• 제목/요약/키워드: High strength steel plate

검색결과 329건 처리시간 0.039초

PEMFCB금속분리판 코팅 기술 개발 : I. 표면 및 부식 특성 평가 (Development of Surface Coating Technology fey Metallic Bipolar Plate in PEMFC : I. Study on Surface and Corrosion Properties)

  • 정경우;김세융;양유창;안승균;전유택;나상묵
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.348-351
    • /
    • 2006
  • Bipolar plate, which forms about 50% of the stack cost, is an important core part with polymer electrolyte membrane in PEMFC. Bipolar plates have been commonly fabricated from graphite meterial having high electrical conductivity and corrosion resistance. Lately, many researchers have concentrated their efforts on the development of metallic bipolar plate and stainless steel has been considered as a potential material for metallic bipolar plate because of its high strength, chemical stability, low gas permeability and applicability to mass production. However, it has been reported that its inadequate corrosion behavior under PEMFC environment lead to a deterioration of membrane by dissolved metal ions and an increase in contact resistance by the growth of passive film therefore, its corrosion resistance as well as contact resistance must be improved for bipolar plate application. In this work, several types of coating were applied to 316L and their electrical conductivity and corrosion resistance were evaluated In the simulated PEMFC environment. Application of coating gave rise to low interfacial contact resistances below $19m{\Omega}cm^2$ under the compress force of $150N/cm^2$. It also made the corrosion potential to shift in the posit ive direct ion by 0.3V or above and decreased the corrosion current from ca. $9{\mu}A/cm^2$ to ca. $0.5{\mu}A/cm^2$ in the mixed solution of $0.1N\;N_2SO_4$ and 2ppm HF A coat ing layer under potentiostatic control of 0.6V and $0.75V_{SCE}$ for 500 hours or longer showed some instabilities, however, no significant change in coat Ing layer were observed from Impedance data. In addition, the corrosion current maintained less than $1{\mu}A/cm^2$ for most of time for potentiostatic tests. It indicates that high electrical conductivity and corrosion resistance can be obtained by application of coatings in the present work.

  • PDF

유한요소해석을 이용한 파열판의 특성 예측 (Property Prediction of Rupture Disc by Using Finite Element Analysis)

  • 한창용;이성범;정희석;김태구
    • 한국가스학회지
    • /
    • 제13권3호
    • /
    • pp.1-6
    • /
    • 2009
  • 최근 화학 산업이 발전함에 따라 고압설비가 널리 이용되고 있다. 이러한 고압 설비는 편리성과 함께 많은 위험을 내포하고 있다. 파열판 안전장치는 고압설비의 안전사고로부터 설비와 생명을 보호하는 장치이다. 파열판 안전장치는 홀더, 파열판, 버큠서포트로 구성되어져 있으며, 다양한 환경 조건에서 부식되거나 파괴되는 단점이 있다. 본 논문에서는 부식 저항성이 우수하여 파열판 안전장치의 소재로 많이 사용되고 있는 STS 316L stainless steel 소재를 이용해서 제작한 파열판 안전장치를 CATIA V5를 이용하여 3차원 모델링을 수행하고, 유한요소해석을 통하여 소재의 두께와 높이에 따라 파열판 안전장치의 파열에 영향을 미치는 요인을 분석하였다.

  • PDF

사다리꼴 형상의 경량체를 가진 데크형 중공슬래브의 휨 및 전단성능에 대한 실험적 연구 (Experimental Study on Bending and Shear Performance of Deck Type Void Slab with Trapezoidal Hollow Ball)

