• 제목/요약/키워드: High pressure condition

검색결과 1,870건 처리시간 0.033초

궤도차량 현수장치 고압용 시일의 피로마모 개선 연구 (A Study on Fatigue Wear Improvement of High Pressure Seal for Tracked Vehicle Suspension)

  • 이용준;김형현;김경로;구융서
    • 한국군사과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.12-17
    • /
    • 2017
  • In this paper, causes of wear on high pressure seals for suspension are analyzed, and the result of reproduction test and verification on improved design are described. First, by performing the observation of worn surfaces and its failure analysis, the primary cause of wear on the seals are analyzed. The result of analysis shows that the main failure mechanism of wear is a fatigue wear, and test criteria for failure reproduction are set up with consideration for frequency condition, surface roughness and pressure. Durability comparison test on the condition of low amplitude and high frequency is carried out. And, it is found that the durability of wear on seals by increasing hardness of cylinder and managing for surface roughness is enhanced.

고압조건에서 기체-액체 분사기의 리세스에 따른 분무 특성 연구 (Study on Spray Characteristics of GCSC Injector with Recess in High Pressure Condition)

  • 김종규;한영민;최환석;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2011
  • GCSC 분사기의 리세스 길이와 기체/액체의 운동량 플럭스 비(MFR) 변화에 따른 분무 특성을 고압 챔버를 이용한 고압수류시험을 통해 알아보았다. 물과 질소를 사용하였고, back-lit strobe imaging 기법을 이용하여 분무형상을 촬영하였다. 시험결과 MFR이 작을 때(액체 유속 고정)는 분무각이 큰 hollow cone 형상을 보이고, MFR이 증가함에 따라 분무각이 작은 solid cone 형상의 분무를 보였다. 또한 리세스가 짧은 분사기일수록 더 큰 MFR에서 solid cone 형상의 분무를 보였다.

  • PDF

고압형 급수가열기 동체 감육 완화에 관한 연구 (A Study on the Relief of Shell Wall Thinning of High pressure Feedwater Heater)

  • 김형준;박상훈;서혁기;김경훈;황경모
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2664-2669
    • /
    • 2008
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line- inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

  • PDF

Development of High-Field ESR System Using SQUID Magnetometer and its Application to Measurement under High Pressure

  • Sakurai, T.;Fujimoto, K.;Okubo, S.;Ohta, H.;Uwatoko, Y.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.168-172
    • /
    • 2013
  • We have developed a high-field and high-frequency ESR system using a commercially available magnetometer equipped with the superconducting quantum interference device (SQUID). This is magnetization detection type ESR and ESR is observed as a change of the magnetization at the resonance condition under irradiation of the electromagnetic wave. The frequency range is from 70 to 315 GHz and the maximum magnetic field is 5 T. The sensitivity is estimated to be $10^{13}$ spins/G. The advantage of this system is that the high-field ESR measurements can be made very easily and quantitatively. Moreover, this high-field ESR can be applied to the measurements under pressure by using a widely used piston-cylinder pressure cell.

건설기계용 유압실린더 위치 제어시스템의 성능개선에 관한 연구 (A study on performance improvement of position control system in hydraulic cylinder for heavy construction machinery)

  • 한석재;박성환;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1450-1454
    • /
    • 1996
  • Even though digital control type high speed solenoid valve is a little inferior to analog control type servo valve and proportional control valve in performance, it is cheap and has secure performance against pollutant and simple control circuit. But high speed solenoid valve is hardly used for heavy machinery instead of servo valve or proportional control valve that is used in severe condition because the valve itself is small capacity and it shows wide dead zone during on-off control and chattering of hydraulic cylinder by chattering of pressure. It is desirable to use low-priced and strong pollutant resistant high speed solenoid valve for obtaining reliability of operation from severe working condition because it isn't necessary to acquire response characteristic of high frequency when we consider the characteristic of heavy machinery operation. In this study, PWM control algorithm for pilot pressure control of large capacity pilot operating valve will be used for precision position control of heavy machinery hydraulic cylinder. Not only cost reduction of main control valve but also high reliability of heavy machinery in severe condition can be obtained by using this pilot operating spool valve with high speed solenoid valve.

