• Title/Summary/Keyword: High purity germanium detector

Search Result 39, Processing Time 0.025 seconds

Analysis of radioactivity levels and hazard assessment of black sand samples from Rashid area, Egypt

  • Abdel-Rahman, Mohamed A.E.;El-Mongy, Sayed A.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1752-1757
    • /
    • 2017
  • The aim of this study is to evaluate the radioactivity levels and radiological impacts of representative black sand samples collected from different locations in the Rashid area, Egypt. These samples were prepared and then analyzed using the high-resolution gamma ray spectroscopy technique with a high-purity germanium detector. The activity concentration ($A_c$), minimum detectable activity, absorbed gamma dose rate, external hazard index ($H_{ex}$), annual effective dose rate equivalent, radium equivalent, as well as external and internal hazard index ($H_{ex}$ and $H_{in}$, respectively) were estimated based on the measured radionuclide concentration of the $^{238}U$($^{226}Ra$) and $^{232}Th$ decay chains and $^{40}K$. The activity concentrations of the $^{238}U$, $^{232}Th$ decay series and $^{40}K$ of these samples varied from $45.11{\pm}3.1Bq/kg$ to $252.38{\pm}34.3Bq/kg$, from $64.65{\pm}6.1Bq/kg$ to $579.84{\pm}53.1Bq/kg$, and from $403.36{\pm}20.8Bq/kg$ to $527.47{\pm}23.1Bq/kg$, respectively. The activity concentration of $^{232}Th$ in Sample 1 has the highest value compared to the other samples; this value is also higher than the worldwide mean range as reported by UNSCEAR 2000. The total absorbed gamma dose rate and the annual effective dose for these samples were found to vary from 81.19 nGy/h to 497.81 nGy/h and from $99.86{\mu}Sv/y$ to $612.31{\mu}Sv/y$, which are higher than the world average values of 59 nGy/h and $70{\mu}Sv/y$, respectively. The $H_{ex}$ values were also calculated to be 3.02, 0.47, 0.63, 0.87, 0.87, 0.51 and 0.91. It was found that the calculated value of $H_{ex}$ for Sample 1 is significantly higher than the international acceptable limit of <1. The results are tabulated, depicted, and discussed within national and international frameworks, levels, and approaches.

Current status of disposal and measurement analysis of radioactive components in linear accelerators in Korea

  • Kwon, Na Hye;Shin, Dong Oh;Kim, Jinsung;Yoo, Jaeryong;Park, Min Seok;Kim, Kum Bae;Kim, Dong Wook;Choi, Sang Hyoun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.507-513
    • /
    • 2022
  • When X-ray energy above 8 MV is used, photoneutrons are generated by the photonuclear reaction, which activates the components of linear accelerator (linac). Safely managing the radioactive material, when disposing linac or replacing components, is difficult, as the standards for the radioactive material management are not clear in Korea. We surveyed the management status of radioactive components occurred from medical linacs in Korea. And we also measured the activation of each part of the discarded Elekta linac using a survey meter and portable High Purity Germanium (HPGe) detector. We found that most medical institutions did not perform radiation measurements when disposing of radioactive components. The radioactive material was either stored within the institution or collected by the manufacturer. The surface dose rate measurements showed that the parts with high surface dose rates were target, primary collimator, and multileaf collimator (MLC). 60Co nuclide was detected in most parts, whereas for the target, 60Co and 184Re nuclides were detected. Results suggest that most institutions in Korea did not have the regulations for disposing radioactive waste from linac or the management procedures and standards were unclear. Further studies are underway to evaluate short-lived radionuclides and to lay the foundation for radioactive waste management from medical linacs.

Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator

  • Kwon, Na Hye;Jang, Young Jae;Kim, Jinsung;Kim, Kum Bae;Yoo, Jaeryong;Ahn, So Hyun;Kim, Dong Wook;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.145-152
    • /
    • 2021
  • Purpose: During the treatments of cancer patients with a linear accelerator (LINAC) using photon beams with energies ≥8 MV, the components inside the LINAC head get activated through the interaction of photonuclear reaction (γ, n) and neutron capture (n, γ). We used spectroscopy and measured the dose rate for the LINAC in operation after the treatment ended. Methods: We performed spectroscopy and dose rate measurements for three units of LINACs with a portable high-purity Germanium (HPGe) detector and a survey meter. The spectra were obtained after the beams were turned off. Spectroscopy was conducted for 3,600 seconds, and the dose rate was measured three times. We identified the radionuclides for each LINAC. Results: According to gamma spectroscopy results, most of the nuclides were short-lived radionuclides with half-lives of 100 days, except for 60Co, 65Zn, and 181W nuclides. The dose rate for three LINACs obtained immediately in front of the crosshair was in the range of 0.113 to 0.129 µSv/h. The maximum and minimum dose rates measured on weekends were 0.097 µSv/h and 0.092 µSv/h, respectively. Compared with the differences in weekday data, there was no significant difference between the data measured on Saturday and Sunday. Conclusions: Most of the detected radionuclides had half-lives <100 days, and the dose rate decreased rapidly. For equipment that primarily used energies ≤10 MV, when the equipment was transferred after at least 10 minutes after shutting it down, it is expected that there will be little effect on the workers' exposure.

Assessment of Radiological Hazards in Some Foods Products Consumed by the Malian Population Using Gamma Spectrometry

  • Adama Coulibaly;David O. Kpeglo;Emmanuel O. Darko
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.84-89
    • /
    • 2023
  • Background: Food consumption is one of the most important routes for radionuclide intake for the public; therefore, there is the need to have a comprehensive understanding of the amount of radioactivity in food products. Consumption of radionuclide-contaminated food could increase potential health risks associated with exposure to radiation such as cancers. The present study aims to determine radioactivity levels in some food products (milk, rice, sugar, and wheat flour) consumed in Mali and to evaluate the radiological effect on the public health from these radionuclides. Materials and Methods: The health impact due to ingestion of radionuclides from these foods was evaluated by the determination of activity concentration of radionuclides 238U, 232Th, 40K, and 137Cs using gamma spectrometry system with high-purity germanium detector and radiological hazards index in 16 samples collected in some markets, mall, and shops of Bamako-Mali. Results and Discussion: The average activity concentrations were 9.8±0.6 Bq/kg for 238U, 8.7±0.5 Bq/kg for 232Th, 162.9±7.9 Bq/kg for 40K, and 0.0035±0.0005 Bq/kg for 137Cs. The mean values of radiological hazard parameters such as annual committed effective dose, internal hazard index, and risk assessment from this work were within the dose criteria limits given by international organizations (International Commission on Radiological Protection and United Nations Scientific Committee on the Effects of Atomic Radiation) and national standards. Conclusion: The results show low public exposure to radioactivity and associated radiological impact on public health. Nevertheless, this study stipulates vital data for future research and regulatory authorities in Mali.

Radiometric examination of fertilizers and assessment of their health hazards, commonly used in Pakistan

  • Hannan Younis;Sumbilah Shafique;Zahida Ehsan;Aleena Ishfaq;Khurram Mehboob;Muhammad Ajaz;Abdullah Hidayat;Wazir Muhammad
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2447-2453
    • /
    • 2023
  • The radioactivity concentrations of Naturally Occurring Radioactive Materials (NORM) i.e., 226Ra, 232Th, and 4K in various chemical fertilizers being used in the agricultural soil of Pakistan were determined utilizing gamma spectrometry by employing a High Purity Germanium (HPGe) detector. The radioactivity concentrations of 226Ra, 232Th, and 4K extended from 2.58 ± 0.8-265.7 ± 8.8 Bq kg-1, 1.53 ± 0.14-76.6 ± 1.07 Bq kg-1 and 36.5 ± 1.34-15606.7 ± 30.2 Bq kg-1 respectively. The radiological hazard parameters such as internal and external indices and annual effective dose rates were calculated, while excessive lifetime cancer risk factors for the indoor and outdoor areas were found in the range from 0.3×10-3 to 10.723×10-3 and 0.03×10-3 to 2.7948×10-3 of most fertilizers, however, some values were slightly higher than the UNSCEAR (The United Nations Scientific Committee on the Effects of Atomic Radiation) recommended values for potash-containing fertilizers such as MOP (Muriate of Potash).

