• Title/Summary/Keyword: High resolution MS

Search Result 211, Processing Time 0.025 seconds

A Study on the ADC for High Speed Data Conversion (고속 데이터 변환을 위한 ADC에 관한 연구)

  • Kim, Sun-Youb;Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.460-465
    • /
    • 2007
  • In this paper, the pipelined A/D converter with multi S/H stage structure is proposed for high resolution and high-speed data conversion rate. In order to improve a resolution and operational speed, the proposed structure increased the sampling time that is sampled input signal. In order to verify the operation characteristics 20MS/s pipelined A/D converter is designed with two S/H stage. The simulation result shows that INL and DNL are $0.52LSB{\sim}-0.63LSB$ and $0.53LSB{\sim}-0.56LSB$, respectively. Also, the designed Analog-to-Digital converter has the SNR of 43dB and power consumption is 18.5mW.

  • PDF

Value of PAX1 Methylation Analysis by MS-HRM in the Triage of Atypical Squamous Cells of Undetermined Significance

  • Li, Shi-Rong;Wang, Zhen-Ming;Wang, Yu-Hui;Wang, Xi-Bo;Zhao, Jian-Qiang;Xue, Hai-Bin;Jiang, Fu-Guo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5843-5846
    • /
    • 2015
  • Background: Detection of cervical high grade lesions in patients with atypical squamous cells of undetermined significance (ASCUS) is still a challenge. Our study tested the efficacy of the paired boxed gene 1 (PAX1) methylation analysis by methylation-sensitive high-resolution melting (MS-HRM) in the detection of high grade lesions in ASCUS and compared performance with the hybrid capture 2 (HC2) human papillomavirus (HPV) test. Materials and Methods: A total of 463 consecutive ASCUS women from primary screening were selected. Their cervical scrapings were collected and assessed by PAX1 methylation analysis (MS-HRM) and high-risk HPV-DNA test (HC2). All patients with ASCUS were admitted to colposcopy and cervical biopsies. The Chisquare test was used to test the differences of PAX1 methylation or HPV infection between groups. Results: The specificity, sensitivity, and accuracy for detecting CIN2 + lesions were: 95.6%, 82.4%, and 94.6%, respectively, for the PAX1 MS-HRM test; and 59.7%, 64.7%, and 60.0% for the HC2 HPV test. Conclusions: The PAX1 methylation analysis by MS-HRM demonstrated a better performance than the high-risk HPV-DNA test for the detection of high grade lesions (CIN2 +) in ASCUS cases. This approach could screen out the majority of low grade cases of ASCUS, and thus reduce the referral rate to colposcopy.

A 12b 100MS/s 1V 24mW 0.13um CMOS ADC for Low-Power Mobile Applications (저전력 모바일 응용을 위한 12비트 100MS/s 1V 24mW 0.13um CMOS A/D 변환기)

  • Park, Seung-Jae;Koo, Byeong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.56-63
    • /
    • 2010
  • This work proposes a 12b 100MS/s 0.13um CMOS pipeline ADC for battery-powered mobile video applications such as DVB-Handheld (DVB-H), DVB-Terrestrial (DVB-T), Satellite DMB (SDMB), and Terrestrial DMB (TDMB) requiring high resolution, low power, and small size at high speed. The proposed ADC employs a three-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. A single shared and switched op-amp for two MDACs removes a memory effect and a switching time delay, resulting in a fast signal settling. A two-step reference selection scheme for the last-stage 6b FLASH ADC reduces power consumption and chip area by 50%. The prototype ADC in a 0.13um 1P7M CMOS technology demonstrates a measured DNL and INL within 0.40LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 60.0dB and a maximum SFDR of 72.4dB at 100MS/s, respectively. The ADC with an active die area of 0.92 $mm^2$ consumes 24mW at 1.0V and 100MS/s. The FOM, power/($f_s{\times}2^{ENOB}$), of 0.29pJ/conv. is the lowest of ever reported 12b 100MS/s ADCs.

Alternative Sample Preparation Techniques in Gas Chromatographic-Mass Spectrometric Analysis of Urinary Androgenic Steroids

  • Cho, Young-Dae;Choi, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1315-1322
    • /
    • 2006
  • The following study describes the gas chromatography-mass spectrometry (GC-MS) based screening and confirmation analysis of urinary androgenic steroids. Four commercially available solid-phase extraction (SPE) cartridges, Serdolit PAD-1, Sep-pak $C_{18}$, amino-propyl, and Oasis HLB, and three different extractive organic solvents, diethyl ether, methyl tert-butyl ether (MTBE), and n-pentane, were tested for sample preparation. Overall, Oasis HLB combined with MTBE extraction provided the highest recoveries in 39 of 46 total androgenic steroids examined and it showed a good extraction yield (>82.1%) for polar steroids, such as metabolites of fluoxymesterone, oxandrolone, and stanozolol, which gave a poor recovery in both n-pentane (9.2-64.3%) and diethyl ether (22.2-73.6%) extractions. All SPE sorbents tested showed potential, because they were efficient in extraction for most or selective steroids. When applied to positive urine samples based on the results obtained, the present method allowed selective and sensitive analysis for detection of urinary androgenic steroids. The experiments showed that the high-resolution MS method is clearly more efficient than the low-resolution MS technique for the detection of many urinary steroids. However, comprehensive sample clean-up procedures also might be needed especially in confirmation analysis to increase detectability.

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

Determination of Acquisition Parameters for High-Resolution Marine Reflection Surveys through a Computer Model Study (전산모형을 통한 고해상도 다중채널 해양반사파의 획득변수 결정)

  • 김기영;주형태;홍종국;유해수
    • The Journal of Engineering Geology
    • /
    • v.4 no.2
    • /
    • pp.187-206
    • /
    • 1994
  • Through a computer model study, optimum system configuration and field parameters were determined for high-resolution marine reflection surveys. Characteristics of far-field signatures were analysed in both time and frequency domains for the six individual R/V Onnuri. The analysis shows that the cluster fired at the depth of 2m below the sea surface generates the most ideal far-field signatures among the above seismic sources. Compared with the 96-channel streamer on the R/V Onnuri, the 12-channel streamer is suitable for shallow reflection profiling due to its high resolution both in the vertical and horizontal directions despite its lower signal-to-noise ratio. Considering factors including target depth, frequency range, airgun volume, number of recording channels, and capacity of compressors, optimum values for record length, sample period, and shot interval are believed to be is, 1ms, and 3.125m or 6.25m, respectively.

  • PDF

Residual Multi Pesticides Screening of Dead Birds by Orbitrap High Resolution Mass Spectrometry (오비트랩 고분해능 질량분석기를 이용한 폐사 조류 중 다성분 잔류 농약 스크리닝 기법)

  • Lee, Doo-Hee;Kim, Bo-Kyong;Wang, Seung-Jun;Son, Ki-Dong;Jung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.269-278
    • /
    • 2017
  • BACKGROUND: The objective of this study was to evaluate screening method of residual multi pesticides in dead birds by Orbitrap high resolution mass spectrometry (HRMS) to identify the cause of death for birds. METHODS AND RESULTS: Extraction and clean-up method of residual pesticides in liver of dead birds was used QuEChERS (Quick Easy Cheap Effective Rugged and Safe) and method validations was conducted using liquid chromatography and gas chroamtography with triple-quadrupole mass spectrometer (LC/MS/MS and GC/MS/MS) Also, we were evaluated screening method for the determination of residual pesticides in liver of dead birds by LC and GC Orbitrap Mass Spectrometry. Results of method validations, Correlation coefficients of the matrix matched calibration curves were >0.978, and the method detection limits (MDLs) and limits of quantitation (LOQ) were 2.8~72.1 ng/g (18.4 ng/g on average) and 9.0~230 ng/g (58.5 ng/g on average). The accuracy ranged from 69.1%to 130% (103% on average), and the precision values were less than 14.8%(3.8%on average). The screening of residual pesticides in liver of dead birds by LC and GC Orbitrap HRMS was detected monocrotophos, carbofuran, carbosulfan, deltametrin, benfuracarb, carbofuran, phosphamidon, prochloraz in investigated samples. CONCLUSION: This results showed that accurate mass were extraction of residual pesticides in dead birds by Orbitrap HRMS. It suggested that this screening method is applicable to the residual pesticide analysis for the cause of death as a main tool.

