• 제목/요약/키워드: High speed shear

검색결과 299건 처리시간 0.024초

One-bottle 상아질 접착제의 전단결합강도와 접착성에 관한 부식시간의 효과 (THE EFFECT OF ETCHING TIME ON SHEAR BOND STRENGTH AND ADAPTIBILITY OF ONE-BOTTLE DENTIN ADHESIVE)

  • 박광수;박일윤;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.240-250
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of different etching time on the shear bond strength and adaptibility of composite to enamel and dentin when used one-bottle adhesive Prime & Bond$^{TM}$ 2.0. The proximal and occlusal surfaces of 88 extracted human molars were ground to expose enamel(n=44) and dentin (=44) using diamond wheel saw. Teeth were randomly assigned to four test groups(n=11) and received the following treatments : Control group were conditioned with 36% phosphoric acid for 20 sec. according to the manufacturer's directions. Experimental 10 sec. group, 30 sec. group and 60 sec. group were conditioned with 36% phosphoric acid for 10 sec., 30 sec. and 60 sec., respectively. Teeth were rinsed and dried for 2 sec. Prime & Bond$^{TM}$ 2.0 were applied according to the manufacturer's directions and Spectrum$^{TM}$ TPH composite resins were bonded to enamel and dentin surfaces. All specimens were stored in distilled water for 24 hours. Eighty specimens were sheared in a Universal Testing Machine with a crosshead speed of 5mm/minute. One way ANOVA and LSD test were used for statistical analysis of the data. Failure modes of all specimens after shear bond strength test were examined and listed. Also, representive postfracture modes and eight specimens were examined under scanning electron microscope. The results of this study were as follows: 1. The shear bond strength to enamel was the highest value in 30 sec. group (20.68${\pm}$8.54MPa) and the lowest value in 10 sec. group (14.92${\pm}$6.07MPa), so there was significant difference of shear bond strength between two groups (p<0.05). But there was no significant difference among other groups (p>0.05). With longer etching time to enamel from 10 sec. to 30 sec., higher the shear bond strength was obtained, but the shear bond strength was decreased at 60 sec. etching time. 2. The shear bond strength to dentin was the highest value in control group (13.08${\pm}$6.25MPa) and the lowest value in 60 sec. group (9.47${\pm}$3.35MPa), but there was no significant difference among the all groups (p>0.05). The eching time over 20 sec. decreased the shear bond strength to dentin. 3. In SEM observation, the enamel and resin interfaces were showed close adaptation with no relation to etching time of enamel. And the dentin and resin interfaces were showed close adaptation at 20 sec. and 30 sec. etching time, but showed some gaps at 10 sec. and 60 sec. etching time. Accordingly, these results indicated that a appropriate etching time in Prime & Bond$^{TM}$ 2.0 was required to be 30 sec. in enamel and 20 sec. in dentin for the high shear bond strength and good adaptation between the composite resin and tooth substance.

  • PDF

초고성능 콘크리트 바닥판과 역T형 강거더의 합성보를 위한 스터드 및 퍼즐스트립 전단연결재에 관한 연구 (Stud and Puzzle-Strip Shear Connector for Composite Beam of UHPC Deck and Inverted-T Steel Girder)