  • PDF

증기압을 고려한 플레인 저널 베어링의 동특성 변화 (Variation of the dynamic coefficients of the plain journal bearing considering vapor pressure)

  • 서준호;박재홍;임윤철
    • 정보저장시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 2012
  • Fluid dynamic bearings have several advantages that low noise, high rotational stability and low friction. So, early 2000s, the HDD spindle motors have been replaced ball bearings to fluid dynamic bearing. Most of studies apply inner boundary condition that is inside of bearing pressure larger than atmosphere pressure. Therefore, they used Half-Sommerfeld or Reynolds Boundary condition. This paper investigates the dynamic coefficients of the plain journal considered vapor pressure. As a result, it shows that the vapor pressure effect cannot ignore.

일 지역 성인의 고혈압 유병률 및 관리 실태 (A Study on the Prevalence Rate of Hypertension and the Actual Conditions of Control)

  • 김현옥
    • 지역사회간호학회지
    • /
    • 제10권1호
    • /
    • pp.154-172
    • /
    • 1999
  • In order to analyse the prevalence rate of hypertension and the actual conditions of control, we selected five districts out of eleven eups and myuns in Chinan Country. We administered structured questionaries to 309 adults above the age of 40, computerized the data using SPSS - PC+. More than 40.1% of adults over 40 in Chinan County have health disorders ranging from high blood pressure to hypertension including alert high blood pressure at 36.2%, relatively high. Among general characteristics, differences in the rate of hypertension were influenced by age, occupation and places of residence. Over 71 who are engaged in agriculture, who don't have jobs, who reside in Sungsu, Jungchun, Chinan-eup all have higher hypertension rates than other groups. Accordingly, the control of hypertension should be focused on these people. As a result of the control of blood pressure, the survey showed 93.0% of the subjects were checked mainly at hospitals clinics, health centers subhealth centers and community health posts more than once a year, relatively high level of blood pressure management. However, the difference between their blood pressure measurements at ordinary times and the level of blood pressure at the time of research was quite considerable. Only 47.3% of the subjects diagnosed with high blood pressure and 70.3% of the subjects with normal blood pressure recognized their blood pressure accurately 52.7% of the subjects diagnosed with high blood pressure showed errors in understanding their blood pressure at normal times. Because these errors can cause problems in the control of blood pressure, proper management should be executed through a systematic examination. As a result of the high blood pressure control condition, the average period of hypertension was 74.5( ${\pm}92.8$) months, 92.3% of the subjects were diagnosed with high blood pressure at hospitals clinics, health centers subhealth centers community health posts, but only 29.5% were examined after a general check up on high blood pressure was completed. 70.5% were diagnosed with high blood pressure only after measuring their blood pressure. 14.1% of the subjects were hospitalized because of falls influenced by high blood pressure. 33.3% attended hospitals and health centers regularily for medical treatment and this shows how low the rate of the control of blood pressure. Most people did not undergo medical treatment, because they had no painful symptoms (46.7%), they didn't need to take the medicine(28.9%), or they forget to take the medicine(20.0%). These problems in the control of hypertension were discovered in the process of diagnosing high blood pressure at health medical institutions. Many people did not recognize the need for consistent control of blood pressure. That is, although the diagnosis for high blood pressures performed at hospitals clinics, health centers subhealth centers and community health posts, was 92.3%, more than 70.5% of the subjects were not examined completely with regard to blood pressure. Accordingly, heath medical institutions must diagnose high blood pressure not only by only measuring blood pressure but also by using systematic process of examination. As for the people diagnosed with high blood pressure, one should perform consistent medical approaches and help them to recognize the importance of the continuous control of blood pressure through subject-oriented education. Problems the subjects experienced were the following numbness in the limbs easily paralyzed stitches in their shoulders which felt painful, stiff necks, occiputs felt heavy, headaches when they got up in the morning, felt dizzy when standing and moving their heads and poor eyesight. The rate of knowledge related to high blood pressure was 78.7 points, comparatively low. Whether they had normal blood pressure or hypertension made no difference. These results are not desirable. Adult-oriented education forgot the prevention and management of high blood pressure should be implemented. Hypertensive-oriented education should be especially reinforced. Because there was a difference in the level of knowledge according to age, academic career, occupation or place of residence, education related to hypertension should be intensified and focused on those over the age of 71 those who did not attend school, those who do not have jobs and are engaged in agriculture and residents living in Bugui, Jungchun regions. The degree of healthy life practice in hypertensives is poor, particularly weight control, as opposed to people who have normal blood pressure. It makes no difference in smoking, the amount of daily smoking, drinking, the control of salt because each result means that they are not practicing healthy life or modifying their life-style. The development and programs to improve a healthy life should be executed.

