• Title/Summary/Keyword: High ozone

Search Result 664, Processing Time 0.031 seconds

A Numerical Simulation of High Ozone Episode Using OZIPR in Busan (OZIPR을 이용한 부산지역 고농도 오존 사례 모사)

  • Do, Woo-Gon;Lee, Hwa-Woon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.985-994
    • /
    • 2007
  • To investigate the effect of NOx and VOCs(volatile organic compounds) on the generation of high ozone episode, examined the hourly variations of ozone, NOx and VOCs concentrations, and calculated the ozone isopleth about maximum ozone concentrations using OZIPR which was presented by U. S. EPA at three sites in Busan. There was some difference by the sites, but decreasing VOCs concentration was effective for reduction of ozone at 22 July, the episode day of 2005. In the year 2006, the episode day was 8 August and the variations of NOx and VOCs concentration was little than variation of ozone. So it was estimated that the photochemical production of ozone was low than transportation of ozone. And the result of the OZIPR modeling was that decreasing VOCs concentration was effective for reduction of ozone.

Optical Fiber Atmospheric Ozone Monitor (광섬유 대기오존 모니터)

  • 정완영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.201-204
    • /
    • 2002
  • A high accuracy ozone monitor using UV absorption method was developed for ambient ozone monitoring. The system was mainly composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit. The optical signal from the CCD array that provides unusually high response and excellent optical resolution for ozone concentration was converted to digital signal and the digital signal was displayed on screen using PC interface. The optical signal was propagated using optic fiber to reduce optical loss to increase the accuracy of the measuring system. This paper has been studied a interworking signalling protocol between two hybrid networks by analyzing Satellite B-ISDN architecture, DSS2 Layer 3 Signalling protocol, B-ISUP protocol, S-BISUP protocol stack and so on. Also in the paper, messages and primitives have been defined for B-ISDN's Connection Type, Ownership and each protocol in order to connect point-to-multipoint. The ozone sensing properties of the CCD ozone monitor was compared with those of the photo multiplier ozone monitor.

  • PDF

High Efficiency Photoresist Strip Technology by using the Ozone/Napor Mixture (오존/증기 혼합물을 이용한 고효율 반도체 감광막 제거기술)

  • Son, Young-Su;Ham, Sang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.22-23
    • /
    • 2006
  • A process for removal of photoresist(PR) m semiconductor manufacturing using water vapor with ozone is presented. For the realization of the ozone/vapor mixture process, high concentration ozone generator and process facilities have developed. As a result of the silicon wafer PR strip test, we confirmed the high efficiency PR strip rates of 400nm/mm or more at the ozone concentration of 16wt%/$O_2$. The ozone/vapor mixture process is more effective than the ozonized water Immersion process.

  • PDF

Surface Ozone in The Major Cities of Korea : Trends, Diurnal and Seasonal Variations, and Horizontal Distributions (한반도 주요 대도시지역의 지표오존 특성 : 추세, 일변화, 월변화, 수평분포)

  • 오인보;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.253-264
    • /
    • 2002
  • Surface ozone concentrations measured at 40 monitoring sites in three major cities (Seoul, Busan, and Daegu) of Korea during 1993~2000 were analyzed to understand the characteristics of temporal and spatial distributions. Trends were analyzed for annual mean, 95th percentiles of daily 8-hour maximum and days exceeding 8-h ozone standard of 60 ppb. Three indicators exhibited increasing trends (+0.75 ppb yr$^{-1}$ , +2.20 ppb yr$_{-1}$ , and +5.35 days yr$_{-1}$ on average) throughout the study period at all cities. Diurnal and seasonal variations were the largest in Seoul followed by Daegue and Busan, due to the high photochemical production and titration of ozone (Seoul), strong wind and constant supply of background ozone from the ocean (Busan). In the urban centers and industrial areas at all cities, scavenging of ozone by NO reduces the daily 8-hour maximum ozone by 10 ppb on average. High concentrations of ozone have frequently occurred in downwind eastern (Seoul and Daegu) or northern (Busan) sides of the territory. In particular, the coastal area of Busan had relatively high ozone level due to the local sea land breeze circulation. The results indicated that the temporal and spatial variations of ozone concentration were non -uniform and were closely related to the local environments; emission levels, climates, and geographic locations.

Effects of Corona Electrode Shape and Discharge Gap Spacing on Ozone Concentration (방전공격과 방전극 형상이 오존발생농도에 미치는 영향)

  • Park, Seung-Lok;Lee, Jae-Chan;Jung, Sung-Jin;Moon, Jae-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.169-175
    • /
    • 2001
  • Ozone has been widely applied to many industrial fields because of its strong oxidation power, Therefore, the studies have been carried out for the methods on an effective and high concentration ozone generation. The silent or surface discharge type ozone generators have been mainly used for high concentration ozone generation in many fields of applications. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above ozone generators was proposed and fabricated for the high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrode was proposed and studied as a function of the widths output maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], for 0.3[mm] width and 0.8[mm] vacancy of the mesh electrode and gap spacing of 0.65[mm] respectively.

