A Study on the Relief of Shell Wall Thinning of High pressure Feedwater Heater

고압형 급수가열기 동체 감육 완화에 관한 연구

  • 김형준 (경희대학교 기계공학과) ;
  • 박상훈 (경희대학교 기계공학과) ;
  • 서혁기 (경희대학교 기계공학과 대학원) ;
  • 김경훈 (경희대학교 기계공학과, 산학협력 기술연구원) ;
  • 황경모 (한국전력기술(주) 재료기술연구그룹)
  • Published : 2008.11.05

Abstract

Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line- inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

Keywords