  • 김필중;김상모;박준혁
    • 한국강구조학회 논문집
    • /
    • 제29권6호
    • /
    • pp.443-453
    • /
    • 2017
  • 본 연구에서는 데크형 중공슬래브의 중공률을 확보하기 위한 방안으로 기존의 중공슬래브에 일반적으로 사용되는 구형형상의 경량체 대신 사다리꼴 형상의 경량체를 적용하고, 이에 따른 휨 및 전단 내력 성능을 실험을 통해 확인하였으며, 일방향 데크플레이트의 설치방향에 따른 구조특성을 검토하였다. 그 결과 휨내력 측면에서는 기존 구형형상의 경량체를 가진 중공슬래브와 동등한 수준의 성능을 발휘하는 것을 확인하였으며, 전단내력 측면에서는 경량체 형상 변화에 따른 차이보다는 데크플레이트의 트러스철선의 기여에 따라 큰 전단내력성능을 발휘하는 것을 확인하였다. 중공체 설치시 콘크리트 유효단면의 감소로, 전단 강도가 약 50~60% 정도로 저하된다는 기존 연구에 따른 계산한 전단내력값과 비교하였을 때, 폭방향으로 데크를 설치하여 트러스철근이 전단에 영향을 미치지 않을 것으로 가정한 실험체도 트러스철근의 트러스프레임 거동에 의한 영향으로 저감 전 값 대비 87%의 성능을 보여 기존 연구에 따른 계산전단내력보다 최대하중이 더 크게 나타났다.

EH40과 API2W강재의 극 후판재 다층 FCAW 버트 접합부 잔류응력해석 (Numerical Analysis of Welding Residual Stresses for Ultra-thick Plate of EH40 TM and API 2W Gr.50 Steel Joined by Flux Core Arc Welding)

  • 황세윤;이장현;양용식;이성제;김병종
    • Journal of Welding and Joining
    • /
    • 제28권3호
    • /
    • pp.65-72
    • /
    • 2010
  • Some structural members of large-scale marine vessels such as large-scale offshore structures and very large container ships are assembled by very thick plates of which thickness exceeds 60mm. Also, high-tensile steels have been selected to meet the required structural strength and fatigue strength. Generally, multi-pass welding method such as FCA(Flux-Core Arc) welding has been used to join the thick plates. Considering the welding residual stresses, fatigue strength of the welded joints of thick plates should be assured since the residual stress influences the fatigue strength. This paper presents a numerical procedure to investigate the residual stress of structure joined by multi-pass FCA welding so that it can be incorporated into the fatigue strength assessment considering the effect of welding residual stress. The residual stress distribution is also measured by X-Ray diffraction method. The residual stress obtained by the computational model also has been compared with that of experiment. The results of FEA are in very good agreement with the experimental measurements.

Structural performance of ribbed ferrocement plates reinforced with composite materials

  • Shaheen, Yousry B.I.;Mahmoud, Ashraf M.;Refat, Hala M.
    • Structural Engineering and Mechanics
    • /
    • 제60권4호
    • /
    • pp.567-594
    • /
    • 2016
  • The main objective of the current research is estimating the flexural behavior of ferrocement Ribbed Plates reinforced with composite material. Experimental investigation was carried out on fifteen plates; their dimensions were kept constant at 1200 mm in length, 600 mm width and 100 mm thick but with different volume fraction of steel reinforcement and number of ribs. Test specimens were tested until failure under three line loadings with simply supported conditions over a span of 1100 mm. Cracking patterns, tensile and compressive strains, deformation characteristics, ductility ratio, and energy absorption properties were observed and measured at all stages of loadings. Experimental results were compared to analytical models using ANSYS 10 program. Parametric study is presented to look at the variables that can mainly affect the mechanical behaviors of the model such as the change of plate length. The results showed that the ultimate strength, ductility ratio and energy absorption properties of the proposed ribbed plates are affected by the volume fraction and the type of reinforcement, and also proved the effectiveness of expanded metal mesh and woven steel mesh in reinforcing the ribbed ferrocement plates. In addition, the developed ribbed ferrocement plates have high strength, ductility ratio and energy absorption properties and are lighter in weight compared to the conventional RC ribbed plates, which could be useful for developed and developing countries alike. The Finite Element (FE) simulations gave good results comparing with the experimental results.

미생물 전기화학 기술이 적용된 단일 혐기성소화조에서 전극재질에 따른 바이오가스 생성 효율 평가 (Evaluation of Biogas Production Rate by using Various Electrodes Materials in a Combined Anaerobic Digester and Microbial Electrochemical Technology (MET))

  • 신원범;박준규;이범;김용근;전항배
    • 대한환경공학회지
    • /
    • 제39권2호
    • /
    • pp.82-88
    • /
    • 2017
  • 최근, 미생물전기화학기술(microbial electrochemical technology, MET)을 혐기성 소화에 적용하여 바이오가스 발생량을 증대시키는 연구가 활발하게 이루어지고 있다. 하지만, 내부저항에 따른 Scale-up 측면에서는 아직 활발한 연구가 필요하며, 내부저항을 최소화하기 위한 방안으로는 전류밀도가 높은 전극의 선정, 이온강도 및 전기전도도의 증가, 다양한 전극의 형태 및 재질 선정 등이 보고되고 있다. 최근 Stainless steel은 내구성이 강할 뿐만 아니라 비용 역시 저렴하고, 특히 음극으로 사용되는 경우 백금 금속이나 탄소기반의 섬유재질의 전극과 유사한 효율이 나타남에 따라 그 관심이 높아지고 있다. 따라서, 본 연구에서는 Graphite carbon에 전기전도도 및 전류밀도, 내구성을 향상시킬 수 있는 Ni, Cu, Fe의 코팅 여부와 최근 주목받고 있는 Stainless steel 재질의 판형과 그물망 형태의 전극을 사용하여 전기화학적 특성과 바이오가스 발생량을 비교함으로서 그 효율을 평가하였다. 그 결과, 각 전극 재질에 따른 전류밀도는 $GC-C_M$, GC, SUS-P, SUS-M이 각각 2.03, 1.36, 1.04, $1.13A/m^2$으로 나타났으며, 메탄수율은 $GC-C_M$, GC, SUS-P, SUS-M이 각각 0.27, 0.14, 0.19, 0.21 $L-CH_4/g-COD_{rem.}$로 나타났다. 즉, Stainless 재질의 금속이 코팅된 Graphite carbon과 유사한 전류밀도와 메탄수율을 나타냄을 확인할 수 있었다.

고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구(2) (An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(2))

  • 신경재;곽명근;배규웅;오영석;문정호
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.603-610
    • /
    • 2006
  • 철근콘크리트 구조물의 외부 비부착 보강방식은 다른 보강기법과 비교하여 설치가 빠르며 간단하다는 장점을 가진다. 고장력 인장봉을 사용한 보강방식은 강판 또는 탄소섬유쉬트 부착공법과는 달리 설치를 위한 콘크리트 표면가공이 필요치 않고 환경적인 조건에 영향을 받지 않는다. 본 연구를 통해 개발된 보강방식은 정착핀 또는 정착판을 통하여 보의 단부에서 고장력 인장봉과 RC보를 연결하는 보강방식이다. 여기에 편심기를 통하여 외부보강 강봉이 RC보의 곡률에 대응하도록 하였다. 본 논문에서는 보강된 RC보에 관한 총 10개의 실험체 제작하여 실험을 실시하였다. 실험의 주요 변수는 보강재료의 직경, 강봉 보강의 깊이와 개수이다. 본 논문에서는 본 연구를 통하여 개발된 보강공법으로 보강된 RC보의 구조적 거동을 기술하였으며, 보강된 RC보의 실험 결과를 무보강 실험체와 비교하였다. 실험결과 제안된 보강방법은 무보강 실험체와 비교하여 매우 우수한 강도 증진효과를 나타내었고 편심장치의 사용은 효율성을 향상시켰다. 또한, 두개의 편심기를 사용한 실험체는 1개의 편심장치를 사용한 실험체에 비해 모멘트 성능이 우수하였고, 외부보강 강봉은 보의 휨강도 뿐만 아니라 전단강도를 향상시키는 결과도 가져왔다.