  • 이경찬;조창빈;최은석;김지상
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.151-157
    • /
    • 2014
  • 초고성능 콘크리트(UHPC)의 높은 강도 및 내구성으로 인하여 교량 바닥판에 UHPC를 적용하는 연구가 활발히 진행되고 있다. UHPC 바닥판은 강도 및 강성이 기존 콘크리트보다 월등히 높아 합성된 강재 거더 상부 플랜지의 구조적 역할을 대신할 수 있을 것이므로, 이 연구에서는 상부 플랜지를 생략한 역T형 거더를 UHPC 바닥판과 합성한 형식을 제안하고자 한다. 역T형 거더를 적용함에 있어 상부플랜지에 전단연결재를 용접하는 방식으로 전단연결재를 설치할 수 없으므로, 새로운 형식의 전단연결재의 개발이 필요하다. 이 연구에서는 3가지 형식의 전단연결재를 제안하고 이들의 정적 극한강도를 실험적으로 평가하였다. 첫 번째 형식은 웨브에 스터드를 횡방향으로 직접 용접한 전단연결재이고, 두 번째는 유럽에서 개발된 퍼즐스트립 형식의 전단연결재이며, 마지막은 횡방향 스터드와 퍼즐스트립을 조합한 전단연결재이다. 실험 결과 횡방향 스터드는 AASHTO LRFD에 제시된 기존 스터드 전단연결재의 강도 설계식 보다 평균 24% 크게 나타났으나, 바닥판에 쪼갬 균열이 현저히 발생하여 이를 방지하기 위한 새로운 대책이 필요한 것으로 나타났다. 퍼즐스트립은 기존 유럽의 연구에서 제안한 극한강도 평가식 보다 40% 큰 강도를 보여, 기존의 평가식이 지나치게 보수적인 것으로 나타났다. 마지막으로 2가지를 조합한 형식의 전단연결재의 극한강도는 각각의 전단연결재의 극한강도를 산술적으로 합한 것보다 작은 극한 강도를 보였고 바닥판에 균열 또한 현저하였으므로, 조합에 따른 상승효과를 기대할 수 없었다.

축대칭 초음속 제트에서의 마하파 방사에 관한 수치적 연구 (Numerical Analysis of the Mach Wave Radiation in an Axisymmetric Supersonic Jet)

  • 김용석;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.71-77
    • /
    • 2000
  • An axisymmetric supersonic jet is simulated at a Mach number of 1.5 and a Reynolds number of $10^5$ to identify the mechanism of sound radiation from the jet. The present simulation is performed based on the high-order accuracy and high-resolution ENO(Essentially Non-Oscillatory) schemes to capture the time-dependent flow structure representing the sound source. In this simulation, optimum expansion jet is selected as a target, where the pressure at nozzle exit is equal to that of the ambient pressure, to see pure shear layer growth without effect of change in jet cross section due to expansion or shock wave generated at nozzle exit. Shock waves are generated near vortex rings, and discernible pressure waves called Mach wave are radiated in the downstream direction with an angle from the jet axis, which is characteristic of high speed jet noise. Furthermore, vortex roll-up phenomena are observed through the visualization of vorticity contours.

  • PDF

Micro Cutting of Tungsten Carbides with SEM Direct Observation Method

  • jung, Heo-Sung
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.770-779
    • /
    • 2004
  • This paper describes the micro cutting of wear resistant tungsten carbides using PCD (Poly-Crystalline Diamond) cutting tools in performance with SEM (Scanning Electron Microscope) direct observation method. Turning experiments were also carried out on this alloy (V50) using a PCD cutting tool. One of the purposes of this study is to describe clearly the cutting mechanism of tungsten carbides and the behavior of WC particles in the deformation zone in orthogonal micro cutting. Other purposes are to achieve a systematic understanding of machining characteristics and the effects of machining parameters on cutting force, machined surface and tool wear rates by the outer turning of this alloy carried out using the PCD cutting tool during these various cutting conditions. A summary of the results are as follows: (1) From the SEM direct observation in cutting the tungsten carbide, WC particles are broken and come into contact with the tool edge directly. This causes tool wear in which portions scrape the tool in a strong manner. (2) There are two chip formation types. One is where the shear angle is comparatively small and the crack of the shear plane becomes wide. The other is a type where the shear angle is above 45 degrees and the crack of the shear plane does not widen. These differences are caused by the stress condition which gives rise to the friction at the shear plane. (3) The thrust cutting forces tend to increase more rapidly than the principal forces, as the depth of cut and the cutting speed are increased preferably in the orthogonal micro cutting. (4) The tool wear on the flank face was larger than that on the rake face in the orthogonal micro cutting. (5) Three components of cutting force in the conventional turning experiments were different in balance from ordinary cutting such as the cutting of steel or cast iron. Those expressed a large value of thrust force, principal force, and feed force. (6) From the viewpoint of high efficient cutting found within this research, a proper cutting speed was 15 m/min and a proper feed rate was 0.1 mm/rev. In this case, it was found that the tool life of a PCD tool was limited to a distance of approximately 230 m. (7) When the depth of cut was 0.1 mm, there was no influence of the feed rate on the feed force. The feed force tended to decrease, as the cutting distance was long, because the tool was worn and the tool edge retreated. (8) The main tool wear of a PCD tool in this research was due to the flank wear within the maximum value of $V_{max}$ being about 260 $\mu\textrm{m}$.