  • PDF

The Influence of Long-range Transport on Springtime Nocturnal Ozone Enhancement in Seoul (봄철 서울지역 야간 오존농도 상승에 미치는 장거리 수송의 영향)

  • 오인보;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.503-514
    • /
    • 2004
  • In Seoul metropolitan area, nocturnal variation of surface ozone concentrations observed at 27 monitoring sites from 1998 to 2002 showed that high ozone levels occurred frequently during the spring. Frequency distributions for nighttime ozone indicated that elevated concentrations in spring were influenced by advection of different air mass compared to other seasons. Surface wind analysis during the spring revealed that relatively strong southwesterly winds were associated with nocturnal ozone enhancement, which can be attributed to the regional transport of ozone. In order to identify the origin of nocturnal ozone enhancement in spring, 3-day backward trajectories were calculated by HYSPLIT 4 for the episode days and then classified. The results showed that NW, W, and SW flows, indicating influence of polluted air masses from the China continent, have 51% in a]1 the episode days, which suggest that the nocturnal ozone enhancement can occur under the effect of long-range transport of ozone-laden air mass on a regional scale. Case study of nocturnal ozone maxima associated with long-range transport was discussed in more detail in the light of meteorological conditions. Southwesterly synoptic flow along the outer edge of moving high-pressure system was found to be the important cause of nocturnal ozone maxima in Seoul. This flow could lead to be long-range transport of ozone that had effectively accumulated in the stagnating portion of the system located eastern coast of China. Low atmosphere soundings, backward trajectories, and elevated ozone and CO levels at the back-ground tiles gave evidence for regional effects on nocturnal ozone enhancement In Seoul.

Design and Development of a High-Voltage Transformer-less Power Supply for Ozone Generators Based on a Voltage-fed Full Bridge Resonant Inverter

  • Amjad, Muhammad;Salam, Zainal;Facta, Mochammad;Ishaque, Kashif
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.387-398
    • /
    • 2012
  • It is known that transformer based power supplies for ozone generators have low efficiency, high cost and exhibits a limited frequency range of operation. To overcome these disadvantages, this paper proposes a high frequency ozone generator with the absence of a transformer. The voltage step-up is achieved only by utilizing the resonant tank. This is made possible by a novel combination of ozone chamber materials that allow ozone to be generated at only 1.5 - 3.5 $kV_{p-p}$. The input to the resonant tank is driven by a PWM full bridge resonant inverter. Furthermore, zero-current zero-voltage switching (ZCZVS) operation is achieved by employing a duty factor of 25% between the switches of the full bridge. The advantages of the proposed system include high efficiency, low cost and the ability to control ozone production by varying the input voltage to the inverter. The prototype is verified by both simulation and experimental results.

Construction and Evaluation of $O_3$ Condensation System for Oxide Thin Film (산화 박막 성장을 위한 $O_3$ 농축 시스템의 구축 및 평가)

  • Lim, Jung-Kwan;Ryu, Sun-Jong;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1192-1195
    • /
    • 2003
  • A highly condensed ozone gas be transferred to the superconductor thin film growth chamber because ozone is strong oxidizing gas. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure.

  • PDF

Distribution of Tropical Tropospheric Ozone Determined by the Scan-Angle Method applied to TOMS Measurements

  • Kim, Jae-H.;Na, Sun-Mi;Newchurch, M. J.;Emmons, L.
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.7-11
    • /
    • 2002
  • This study introduces the first method that determines tropospheric ozone column directly from a space-based instrument. This method is based on the physical differences in the Total Ozone Mapping Spectrometer (TOMS) measurement as a function of its scan-angle geometry. Tropospheric ozone in September-October exhibits a broad enhancement over South America, the southern Atlantic Ocean, and western South Africa and a minimum over the central Pacific Ocean. Tropical tropospheric ozone south of the equator is higher than north of the equator in September-October, the southern burning season. Conversely, ozone north of the equator is higher in March, the northern burning season. Overall, the ozone over the southern tropics during September-October is significantly higher than over the northern tropics. Abnormally high tropospheric ozone occurs over the western Pacific Ocean during the El Nino season when the ozone amounts are as high as the ozone over the Africa.

  • PDF

Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation (고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화)

  • Lee, Jin-kook;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.171-180
    • /
    • 2016
  • This study was to evaluate the change in characteristics of concentration of ozone after exposure to high energy radiation in linac room. Background ozone concentration of linac room was measured and compared to ozone concentration around linac room. Background ozone concentration of linac room was mean $17.4{\pm}7.9ppb$. It was 50% of the ozone concentration($36.8{\pm}22.3ppb$) around linac room(p<0.05). The concentration of ozone after exposure to high energy radiation in linac room was elevated to double of background ozone level, intensity after exposure. with exposure time concentration of ozone increased proportionally. It showed maximum level at 130~180seconds and slowed a tendency to saturate. It required more than 10 minutes for ozone concentration in linac room to drop to ozone concentration around linac room. The concentration of ozone after exposure to high energy radiation is high enough to cause specific physical symptoms, such as acute dyspnea or chest pain due to dry cough. Exposure to high concentration of ozone in sealed linac room can aggravate pulmonary disease, so special attention is needed.