• Title/Summary/Keyword: High temperature performance

Search Result 3,904, Processing Time 0.029 seconds

Performance analysis of a 746 W HTS generator equipped with 70 A class contactless superconducting field exciter

  • Chae, Yoon Seok;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.1-6
    • /
    • 2020
  • This paper presents the analysis results on the electrical output performance characteristics of a 746 W high temperature superconducting generator (HTSG). The HTS field winding is charged by non-contact excitation method, i.e., contactless superconducting field exciter (CSFE) which is originated by rotary flux pump based on permanent magnet. In this paper, the preliminary current charging test was carried out using a 70 A CSFE to evaluate the performance of field exciter and analyze its non-contact excitation characteristics for the full-scale HTS field winding of the 746 W HTSG. First, the various contactless current-charging tests were conducted using assembly with HTS field winding and CSFE. Then, in order to estimate the output power performance characteristics of the 746 W HTSG, finite element analysis was conducted based on field excitation information which is experimentally measured under various operating conditions. Finally, the electrical output characteristics in no-load and load models were simulated by two-dimensional transient solver in ANSYS electromagnetics 19.0 release.

A Study of Diffusion Bonding Process for High Temperature and High Pressure Micro Channel Heat Exchanger Using Inconel 617 (인코넬 617을 이용한 고온고압용 미세채널 열교환기의 확산접합 공정에 관한 연구)

  • Song, Chan Ho;Yoon, Seok Ho;Choi, Joon Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.87-93
    • /
    • 2015
  • Recently, the heat exchangers are requiring higher performance and reliability since they are being used under the operating condition of high temperature and pressure. To satisfy these requirements, we need special materials and bonding technology. This study presents a manufacturing technology for high temperature and high pressure micro channel heat exchanger using Inconel 617. The bonding performance for diffusion bonded heat exchanger was examined and analyzed. The analysis were conducted by measuring thermal and mechanical properties such as thermal diffusivity and tensile strength, and parametric studies about bonding temperature and pressing force were also carried out. The results provided insight for bonding evaluation and the bonding condition of $1200^{\circ}C$, and 50 tons was found to be suitable for this heat exchanger. From the results, we were able to establish the base technology for the manufacturing of Inconel 617 heat exchanger through the application of the diffusion bonding.

Progresses on the Optimal Processing and Properties of Highly Porous Rare Earth Silicate Thermal Insulators

  • Wu, Zhen;Sun, Luchao;Wang, Jingyang
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.6
    • /
    • pp.527-555
    • /
    • 2018
  • High-temperature thermal insulation materials challenge extensive oxide candidates such as porus $SiO_2$, $Al_2O_3$, yttria-stabilized zirconia, and mullite, due to the needs of good mechanical, thermal, and chemical reliabilities at high temperatures simultaneously. Recently, porous rare earth (RE) silicates have been revealed to be excellent thermal insulators in harsh environments. These materials display attractive properties, including high porosity, moderately high compressive strength, low processing shrinkage (near-net-shaping), and very low thermal conductivity. The current critical challenge is to balance the excellent thermal insulation property (extremely high porosity) with their good mechanical properties, especially at high temperatures. Herein, we review the recent developments in processing techniques to achieve extremely high porosity and multiscale strengthening strategy, including solid solution strengthening and fiber reinforcement methods, for enhancing the mechanical properties of porous RE silicate ceramics. Highly porous RE silicates are highlighted as emerging high-temperature thermal insulators for extreme environments.

Microstructure Properties of Cement Matrix Exposed to High Temperature (고온에 노출 된 시멘트 매트릭스의 미세구조 특성)

  • Lee, Gun-Young;Lee, Gun-Cheol;Choi, Jung-Gu;Gao, Shan;Heo, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.24-25
    • /
    • 2015
  • To secure fundamental materials for the performance change in concrete structure damaged by fire, this study analyzed SEM and XRD of hardened cement depending on high temperature conditions. As a result, at more than 200℃, SEM and XRD were not observed because of dehydration of Ettringite; at more than 500℃, calcium hydroxide was rapidly decomposed; at more than 700℃, calcium oxide was found; at 1000℃, the highest peak point appeared.

  • PDF

Analysis on Cooling and Heating Performance of Water-to-Water Heat Pump System for Water Source Temperature (물-물 수온차 히트펌프 시스템의 원수온도에 따른 성능 특성 분석)

  • Park, Tae Jin;Cho, Yong;Park, Jin-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • The research assesses the performance of the water-to-water heat pump system installed in Cheongju water treatment plant for cooling and heating ventilation. In summer season monthly averaged COP is ranged from 3.85 to 4.56 according to the water source temperature, and the performance is increased as the raw water temperature is dropped. While, heating performance is increased for the high temperature water source, and the monthly averaged COP is changed from 2.92 to 3.82. The correlation of the water source temperature and the heat pump performance shows a linear tendency by the simple regression of average data. In heating, the COP of heat pump system linearly rises according to the water source temperature. In comparison, the COP in cooling linearly reduces as the raw water temperature is raised. The goodness of fit at the simple regression shows the coefficient of determination 82% in cooling, 46% in heating. The electric cost of water-to-water heat pump is reduced by 40% compared to that of air source heat pump.