아르곤 레이저의 조사시간에 따른 광중합형 글래스 아이오노머 시멘트의 상아질에 대한 전단결합강도에 관한 연구 (A STUDY ON THE SHAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENTS TO DENTIN ACCORDING TO CURING TIME INDUCED BY ARGON LASER)

  • 조영린;황호길;조영곤;오행진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.267-277
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of light-cured glass ionomer cements to dentin surface according to curing time induced by argon laser. In this study, 160 extracted human molars with sound crown were used. The dentin surface of these teeth were exposed with high speed diamond bur under water spray and polished with 120, 320, 400, 800, 1200 grits sand paper. 160 extracted human molars were randomly assigned into four groups (control, experimental 1, 2 & 3) with 40 teeth each. Control group used a visible light curing unit, XL 1000(3M Co., U.S.A) and experimental groups used argon laser($SPECTRUM^{TM}$). And then each group subdivided into two groups (A, B) according to filling materials. Subdivided A group used Fuji II LC(GC Co., Japan), B group used Vitremer(3M Co., U.S.A). The curing units and curing time of each group were as follows : Control group : visible light, 40 seconds Experimental group 1 Experimental group 2 Experimental group 3 : argon laser, 10 seconds : argon laser, 20 seconds : argon laser, 30 seconds The glass ionomer cements were bonded to dentin surface of each specimen. The specimens were stored in 100% relative humidity at 37"c for 7days. And then, the shear bond strength were measured by universal testing machine(Shimatzu Co. Japan) at crosshead speed of 5mm/min and 100kg in full scale and analyzed statistically. The following results were obtained : 1. Experimental group 2-A showed the highest shear bond strength with $9.87{\pm}1.24$ kgf and control group B showed the lowest shear bond strength with $4.08{\pm}0.78$ kgf(P<0.01). 2. The Fuji II LC showed higher shear bond strength with $9.49{\pm}1.24$ kgf than that of the Vitremer with $4.23{\pm}1.24$ kgf. There was significant difference between Fuji II LC and Vitremer(p<0.01). 3. There was no significant differences among experimental groups according to curing time induced by argon laser. 4. There was no significant differences between control group and experimental groups according to curing units.

  • PDF

Flexural performance of composite walls under out-of-plane loads

  • Sabouri-Ghomi, Saeid;Nasri, Arman;Jahani, Younes;Bhowmick, Anjan K.
    • Steel and Composite Structures
    • /
    • 제34권4호
    • /
    • pp.525-545
    • /
    • 2020
  • This paper presents a new structural system to use as retaining walls. In civil works, there is a general trend to use traditional reinforced concrete (RC) retaining walls to resist soil pressure. Despite their good resistance, RC retaining walls have some disadvantages such as need for huge temporary formworks, high dense reinforcing, low construction speed, etc. In the present work, a composite wall with only one steel plate (steel-concrete) is proposed to address the disadvantages of the RC walls. In the proposed system, steel plate is utilized not only as tensile reinforcement but also as a permanent formwork for the concrete. In order to evaluate the efficiency of the proposed SC composite system, an experimental program that includes nine SC composite wall specimens is developed. In this experimental study, the effects of different parameters such as distance between shear connectors, length of shear connectors, concrete ultimate strength, use of compressive steel plate and compressive steel reinforcement are investigated. In addition, a 3D finite element (FE) model for SC composite walls is proposed using the finite element program ABAQUS and load-displacement curves from FE analyses were compared against results obtained from physical testing. In all cases, the proposed FE model is reasonably accurate to predict the behavior of SC composite walls under out-of-plane loads. Results from experimental work and numerical study show that the SC composite wall system has high strength and ductile behavior under flexural loads. Furthermore, the design equations based on ACI code for calculating out-ofplate flexural and shear strength of SC composite walls are presented and compared to experimental database.

