• Title/Summary/Keyword: High ozone concentration

Search Result 294, Processing Time 0.024 seconds

Development of Ozone Generating System Applying Forward Type High Voltage Pulse Power Supply (Forward형 고압펄스 전원장치를 적용한 오존발생 시스템 의 개발)

  • 김동희;원재선;김경식;이광식;정도영;오승훈
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.7
    • /
    • pp.335-342
    • /
    • 2003
  • This paper presents a forward type high voltage pulse power supply for high voltage small current, which can be designed as a simple circuit configuration and managed easily using Power-MOSFET in the view of commercialization. According to the switching frequency, coupling factor(k) and duty ratio(D), the Principle of basic operation and the characteristics of the proposed pulse power supply are estimated. Simulation results have demonstrated the feasibility of the proposed pulse power supply. Also experimental results are presented to verify theoretical discussion with a lamp type ozonizer as a load. For studying the application at the part of environment of water, When ozonizer gas reacts with a colon bacillus, the sterilization characteristics of a colon bacillus according to the ozone concentration and response time have been investigated. This proposed pulse power supply will be able to be practically used as a pulse power supply in various environment improvement facilities like sterilization of colon bacillus, deodorization, and Nox gas elimination.

Development of the Ozone Generator with Silent Discharge Type for Clean Environment (친환경적인 무성방전형 오존발생기 개발)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.562-564
    • /
    • 2000
  • The optimization of electrode geometry is the most important technology for producing the ozone with high concentration and efficiency. An optimization method for a discharge gap, an air cleaner equipment, voltage apply device, pressure and air flow quantity. In our experiments, the high frequency power were applied to the discharge gap with 23-1G(Silent Discharge). The ozone characteristics was measured with air as a supplied gas, which can be used as basic data for the development of small size ozone generator.

  • PDF

Ozone Generation Characteristics in Dielectric Barrier Discharge (유전체 장벽 방전내에서 오존발생 특성)

  • Lee, Hyeong-Ho;Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.673-678
    • /
    • 2000
  • The dielectric barrier discharge(DBD) is a common method to create a nonthermal plasma in which electrical energy is used to create electrons with a high average kinetic energy. The unique aspect of dielectric barrier discharges is the large array of short lifetime(10ns) silent discharges created over the surface of the dielectric. A silent discharge is generated when the applied voltage exceeds the breakdown voltage of the carrier gas creating a conduction path between the applied electrode and grounded electrode. As charge accumulates on the dielectric, the electric field is reduced below the breakdown field of the carrier gas and the silent discharge self terminates preventing the DBD cell from producing a thermal arc. In fact, the most significant application of dielectric barrier discharges is to generate ozone for contaminated water treatment. Therefore, experiments were perfomed at 1∼2[bar] pressure using a coaxial geometry single dielectric barrier discharge for ozone concentrations and energy densities. The main result show that the concentration and efficiency of ozone are influenced by gas nature, gas quantity, gas pressure, supplied voltage and frequency.

  • PDF

Estimate of Surface Ozone Concentration on Sunny Summer Days in Seoul Area by the Photochemical-Trajectory Model (광화학-궤적 모델에 의한 여름철 맑은 날 서울지방의 지상 오존 농도 추정)

  • 이시우;이광목
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.497-506
    • /
    • 2002
  • A Photochemical-Trajectory model was used to understand the production of ozone in the atmospheric boundary layer. This model was composed of the trajectory and the photochemical models. To calculate trajectories of air parcels, winds were obtained from the three-dimensional nonhydrostatic mesoscale model (PSU/NCAR MM5V2), and the results were interpolated into constant height surfaces. Numerical integration in the trajectory model was performed by the Runge-Kutta method. The photochemical model consisted of chemical reactions and photodissociation processes. Chemical equations were integrated by the semi-implicit Bulirsch-Stoer method. We performed our experiments from 21 July to 23 July 1994 during the summer time for Seoul area. During the time of maximum ozone concentration in Seoul, four trajectories of air parcels which traveled from Inchon to Seoul were selected. Ozone concentrations estimated by two models are compared with observed one in Seoul area and the photochemical-trajectory model is better fitted than pure photochemical model. During the selected period, high ozone concentrations in Seoul area were more influenced by transferred pollutants from Inchon than emitted pollutants in Seoul.

Quantitative Assessment on Contributions of Foreign NOx and VOC Emission to Ozone Concentrations over Gwangyang Bay with CMAQ-HDDM Simulations (CMAQ-HDDM을 이용한 광양만 오존 농도의 국외 기여도 분석)

  • Bae, Changhan;Kim, Byeong-Uk;Kim, Hyun Cheol;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.708-726
    • /
    • 2018
  • In this study, we examined the contribution of nitrogen oxides and volatile organic compounds emitted from China and Japan to ozone concentrations over Gwangyang-bay, South Korea. We used a chemical transport model, Community Multi-scale Air Quality model, and its instrumented sensitivity tool, High-order Decoupled Direct Method. Intercontinental Chemical Transport Experiment-Phase B 2006 for East Asia and Clean Air Policy Support System 2007 emissions inventories for South Korea were used for the ozone simulation. During the study period, May 2007, the modeled maximum daily 8-hr average ozone concentration among seven air quality monitors in Gwangyang-bay was 68.8 ppb. The contribution of $NO_x$ emissions from China was 19.5 ppb (28%). The highest modeled ozone concentrations and Chinese contributions appeared when air parcels were originated from Shanghai area. The observed 8-hr average ozone concentrations in Gwangyang Bay exceeded the national ambient air quality standard (60 ppb) 203 times by daytime and 56 times by nighttime during the period. It was noticed that many exeedances happened when contribution of Chinese emissions to ozone concentrations over the area increased. Sensitivity analysis shows that a reduction in Chinese $NO_x$ and VOC emissions by 15% could lessen the total exceedance hours by 24%. This result indicates that high ozone concentrations over Gwangyang-bay are strongly enhanced by Chinese emissions.