  • PDF

High-Temperature Structural Analysis of a Medium-Scale Process Heat Exchanger Prototype (중형 공정열교환기 시제품 고온구조해석)

  • Song, Kee-Nam;Hong, Sung-Deok;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1283-1288
    • /
    • 2012
  • A process heat exchanger (PHE) in a nuclear hydrogen system is a key component for transferring the considerable heat generated in a very high temperature reactor (VHTR) to a chemical reaction that yields a large quantity of hydrogen. A performance test on a medium-scale PHE prototype made of $Hastelloy^{(R)}$-X is scheduled in a small-scale gas loop at the Korea Atomic Energy Research Institute. In this study, as a preliminary study before carrying out the performance test in the gas loop, high-temperature structural analysis modeling and macroscopic thermal and structural analysis of the medium-scale PHE prototype by imposing the established displacement boundary constraints were carried out under the gas loop test condition. The results obtained in this study will be compared with the performance test results of the medium-scale PHE prototype in the gas loop.

The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test (열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

Experimental Study on the Dependence of Variation in Performance of a High-Temperature Generator on Its Operating Conditions (운전조건 변화가 고온재생기의 성능에 미치는 영향에 관한 실험적 연구)

  • Bae, Kyungjin;Kwak, Myoungseok;Cho, Honghyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.389-397
    • /
    • 2014
  • An absorption chiller-heater using only a natural refrigerant hardly causes any environmental pollution. In an absorption chiller-heater, the performance of its high-temperature generator, which uses exhaust gases, is essential to achieving superior system performance. To investigate the performance of such a high-temperature generator, a laboratory-scale high-temperature generator working with exhaust gases was designed and tested. Changes in the performance of the high-temperature generator as a function of inlet conditions of the absorbing solution, such as air inlet temperature and mass flow, were investigated. It was observed that when the air mass flow rate ratio was increased from 80% to 120%, the heat capacity was increased by 30%, 33%, 34%, and 37%, respectively. Additionally, when the air inlet temperature was elevated from $170^{\circ}C$ to $210^{\circ}C$ for absorption solution concentrations of 56%, 55%, 545, and 53%, the heat capacity increased by 140%, 160%, 220%, and 224%, respectively.

High Temperature Stable Eletrolyte for Dye Solar Cell (염료태양전지용 고온안정성 전해질)

  • Han, Chi-Hwan;Lee, Hak-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.220-224
    • /
    • 2009
  • The effect of addition of single and binary additives on the performance of dye-sensitized $TiO_2$ solar cells based on 1,2-dimethyl-3-propylimidazolium iodide (DMPII) in ethylene carbonate (EC) and gamma-butyrolactone (GBL) has been evaluated at different cell temperatures in the $30-120^{\circ}C$ range. The electrolyte containing a single additive, 2-(dimethylamino)-pyridine (DMAP) showed best performance, which showed further enhancement for an electrolyte containing binary additives, DMAP and 5-chloro-1-ethyl-2-methylimidazole (CEMI) in equal molar ratio. The performance of the dye sensitized solar cell (DSC) based on electrolyte containing binary additives were found to be better than an acetonitrile based electrolyte. The dependence of different photovoltaic parameters (Voc, Jsc, ff, n) of the DSC upon temperature has been studied over the $30-120^{\circ}C$ range and only a small decrease in conversion efficiency has been observed. Thus the electrolyte containing binary additives (DMAP, CEMI) in EC/GBL solvent and show better performance in the investigated temperature range ($30-120^{\circ}C$).

  • PDF

Performance Analysis and Optimal Design of Heat Exchangers Used in High Temperature and High Pressure System

  • Kim, Yang-Gu;Choi, Byoung-Ik;Kim, Kui-Soon;Jeong, Ji-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • A computational study for the optimal design of heat exchangers (HX) used in a high temperature and high pressure system is presented. Two types of air to air HX are considered in this study. One is a single-pass cross-flow type with straight plain tubes and the other is a two-pass cross-counter flow type with plain U-tubes. These two types of HX have the staggered arrangement of tubes. The design models are formulated using the number of transfer units ($\varepsilon$-NTU method) and optimized using a genetic algorithm. In order to design compact light weight HX with the minimum pressure loss and the maximum heat exchange rate, the weight of HX core is chosen as the object function. Dimensions and tube pitch ratio of a HX are used as design variables. Demanded performance such as the pressure loss (${\Delta}P$) and the temperature drop (${\Delta}T$) are used as constraints. The performance of HX is discussed and their optimal designs are presented with an investigation of the effect of design variables and constraints.