  • PDF

적층형 셀과 아연도금층을 이용한 고온고압 합성다이아몬드의 압력변화에 따른 물성 연구 (Property of the HPHT Diamonds Using Stack Cell and Zn Coating with Pressure)

  • 신운;송오성
    • 한국세라믹학회지
    • /
    • 제49권2호
    • /
    • pp.167-172
    • /
    • 2012
  • Fine diamond powders are synthesized with a 420 ${\phi}$ cubic press and stack-cell composed of Kovar ($Fe_{54}Ni_{29}Co_{17}$) (or Kovar+7 ${\mu}m$-thick Zn electroplated) alloy and graphite disks. The high pressure high temperature (HPHT) process condition was executed at $1500^{\circ}C$ for 280 seconds by varying the nominal pressure of 5.7~10.6 GPa. The density of formation, size, shape, and phase of diamonds are determined by optical microscopy, field emission scanning electron microscopy, thermal gravimetric analysis-differential thermal ammnlysis (TGA-DTA), X-ray diffraction (XRD), and micro-Raman spectroscopy. Through the microscopy analyses, we found that 1.5 ${\mu}m$ super-fine tetrahedral diamonds were synthesized for Zn coated Kovar cell with whole range of pressure while ~3 ${\mu}m$ super-fine diamond for conventional Kovar cell with < 10.6 GPa. Based on $750^{\circ}C$ exothermic reaction of diamonds in TGA-DTA, and characteristic peaks of the diamonds in XRD and micro-Raman analysis, we could confirm that the diamonds were successfully formed with the whole pressure range in this research. Finally, we propose a new process for super-fine diamonds by lowering the pressure condition and employing Zn electroplated Kovar disks.

소형가스루프 시험조건에서 소형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Small-Scale PHE Prototype under the Test Condition of Small-Scale Gas Loop)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2012
  • A PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. In order to properly evaluate the high-temperature structural integrity of the small-scale PHE prototype, it is very important to impose a proper constraint condition on its structural analysis model. For this effort, we tried to impose several constraint conditions on the structural analysis model and consequently fixed a proper and effective displacement constraints.

대구지역 CO농도에 미치는 기상효과에 관한 연구 (On the Meteorological Influence on the Automobile Air Pollution in Daegu)

  • 김해동;박명희;이정영
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.987-996
    • /
    • 2003
  • In this study, we analyzed the relationship between the time-variation trend of air pollution concentration index and the meteorological conditions with CO(carbon monoxide) concentration and meteorological observation data in high-CO episode days. CO is a representative automobile air pollutant. The results are as follows; 1. Most of the high-CO episode days within 30 classes appeared in winter season. 2. Most of them appeared under the surface weather conditions with east-west high-pressure system. The surface winds in this high-pressure area were very light. 3. The high-CO episode days were due to unusual accumulation within urban atmosphere in the morning. 4. The Atmospheric stabilities were more stable, and then the wind-ventilation conditions were worse than yearly mean atmospheric condition in Daegu.