Study on increasing the mass resolution in aerosol TOF mass spectrometer by using post focusing method (후집속 방법을 이용한 에어로졸 TOF 질량분석기의 질량분해능 향상 연구)

  • Kim, Dukhyeon;Yang, Kiho;Cha, Hyungki;Kim, Dohoon;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.483-490
    • /
    • 2005
  • Mass resolution of the time of flight aerosol mass spectrometer for an aerosol component analysis depends on the initial direction and the initial energy of the ions. We have found that the shape of the optimum post focusing electric field is not linear. The maximum electric potential should be applied to the ions whose initial direction is 90 degree. To check on the post focusing effects, we have installed a laser ablation mass spectrometer. By using this LA-MS, we have found that the average energy distribution of the laser ablated ions is 8 eV. To establish the optimum mass resolution, a time delay and a high voltage are needed, and the results of the study show that 1500 nsec, and 3.7 kV are the optimum parameters for our system respectively. The isotope mass signals of copper show a good resolution.

Detection of The Pine Trees Damaged by Pine Wilt Disease using High Resolution Satellite and Airborne Optical Imagery

  • Lee, Seung-Ho;Cho, Hyun-Kook;Lee, Woo-Kyun
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.5
    • /
    • pp.409-420
    • /
    • 2007
  • Since 1988, pine wilt disease has spread over rapidly in Korea. It is not easy to detect the damaged pine trees by pine wilt disease from conventional remote sensing skills. Thus, many possibilities were investigated to detect the damaged pines using various kinds of remote sensing data including high spatial resolution satellite image of 2000/2003 IKONOS and 2005 QuickBird, aerial photos, and digital airborne data, too. Time series of B&W aerial photos at the scale of 1:6,000 were used to validate the results. A local maximum filtering was adapted to determine whether the damaged pines could be detected or not at the tree level from high resolution satellite images, and to locate the damaged trees. Several enhancement methods such as NDVI and image transformations were examined to find out the optimal detection method. Considering the mean crown radius of pine trees, local maximum filter with 3 pixels in radius was adapted to detect the damaged trees on IKONOS image. CIR images of 50 cm resolution were taken by PKNU-3(REDLAKE MS4000) sensor. The simulated CIR images with resolutions of 1 m, 2 m, and 4 m were generated to test the possibility of tree detection both in a stereo and a single mode. In conclusion, in order to detect the pine tree damaged by pine wilt disease at a tree level from satellite image, a spatial resolution might be less than 1 m in a single mode and/or 1 m in a stereo mode.

A 8-bit 10-MHz CMOS A/D Converter (8-bit 10-MHz CMOS A/D 변환기)

  • 박창선;손주호;이준호;김종민;김동용
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.263-266
    • /
    • 1999
  • In this work, a A/D converter is implemented to obtain 8bit resolution at a conversion rate of 10MS/s for video applications. This architecture is proposed using the Pipelined architecture for high speed conversion rate and the Successive - Approximation architecture for low power consumption, and consists of two identical stages that consist of sample/hold circuit, low power comparator, voltage reference circuit and MDAC of binary weighted capacitor array. Proposed A/D converter is designed using 0.25${\mu}{\textrm}{m}$ CMOS technology The SNR is 80㏈ at a sampling rate of 10MHz with 1.95MHz sine input signal. When an 8bit 10MS/s A/D converter is simulated, the Differential Nonlinearity / Integral Nonlinearity (DNL/ INL) error are $\pm$0.5 / $\pm$2 LSB, respectively. The power consumption is 13㎽ at 10MS/s.

  • PDF