Radionuclide concentrations in agricultural soil and lifetime cancer risk due to gamma radioactivity in district Swabi, KPK, Pakistan

  • Umair Azeem;Hannan Younis;Niamat ullah;Khurram Mehboob;Muhammad Ajaz;Mushtaq Ali;Abdullah Hidayat;Wazir Muhammad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.207-215
    • /
    • 2024
  • This study focuses on measuring the levels of naturally occurring radioactivity in the soil of Swabi, Khyber Pakhtunkhwa, Pakistan, as well as the associated health hazard. Thirty (30) soil samples were collected from various locations and analyzed for 226Ra, 232Th, and 40K radioactivity levels using a High Purity Germanium detector (HPGe) gamma-ray spectrometer with a photo-peak efficiency of approximately 52.3%. The average values obtained for these radionuclides are 35.6 ± 5.7 Bqkg-1, 47 ± 12.5 Bqkg-1, and 877 ± 153 Bqkg-1, respectively. The level of 232Th is slightly higher and 40K is 2.2 times higher than the internationally recommended limit of 30 Bqkg-1 and 400 Bqkg-1, respectively. Various parameters were calculated based on the results obtained, including Radium Equivalent (Raeq), External Hazard (Hex), Absorbed Dose Rate (D), Annual Gonadal Equivalent Dose (AGDE), Annual Effective Dose Rate, and Excess Lifetime Cancer Risk (ELCR), which are 170.3 ± 24 Bqkg-1, 0.46 ± 0.06 Bqkg-1, 81.4 ± 2.04 nGy h-1, 582 ± 78.08 µSvy-1, 99.8 ± 13.5 µSv Gy-1, and 0.349 ± 0.04, respectively. These values are below the limits recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2002. This study highlights the potential radiation threats associated with natural radioactivity levels in the soil of Swabi and provides valuable information for public health and safety.

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

Research and Verification of Distance and Dead Thickness Changes of Coaxial HPGe Detectors using PENELEOPE Simulation (PENELEOPE 시뮬레이션을 이용한 동축 HPGe 검출기의 거리 및 외부 접촉 층 두께 변화 연구 및 검증)

  • Eun-Sung Jang;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.175-184
    • /
    • 2023
  • Based on the actual shape of the detector and the data provided by the manufacturer, the shape of the detector was implemented through Penelope simulation and applied to the appropriate four-layer thickness based on the efficiency obtained from the measurements. Efficiency calculations to determine the effect of the simulated number of Full Energy Peak Efficiency(FEPE) channels in the detector and the outside contact layer in the crystal on the Full Energy Peak Efficiency were performed for various four-layer thicknesses of 0.3, 0.5, 0.7, 1.0, 1.2, and 1.4 mm using the Penelope Code. When the thickness of the external contact layer was increased by 5 times, the Full Energy Peak Efficiency decreased by about 36% for 59.50 keV, and the Full Energy Peak Efficiency decreased by 10% for 1836. In addition, as it increased by 10 times, the Full Energy Peak Efficiency decreased by about 20% for 59.54 keV, and 7% for 1836.01 keV. The Penelope simulated Full Energy Peak Efficiency channel decreases exponentially with the increase in the four layers. In addition, it was confirmed that the total effect curve was well matched with a relative difference of less than 3.5% in the 0.3-1.4 mm dead layer thickness region. However, it was found that the inhomogeneous dead layer is still a parameter in the Monte Carlo model.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF