• 제목/요약/키워드: High speed imaging

검색결과 241건 처리시간 0.023초

초고속 성대촬영기(High-Speed Digital Imaging)를 이용한 말더듬인과 근 긴장성 발성장애인의 /이/모음 발성 시 성대 진동 양상에 관한 비교 연구 (A Comparative Study of Vocal Fold Vibratory Behaviors Shown in the Phonation of the /i/ Vowel between Persons who Stutter and Persons with Muscle Tension Dysphonia Using High-Speed Digital Imaging)

  • 정훈;안종복;박진향;최병흔;권도하
    • 말소리와 음성과학
    • /
    • 제1권4호
    • /
    • pp.195-201
    • /
    • 2009
  • The purpose of this study was to use high-speed digital imaging (HSDI) to compare vocal vibratory behaviors of persons who stutter (PWS) and persons with muscle tension dysphonia (PMTD) for uttering the /i/ vowel in a bid to identify the characteristics of vocal fold vibratory behaviors of PWS. This study surveyed seven developmental PWSs and seven PMTDs. The findings of the study indicated the following: first, regarding the two groups' vocal fold vibratory behaviors, of seven PWSs, three were found to be close vocal tract (VC) and four were found to be combination vocal tract (VCB). Of the seven PMTDs, one was found to be VC, and the other six were found to be VCB. These results indicate that a voiceprint which is different from the open vocal tract (VO) found in normal groups in research conducted by Jung, et al. (2008b) appeared in both groups of this study. Even between the two groups, there is a difference in the voiceprint before vocalization. Second, a VKG analysis was conducted to identify the two groups' vocal cord contact quotient. As a result, the PWS group's vocal cord contact quotient changed gradually from an irregular one at the initial vocalization stage to a regular one. The PMTD group continued the tension at the initial vocalization. Putting together all of these results, there is a difference in vocal fold vibratory behaviors between PWSs and PMTDs when they speak. Thus, there was a difference in muscular tension between the two groups.

  • PDF

SiO2 나노입자 현탁액의 충돌 및 퍼짐에 관한 실험적 연구 (Experimental study on impact and spreading of SiO2 nanoparticle colloidal suspension droplets)

  • 허형규;이상준
    • 한국가시화정보학회지
    • /
    • 제11권3호
    • /
    • pp.12-16
    • /
    • 2013
  • The impact and spreading behaviors of silicon dioxide nanoparticle colloidal suspension droplets were quantitatively visualized using a high-speed imaging system. Millimeter-scale droplets were generated by a syringe pump and a needle. Droplets of different velocity were impacted on a non-porous solid surface. Images were consecutively recorded using a CMOS high-speed camera at 5000 fps (frames per second) for millimeter-scale droplets. Temporal variations of droplet diameter, velocity and maximum spreading diameters were evaluated from the sequential images captured for each experimental condition. Effects of Reynolds number, Weber number, and particle concentration were investigated experimentally.

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

  • Yin, Xuetong;Li, Nan;Jia, Sen;Zhang, Xiaoliang;Li, Ye
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.229-251
    • /
    • 2021
  • Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-to-noise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상 (High-resolution Spiral-scan Imaging at 3 Tesla MRI)

  • 김판기;임종우;강승원;조상흠;전수열;임헌진;박호종;오승준;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.108-116
    • /
    • 2006
  • 목적 : 3.0 Tesla 고 자장에서 고 해상도 나선주사영상을 수행하였다. 나선주사영상은 초고속 영상기법의 하나로서, Echo Planar Imaging(EPI)에 비하여 eddy current 가 작게 발생하고, 경사자계 파형의 기울기가 완만하여 상대적으로 낮은 slew rate 를 가진 경사자계시스템으로 구현이 가능한 장점이 있다. 또한 고 자장 영상에서 고속스핀에코(Fast Spin Echo: FSE) 등의 rf 에코 기반의 고속영상방법에서 심각하게 대두되는 SAR 문제가 근원적으로 발생하지 않는 장점이 있어 고 자장에서의 초고속영상방법으로 주목을 받고 있다. 본 연구에서는 3.0 Tesla 에서 나선주사방식으로 고 해상도 영상을 얻어 고 자장 MRI에서 나선주사영상기법의 다양한 응용 가능성을 살펴보고자 한다. 대상 및 방법 : 3 Tesla 전신 자기 공명 영상 시스템에서 다양한 해상도의 나선주사영상 방법을 개발하였다. 고차(higher-order) shimming 을 통하여 영상의 화질을 개선하였고, 해상도에 맞게 interleaves 수를 조절하였다. 스핀에코 와 gradient에코 기반 나선주사영상방법을 구현하였고, 에코 time 과 repetition time, rf 회전 각도를 조절하여 영상의 대조도(contrast)와 신호대잡음비를 조절하였다. 결과 : 3 Tesla 전신 자기 공명 영상 시스템에서 나선 주사 방법을 이용하여 다양한 해상도의 영상을 얻었다. 고 자장에서 주 자장의 불균일도(inhomogeneity) 의 절대 크기가 커지기 때문에 이를 줄이기 위한 shimming 이 더욱 중요해진다. 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구하여 spherical harmonics 분석으로 고차 shimming을 하였다. 팬텀과 in-vivo 두부 영상에서 single shot 나선주사 영상으로 $100{\times}100$ 정도의 영상과 6-12 정도의 interleaves 를 적용하여 $256{\times}256$ 의 고 해상도 영상을 얻을 수 있었다. 결론 : 신호대잡음비의 향상과 스펙트럼의 분리, 뇌기능영상에서 BOLD 효과 향상 등으로 고자장 영상에 대한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다.

