• Title/Summary/Keyword: High resolution exposure

Search Result 142, Processing Time 0.023 seconds

Multi-camera based Images through Feature Points Algorithm for HDR Panorama

  • Yeong, Jung-Ho
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.6-13
    • /
    • 2015
  • With the spread of various kinds of cameras such as digital cameras and DSLR and a growing interest in high-definition and high-resolution images, a method that synthesizes multiple images is being studied among various methods. High Dynamic Range (HDR) images store light exposure with even wider range of number than normal digital images. Therefore, it can store the intensity of light inherent in specific scenes expressed by light sources in real life quite accurately. This study suggests feature points synthesis algorithm to improve the performance of HDR panorama recognition method (algorithm) at recognition and coordination level through classifying the feature points for image recognition using more than one multi frames.

Study on the Application of Artificial Intelligence Model for CT Quality Control (CT 정도관리를 위한 인공지능 모델 적용에 관한 연구)

  • Ho Seong Hwang;Dong Hyun Kim;Ho Chul Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Experimental Study on Surface Impact Behavior Changes of Photocurable Hydrogel Droplets According to Exposure Conditions (광경화성 하이드로겔 액적의 노광 조건에 따른 표면 충돌 거동 변화에 대한 실험적 연구)

  • Lee, Sanghyun;Kang, Dong Kwan;Lee, Sangmin
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.308-312
    • /
    • 2022
  • 3D printing technology, which creates a physical object by various material deposition, has been widely used in recent years in the manufacturing field because of its advantages. Among the various printing technologies, droplet-based 3D printing technology (e.g., Polyjet®) enables a high-resolution printing using photocurable materials such as hydrogels. Depending on the degree of light exposure, ejected photocurable droplets may have different properties (e.g., viscosity) until they collide with the substrate and it leads to the different spreading behaviors of the droplets (i.e., impact, spreading, and recoiling) during deposition on the substrate. In this study, experimental observation and analysis of the changes in hydrogel droplet viscosity and spreading behavior according to the light exposure were carried out based on high-speed image processing.

Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD (중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석)

  • Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.141-149
    • /
    • 2009
  • In this paper, quasi-static FDTD method is implemented by FORTRAN programming, and it is used for analysis of body induced current in middle frequencies. The quasi-static FDTD program is validated by comparing the calculation result with analytic solution of the test model, to which it is difficult to apply conventional FDTD. It is confirmed that the time-step is reduced by $5.68{\times}10^6$ times. Using validated numerical technique, body induced current distribution in high resolution 3-D human model is calculated for 20[kHz] magnetic field exposure and 1[MHz] electric field exposure. Also, the effect of grounding condition of both feet on the distribution and amplitude of the induced current is analyzed. It is expected that this research can be applied to various fields including safety assessment of body induced current and development of diagnosis devices using bio-electricity.

A Study on the Analysis of Multi-beam Energy for High Resolution with Maskless Lithography System Using DMD (DMD를 이용한 마스크리스 리소그래피 시스템의 고해상도 구현을 위한 다중 빔 에너지 분석에 관한 연구)

  • Kim, Jong-Su;Shin, Bong-Cheol;Cho, Yong-Kyu;Cho, Myeong-Woo;Lee, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.829-834
    • /
    • 2011
  • Exposure process is the most important technology to fabricate highly integrated circuit. Up to now, mask type lithography process has been generally used. However, it is not efficient for small quantity and/or frequently changing products. Therefore, maskless lithography technology is raised in exposure process. In this study, relations between multi-beam energy and overlay were analyzed. Exposure experiment of generating pattern was performed. It was from presented scan line by multi- beam simulation. As a result, optimal scan line distance was proposed by simulation, and micro pattern accuracy could be improved by exposure experiment using laser direct imaging system.

A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT (Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • The CT can accurately present the anatomical structure of an organ in the human body, and the resolution of the image is excellent. On Brain CT examination, the radiation sensitivity of the orbit is high and it is subject to many exposure effects. To reduce exposure dose of lens, this study compares change of exposure dose and shielding rate about non-shielding and shielding in a way of using two shielding materials, bismuth and tungsten. In this study, we used bismuth and tungsten filament as shielding materials made by 3D printing to measure the exposure dose according to the materials thickness and each of slices. To compare each shielding rate, 1 mm to 5 mm of two materials was measured with the head phantom fixed and the Magicmax universal dosimeter placed on the eye when the shielding material is not placed, and the shielding material is placed on it. In the 1 mm thick filament, the bismuth filament showed 26.8% and the tungsten filament showed 43.1% shielding rate. Therefore, tungsten presents much greater shielding effect than bismuth.

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea (국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가)

  • Hong, Yun-Chul;Lee, Kwan-Hee;Kwon, Ho-Jang;Jang, Jae-Yeon;Leem, Jong-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.4
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.

Congener Specific Profiles and Exposure Pathways of Polybrominated Diphenyl Ethers (PBDEs) in Breast Milk of Chuncheon Area (춘천지역 모유 중 폴리브롬화디페닐메테르(PBDEs)의 이성체별 분포특성과 노출경로)

  • We, Sung-Ug;Baek, In-Cheon;Park, Sang-Ah;Kang, Seong-Hoon;Cho, Yu-Jin;Cho, Bong-Hui;Yoon, Cho-Hee;Kim, Ki-Ho;Min, Byung-Yoon
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.356-364
    • /
    • 2010
  • This study was carried out to investigate the exposure pathway of PBDEs in human breast milk collected from new mothers residing in Chuncheon, a comparatively clean area in Korea. The congeners of PBDE in 22 human breast milk samples were analyzed using a high resolution gas chromatography with a high resolution mass detector. The residue level of ${\sum}PBDEs$ was higher in primipara subjects than in multipara subjects (p<0.05). The levels in this study were similar to those of people in some Asian and European countries, but were lower than those of people in north America. In the congener profiles, BDE-47 (mean contribution=36.1%) was predominant, followed by BDE-153 (27%), BDE-99 (11.7%), BDE-100 (11.1%), BDE-28 (7.9%) and BDE-183 (3.5%). The sum of BDE-47 and BDE-153 accounted for more than 50% of ${\sum}PBDEs$ in most samples. BDE-47 was highly correlated with ${\sum}PBDEs$ (r=0.94, p<0.001). No strong trend was observed between PBDE levels and a number of key biological factors (women's age, weight, height and body mass index) examined in this study, however, weak correlations were observed in PBDE levels measured against dietary habits, particularly in fish consumption frequency. It seems that Korean people might be exposed to multiple sources including products of PBDEs, and particularly food resources.