도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구 (The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal)

  • 김희진;김부섭
    • 대한치과기공학회지
    • /
    • 제32권3호
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

프로펠러의 날개 수 변경에 의한 432톤급 카페리여객선 선실 진동 개선에 대한 사례 연구 (A Case Study for Cabin Vibration Improvement of 432 ton class Car-ferry Ship changing Propeller Blade Number)

  • 윤현우;버광 다오;이돈출
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.443-448
    • /
    • 2014
  • Recently, car-ferry passenger ships of navigating the coast area in the inside of our country are on an increasing trend of main engine power and the height of upper structure, which is increased to ship's speed and loading of large vehicles. The most ship with high-speed main engine is happened to excessive vibration by propeller induced excitation force on account of connecting the vibration of hull's girder and the upper structure by decreasing the shear stiffness and natural frequency for increasing the height of passenger deck. In this paper, By exchanging the propeller of alteration the number of blades, it could be keep to ship's speed and it's decreased the vibration of hull part that is located passenger deck on the upper deck, which is identified by countermeasure of protection against vibration to procure the safety ship's navigation through measuring the vibration of hull structure.

  • PDF

Potential wind power generation at Khon Kaen, Thailand

  • Supachai, Polnumtiang;Kiatfa, Tangchaichit
    • Wind and Structures
    • /
    • 제35권6호
    • /
    • pp.385-394
    • /
    • 2022
  • The energy demand of the world is increasing rapidly, mainly using fossil energy, which causes environmental damage. The wind is free and clean energy to solve the environmental problems. Thailand is one of the developing nations, and the majority of its energy is obtained from petroleum, natural gas and coal. The objective of this study is to test the characteristics of wind energy at Khon Kaen in Thailand. The wind measurement tools, the 3-cup anemometers to measure wind speed, and wind vanes to measure wind direction, were mounted on a wind tower mast to record wind data at the heights of 60, 90 and 120 meters above ground level (AGL) for 5 years between January 2012 and December 2016. The results show that the annual mean wind speeds were 3.79, 4.32 and 4.66 m/s, respectively. The highest mean wind speeds occurred in June, August and December, in order, and the lowest occurred in September. The majority of prevailing wind directions were from the North-East and South-West directions. The average annual wind shear coefficient was 0.297. Furthermore, five wind turbines with rated power from 0.85 to 4.5 MW were selected to estimate the wind energy output and it was found that the maximum AEP and CF were achieved from the low cut-in speed and high hub-height wind turbines. This important information will help to develop wind energy applications, such as the plan to produce electricity and the calculation of the wind load that affects tall and large structures.

Response characteristics and suppression of torsional vibration of rectangular prisms with various width-to-depth ratios

  • Takai, Kazunori;Sakamoto, Hiroshi
    • Wind and Structures
    • /
    • 제9권1호
    • /
    • pp.1-22
    • /
    • 2006
  • The response characteristics and suppression of flow-induced vibrations of rectangular prisms with various width-to-depth ratios were experimentally investigated. The prisms were rigid and elastically mounted at both ends to enable constrained torsional vibrations only. The present study focused on torsional vibrations, one of the three types of flow-induced vibrations generated in a rectangular prism. First, the response characteristics of torsional vibrations generated in rectangular prisms were investigated by free-vibration tests. It was found that the response characteristics of torsional vibrations generated in rectangular prisms could be classified into six patterns depending on the width-to-depth ratio. Next, the response characteristics of torsional vibrations observed in the free-vibration tests were reproduced by forced-vibration tests, and the mechanisms by which the three types of flow-induced vibrations, low-speed torsional flutter, vortex excitation and high-speed torsional flutter, are generated in the rectangular prisms were elucidated on the basis of characteristics of fluid forces and visualized flow patterns. Experiments were also carried out to establish an effective method for suppressing flow-induced vibrations generated in the rectangular prisms, and it was found that low-speed torsional flutter and high-speed torsional flutter could be suppressed by placing a small normal plate upstream of the prism, which results in suppression of the alternating rolling-up of the shear layers separating from the leading edges of the prism. It was also found that vortex excitation could be suppressed by placing a splitter plate downstream of the prism, which results in suppression of the generation of wake vortices.