의한 (B.Si)C 복합체의 합성 및 기계적 특성에 관한 연구 (Study on Synthesis and Mechanical Properties of (B.Si)C Composite by Self Propagating High Temperature Synthesis Chemical Furnace)

  • 이형복;조덕호;이재원
    • 한국세라믹학회지
    • /
    • 제32권4호
    • /
    • pp.413-418
    • /
    • 1995
  • The (B.Si)C composite was prepared form the mixture of metal boron, silicon, and carbon powders in Ar atmosphere by Self-propagating High-temperature Synthesis Chemical Furnace. The characterization of synthesized power and sintered body were investigated. The microstructure of sintered body suggested that SiC boundary was made between B4C grains. The most excellent mechanical properties, the relative density of 95% oftheoretical value, 3 point flexural strength of 360MPa, and fracture toughness of 3.6MN/m3/2 could be obtained in 80wt% B4C-20 wt% SiC composite were obtained.

  • PDF

Si 첨가 고탄소강의 인장 성질에 미치는 패턴팅 조건의 영향 (The Effect of Patenting Conditions on the Tensile Property of High Carbon Steels added with Si)

  • 이준범;이상윤
    • 열처리공학회지
    • /
    • 제6권2호
    • /
    • pp.49-58
    • /
    • 1993
  • Isothermal transformation behavior during patenting and variations of microstructure and tensile strength of patented wires were investigated in Si-added high carbon steel. The TTT curves of the steels were made for two different austenitizing temperature. As the salt bath temperature was increased, the observed microstructures were bainite at $450^{\circ}C$, the mixture of bainite and pearlite at $500^{\circ}C$, and to pearlite at $600^{\circ}C$, The tensile strength of patented wire exhibited the highest value when the structure was pearlite. while the bainitic structure showed the lowest.

  • PDF

The Carbonization Behaviors of Coal Tar Pitch for Mechanical Seal

  • Chae, Jae-Hong;Kim, Kyung-Ja;Cho, Kwang-Youn;Choi, Jae-Young
    • Carbon letters
    • /
    • 제2권3_4호
    • /
    • pp.182-191
    • /
    • 2001
  • Quinoline insoluble formed by the heat treatment was hot-pressed near its softening point. The green body was stabilized in the temperature range of $300{\sim}400^{\circ}C$ and subsequently carbonized below $1300^{\circ}C$ in an argon atmosphere. The behaviors of QI formation was examined with varying the heat treatment temperature and the lapse of time of the sample carbonized at various temperatures. And the mechanical property, corrosion resistance, and friction behavior were also measured optimum content of mesophase pitch ensured a dense structure and high $LC_{(002)}$ value, which resulted in high mechanical properties, good corrosion resistance, and low-stable friction behavior.

  • PDF

SiC 보강 A16061 복합재료의 마멸 및 마찰특성에 관한 연구 (Wear and Friction Characteristics of SiC Reinforced Aluminium 6061 Alloy Composites)

  • 권재도;안정주
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2122-2132
    • /
    • 1995
  • There are some cases which require to grasp the abrasion resistance property in the fields of the high-technology to be required the high specific strength and modulus. In this study, wear test with the various test temperature and velocity were performed in the SiCw/A16061 composite and A16061 matrix using the wear test machine of the ring-on-disc type. As the results, the friction and wear properties by various test temperature and velocity were examined. The worn surface has observed by scanning electron microscope in order to examine the wear mechanism.

온도 특성을 고려한 LED 전구의 방열 및 회로 설계 (The Thermal and Circuits Design of an LED Bulb Considering Temperature Property)

  • 송상빈;여인선
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1261-1267
    • /
    • 2007
  • Although LEDs have been used in various applications with improving the brightness and luminous efficacy, the electrical and optical characteristics of high power LED varies at different temperature and starting time. In this paper, optimal heat sink and apparatus design were conducted using IR camera and ICEPAK on the LED bulb consisting with fourteen LED array. The temperatures of heat sink and LED device of the designed LED bulb without cooling pan were $74^{\circ}C\;and\;96.8^{\circ}C$, respectively, showing in good themal characteristics. For high efficiency driving circuit of LED array adopted optimal heat sink design, driving circuits of constant voltage and current circuits were suggested and fabricated. As a result the efficacy of all driving circuits showed more than 20 lm/W. Also, the constant current circuits are suitable for signal lamp, hallway lamp, and flash lamp having short operating time(about 30 min). On the other hand, a reading light and indoor lamp having long operating time can be controlled by constant voltage circuit.

전리수를 이용한 반도체 세정 공정 (Electrolyzed Water Cleaning for Semiconductor Manufacturing)

  • 류근걸;김우혁;이윤배;이종권
    • 반도체디스플레이기술학회지
    • /
    • 제2권3호
    • /
    • pp.1-6
    • /
    • 2003
  • In the rapid changes of the semiconductor manufacturing technologies for early 21st century, it may be safely said that a kernel of terms is the size increase of Si wafer and the size decrease of semiconductor devices. As the size of Si wafers increases and semiconductor device is miniaturized, the units of cleaning processes increase. A present cleaning technology is based upon RCA cleaning which consumes vast chemicals and ultra pure water (UPW) and is the high temperature process. Therefore, this technology gives rise to environmental issue. To resolve this matter, candidates of advanced cleaning processes have been studied. One of them is to apply the electrolyzed water. In this work, electrolyzed water cleaning was compared with various chemical cleaning, using Si wafer surfaces by changing cleaning temperature and cleaning time, and especially, concentrating upon the contact angle. It was observed that contact angle on surface treated with Electrolyzed water cleaning was $4.4^{\circ}$ without RCA cleaning. Amine series additive of high pKa (negative logarithm of the acidity constant) was used to observe the property changes of cathode water.

  • PDF

화재의 영향을 받은 콘크리트 구조물의 염해내구성 예측에 관한 연구 (Durability Estimation of Fire-Hit Concrete Structure to the Chloride Ion)

  • 박동천;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.219-220
    • /
    • 2010
  • The purpose of this study is to evaluate chloride ion attack durability of concrete structure having experienced the high temperature fire. Mechanical properties and anti chloride ion diffusivity of concrete specimens were measured which have experienced of 2 hours heating at $200{^{\circ}C},\;400{^{\circ}C},\;600{^{\circ}C},\;800{^{\circ}C}$. The coupling FE model of thermal transfer and chloride ion diffusion was built to predict the life expectancy of RC structure using the property values by a series of experiment.

  • PDF

조강시멘트를 이용한 한중콘크리트의 특성평가 연구 (A Study on the Cold Weather Concrete using High Early Strength Concrete)

  • 임채용;엄태선;유재상;이종열;이순기;이동호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.261-264
    • /
    • 2003
  • Cold weather can lead to many problems in mixing, placing, setting time, and curing of concrete that can have harmful effects on its properties and service life. Korean Concrete Institute (KCI) defines cold weather as a period when the average daily air temperature is less $4^{\circ}C$ and recommends to cast concrete with special care such as shielding, heating and so on. The use of high early strength cements may improve the rate of hardening characteristics of concrete in cold weather by making it possible to achieve faster setting time and evolving more hydration heat than ordinary Portland cement. Higher early strength can be achieved using Type III cement especially during the first 7 days. The strength increase property of Type III cement at low temperature was studied. As a conclusion the heat or heat insulation curing period can be reduced to 50~75%. So, it can be used for cold weather concreting to reduce construction cost and extend the construction season.

  • PDF