Characteristics of Air Pollution at Kimhae (김해지방의 대기오염 특성)

  • 박종길;김종필;김지형
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.33-43
    • /
    • 1999
  • This paper aims to describe the characteristics of air pollution using air pollutants concentration and meteorological data observed at Kimhae from December 1996 to November, 1997. The results are as follows : The concentration distribution of sulfur dioxide($SO_2$), carbon monoxide(CO), particulate matter(PM-10), and nitrogen dioxide($NO_2$) is high during the late fall and winter and low during the summer, but ozone concentration is low during the winter season and high during summer season except Jangma period and these distributions appear to be closely connected with insolation and the number of clear day. Diurnal variation of concentrations for sulfur dioxide, particulate matter, and carbon monoxide are high during the rush hours and nighttime and low during the daytime and these variations are distinct toward the winter season. And diurnal variation of nitrogen dioxide concentration has also same pattern and these patterns are closely related to the increasing traffic volume at rush hours. Diurnal variation of ozone concentration is generally increase for daytime and decrease for the late afternoon and are closely related to the insolation and photochemical reaction. The 24 hour average concentrations of air pollutant observed at Kimhae represented a positive correlation and a negative correlation for $O_3$ and also a negative correlation for the meteorological elements such as wind speed and cloud cover.

  • PDF

A Design Technology of Ceramic Tube for High Efficiency Ozone

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Dong-Hoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.77-80
    • /
    • 2003
  • An innovative ozonizer has been developed using a high frequency, surface discharge and a high purity Ti-Si-AI ceramic catalyst as a dielectric component. Using a type of thin film, a thin cylindrical compound ceramic catalyst layer was adhered to the outside surface of its inner electrode. An alternating current (AC) exciting voltage with frequencies from 0.6 KHz to 1.0 KHz and peak-to-peak voltages of 4-6 ㎸ was applied between the electrodes to produce a stable high-frequency silent discharge. A substantial reduction of the exciting voltage was also enabled by means of a thin Ti-Si-Al ceramic catalyst tube. As a result, the ozonizer can effortlessly obtain the required ozone concentration (50-60 g/$m^2$ for oxygen) and high ozone efficiency consumption power (180 g/kWh for oxygen) with-out the assistance of any particular methods. For purposes of this experiment, oxygen gas temperature was set at 2$0^{\circ}C$, with an inner reactor pressure of 1.6 atm at 600 Hz and a flow rate of 2 l/min.

Evaluation of Ozone for Oxide Superconductor Thin Film Fabrication (산화물 초전도 박막 제작을 위한 오존의 평가)

  • Lim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1230-1233
    • /
    • 2004
  • Ozone is useful oxidizing gas for the fabrication of oxide thin films. Accordingly researching on oxidizing gas is required. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper oxidation property was evaluated relation between oxide gas pressure and inverse temperature(CuO reaction). The obtained condition was formulated by the fabrication of Cu metal thin film by co-deposition using the ion Beam Sputtering method. Because the CuO phase peak appeared at the XRD evaluation of the CuO thin film using ozone gas, this study has succeeded in the fabrication of the CuO phase at $825^{\circ}C$.

  • PDF

Evaluation of Oxidation Ozone for Superconductor Thin Film Growth (초전도 박막 제작을 위한 산화 오존의 평가)

  • Lim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.35-38
    • /
    • 2004
  • Ozone is useful oxidizing gas for the fabrication of oxide thin films. Accordingly researching on oxidizing gas is required. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper oxidation property was evaluated relation between oxide gas pressure and inverse temperature(CuO reaction). The obtained condition was formulated by the fabrication of Cu metal thin film by co-deposition using the Ion Beam Sputtering method. Because the CuO phase peak appeared at the XRD evaluation of the CuO thin film using ozone gas, this study has succeeded in the fabrication of the CuO phase at $825^{\circ}C$.

  • PDF

The Characteristics of Discharge and Ozone Concentration for plate type ozonizer with Discharge Area variation (평판형 오존발생기의 방전면적에 따른 방전 및 오존생성특성)

  • Lee, Chang-Ho;Lee, Sang-Keubn;Song, Hyun-Jig;Kim, Jong-Hyun;Youn, Byung-Han;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.346-349
    • /
    • 2007
  • In this paper, the ozonizer is equipped with three electrodes ( two external electrodes, central electrode ), and AC high voltage which has 180[$180^{circ}C$] phase difference is applied to two H V. Ozone discharge and generation charactristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power. Ozone concentration, generation and yield were proportionally increased with increasing discharge area size.

  • PDF