  • PDF

Pathological Vibratory patterns of the Vocal Folds Observed by the High Speed Digital Imaging System

  • Niimi, Seiji
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 1998년도 제10회 학술대회 심포지움
    • /
    • pp.208-209
    • /
    • 1998
  • It is generally known that many cases of pathological rough voice are characterized not by simple random perturbations but by quasi-periodic perturbations in the speech wave. However, there are few studies on the characteristics of perturbations in vocal fold vibrations associated with this type of voice. We have been conducting studies of pathological vocal fold vibration using a high-speed digital image recording system developed by our institute, Compared to the ordinary high-speed-motion picture system, the present system is compact and simple to operate and thus, it suited for pathological data collection. (omitted)

  • PDF

Spaceborne High Speed Data Link Design for Multi-Mode SAR Image Data Transmission

  • Kwag, Young-Kil
    • Journal of electromagnetic engineering and science
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2002
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution because of the strict requirement far the real-time data transmission of the massive SAR data in a limited time of mission. In this paper, based on the data lint model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.

CMOS binary image sensor with high-sensitivity metal-oxide semiconductor field-effect transistor-type photodetector for high-speed imaging

  • Jang, Juneyoung;Heo, Wonbin;Kong, Jaesung;Kim, Young-Mo;Shin, Jang-Kyoo
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.295-299
    • /
    • 2021
  • In this study, we present a complementary metal-oxide-semiconductor (CMOS) binary image sensor. It can shoot an object rotating at a high-speed by using a gate/body-tied (GBT) p-channel metal-oxide-semiconductor field-effect transistor (PMOSFET)-type photodetector. The GBT PMOSFET-type photodetector amplifies the photocurrent generated by light. Therefore, it is more sensitive than a standard N+/P-substrate photodetector. A binary operation is installed in a GBT PMOSFET-type photodetector with high-sensitivity characteristics, and the high-speed operation is verified by the output image. The binary operations circuit comprise a comparator and memory of 1- bit. Thus, the binary CMOS image sensor does not require an additional analog-to-digital converter. The binary CMOS image sensor is manufactured using a standard CMOS process, and its high- speed operation is verified experimentally.

상용화 된 고속카메라와 후두내시경을 이용한 성대촬영 방법의 소개 (Commercially Available High-Speed Cameras Connected with a Laryngoscope for Capturing the Laryngeal Images)

  • 남도현;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제21권2호
    • /
    • pp.133-138
    • /
    • 2010
  • Background and Objectives : High-speed imaging can be useful in studies of linguistic and artistic singing styles, and laryngeal examination of patients with voice disorders, particularly in irregular vocal fold vibrations. In this study, we introduce new laryngeal imaging systems which are commercially available high speed cameras connected with a laryngoscope. Materials and Method : The laryngeal images were captured from three different types of cameras. First, the adapter was made to connect with laryngoscope and Casio EX-F1 to capture the images using $2{\times}150$ Watt Halogen light source (EndoSTROB) at speeds of 1,200 tps (frame per second)($336{\times}96$). Second, Phantom Miro ex4 was used to capture the digital laryngeal images using Xenon Nova light source 175 Watt (STORZ) at speeds of 1,920 fps ($512{\times}384$). Finally, laryngeal images were captured using MotionXtra N-4 with 250 Watt halogen lamp (Olympus CLH-250) light source at speeds of 2,000tps ($384{\times}400$) by connecting with laryngoscope. All images were transformed into the Kymograph using KIPS (Kay's image processing Software) of Kay Pentex Inc. Results: Casio EX-F1 was too small to adjust the focus and screen size was diminished once the images were captured despite of high resolution images. High quality of color images could be obtained with Phantom Miro ex4 whereas good black and white images from Motion Xtra N-4 Despite of some limitations of illumination problems, limited recording time capacity, and time consuming procedures in Phantom Miro ex4 and Motion Xtra N-4, those portable devices provided high resolution images. Conclusion : All those high speed cameras could capture the laryngeal images by connecting with laryngoscope. High resolution images were able to be captured at the fixed position under the good lightness. Accordingly, these techniques could be applicable to observe the vocal fold vibration properties in the clinical practice.

  • PDF