다양한 장애물에 대한 60GHz 대역에서의 투과 및 반사 특성 측정 (Transmission and Reflection Characteristics Measurements at the 60GHz for the Various Obstacles)

  • 송기홍
    • 한국정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.25-32
    • /
    • 2008
  • 본 논문에서는 초고속 광대역 서비스를 제공하기에 적합한 주파수 대역인 60GHz 밀리미터파대역의 전파특성을 파악하기 위하여 직접 파를 제외한 반사파 및 투과파에 대한 신호세기를 측정하여 평균 전력 및 표준 편차를 분석하였다. 먼저, 장애물 투과에 의한 수신 신호 세기를 분석 한 결과, 철문, 동판 등은 약 40dB이상의 투과 손실치를 나타내어 투과가 거의 발생하지 않았으며, 고무, 스티로폼 및 유리등이 약 3dB의 투과 손실치로 가장 적게 나타났다. 입사각이 60도 인 경우 장애물에 의한 반사파 수신신호세기는 파티션에서의 손실치가 약 22dB로서 크게 나타났으며, 벽면 반사 손실치가 약 6dB로 가장 적게 나타났다. 이상의 결과는 반사파와 투과파가 서비스 영역 결정에 영향을 미치는 WPAN과 같은 피코셀 이동통신망의 설계에 이용될 수 있을 것으로 판단된다.

화재 발생시 열응력에 의한 복합재료 과량 시스템의 거동에 관한 연구 (Numerical Study of Lightweight FRP Bridge Deck System induced by Thermal Stress by Fire)

  • 정우영;이형길;박희광;심인섭;송영진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.928-931
    • /
    • 2006
  • Due to their light weight, high stiffness-to-weight and strength-to-weight ratios, and potentially high resistance to environmental degradation, resulting in lower life-cycle costs, polymer composites, are increasingly being considered for use in civil infrastructure applications. Recently, an FRP deck has been installed on a state highway, located in New York State. In this study, a thermal stress analysis was conducted using finite element method to study failure mechanisms of the superstructure. This analysis evaluated small and large temperature gradient effects on the FRP deck considering lightweight of FRP deck and ply orientations at the interface between steel girders and FRP deck Finite element model was verified using the load tests of the bridge deck. Finally, the analytical results shows the possible failure mechanism of FRP deck under various temperature changes and its corresponding index is suddenly varied depending on the rapid change of temperature on the deck plate.

  • PDF

반복하중을 받는 콘크리트충전 강합성 기둥의 연성에 관한 연구 (A Study on the Ductility of Concrete-Filled Composite Columns under Cyclic Loading)

  • 송준엽;권영봉;김성곤
    • 한국지진공학회논문집
    • /
    • 제5권6호
    • /
    • pp.11-19
    • /
    • 2001
  • 일정한 축하중과 반복적인 횡하중을 받는 콘크리트충전 강합성 기둥의 내진성능에 관한 실험적인 연구가 수행되었다. 강합성 기둥은 충전콘크리트가 강판의 국부좌굴로 인한 내측방향의 변형을 억제하고, 강판의 콘크리트 측압에 대한 구속효과와 같은 상호작용에 의해서 콘크리트와 강재의 단순누가강도 이상의 강도증진효과를 가지며, 강재 및 콘크리트기둥에 비해 우수한 연성 및 에너지 흡수능력을 나타내었다. 단면분할법을 이용하여 콘크리트충전 강합성 기둥의 비선형 모멘트-곡률 관계를 예측해 보았으며, 이는 실험결과와 비교적 잘 일치하는 것으로 나타났다. 또한, 구조물의 내진설계의 중요한 요소인 강합성 기둥의 연성 및 응답수정계수를 평가해 보았다. 실험결과 강합성 기둥은 효과적인 내진구조 부재로 판단되었다.

  • PDF