• Title/Summary/Keyword: High ozone

Search Result 664, Processing Time 0.026 seconds

Characteristics of Oxidizing Gas for BSCCO Thin Film Fabrication (BSCCO 박막 제작을 위한 산화가스의 특성)

  • Lim, Jung-Kwan;Park, Yong-Pil;Jang, Kyung-Uk;Lee, Hee-Kab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.110-113
    • /
    • 2005
  • Ozone is useful oxidizing gas for the fabrication of BSCCO thin films. In order to obtain high quality oxide BSCCO thin films, higher ozone concentration is necessary. The growth rates of the films was set in the region from 0.17 to 0.27 nm/min. MgO(100) was used as a substrate. In this paper oxidation property was evaluated relation between oxide gas pressure and inverse temperature(CuO reaction). The obtained condition was formulated by the fabrication of Cu metal thin film by co-deposition using the Ion Beam Sputtering method. Because the CuO phase peak appeared at the XRD evaluation of the CuO thin film using ozone gas, this study has succeeded in the fabrication of the CuO phase at $825^{\circ}C$.

  • PDF

Characteristics of Ambient Gas for Bi-Superconductor Thin Films Growth (Bi 초전도 박막 성장을 위한 분위기가스의 특성)

  • Lim, Jung-Kwan;Park, Yong-Pil;Jang, Kyung-Uk;Lee, Hee-Kab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.587-588
    • /
    • 2005
  • Ozone is useful oxidizing gas for the fabrication of BSCCO thin films. In order to obtain high quality oxide BSCCO thin films, higher ozone concentration is necessary. The growth rates of the films was set in the region from 0.17 to 0.27 nm/min. MgO(100) was used as a substrate. In this paper oxidation property was evaluated relation between oxide gas pressure and inverse temperature(CuO reaction). The obtained condition was formulated by the fabrication of Cu metal thin film by co-deposition using the Ion Beam Sputtering method. Because the CuO phase peak appeared at the XRD evaluation of the CuO thin film using ozone gas, this study has succeeded in the fabrication of the CuO phase at $825^{\circ}C$.

  • PDF

Meteorological Characteristics related to the Variation in Ozone Concentrations before, during, and after the Typhoon Period in the Korean Peninsula (한반도 태풍영향 전·중·후 시기동안 오존농도 변화에 관한 기상특성 분석)

  • Shin, Hyeonjin;Song, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.26 no.5
    • /
    • pp.621-638
    • /
    • 2017
  • Meteorological characteristics related to variations in ozone ($O_3$) concentrations in the Korean peninsula before, during, and after Typhoon Talas (1112) were analyzed using both observation data and numerical modeling. This case study takes into account a high $O_3$ episode (e.g., a daily maximum of ${\geq}90ppb$) without rainfall. Before the typhoon period, high $O_3$ concentrations in the study areas (e.g., Daejeon, Daegu, and Busan) resulted from the combined effects of stable atmospheric conditions with high temperature under a migratory anticyclone (including subsiding air), and wind convergence due to a change in direction caused by the typhoon. The $O_3$ concentrations during the typhoon period decreased around the study area due to very weak photochemical activity under increased cloud cover and active vertical dispersion under a low pressure system. However, the maximum $O_3$ concentrations during this period were somewhat high (similar to those in the normal period extraneous to the typhoon), possibly because of the relatively slow photochemical loss of $O_3$ by a $H_2O+O(^1D)$ reaction resulting from the low air temperature and low relative humidity. The lowest $O_3$ concentrations during the typhoon period were relatively high compared to the period before and after the typhoon, mainly due to the transport effect resulting from the strong nocturnal winds caused by the typhoon. In addition, the $O_3$ increase observed at night in Daegu and Busan was primarily caused by local wind conditions (e.g., mountain winds) and atmospheric stagnation in the wind convergence zone around inland mountains and valleys.

Trial Manufacture and Characteristics of a Multi-discharge Type ozonizer(I) (다중방전형 오존발생기의 試作 및 特性(I))

  • Song, Hyeon-Jik;Lee, Gwang-Sik;Park, Won-Ju;Lee, Dong-Heon;Kim, Geum-Yeong;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.533-541
    • /
    • 1999
  • Multi-discharge type ozonizer(MDO) using superposed silent discharge has been designed and manufactured. It consists of three electrodes( central electrode, internal electrode, and external electrode ) and double gaps( gap between central electrode and internal electrode, gap between internal electrode and external electrode ). Therefore, ozone is generated by superposing silent discharges generated between the gaps respectively. And the MDO consists of three types of superposed discharge ozonizers according to voltage appling method for each electrode ; A.C. high voltages are applied two of three electrodes with phase difference of 180[˚], the other electrode is a ground. This paper describes that discharge and ozone generation characteristics of MDO which comprising central electrode and internal electrode applied A.C. high voltages with phase difference of 180[˚] respectively, and the grounded external electrode. As a result, the maximum ozone concentration, generation, and yield can be obtained 10208[ppm], 6.4[g/h], and 280[g/kwh] respectively.

  • PDF

Development of a Garlic Peeling System Using High-Pressure Water Jets (III) - Introduction of a microbial control system - (습식 마늘박피 시스템 개발 (III) - 미생물 제어 시스템의 도입 -)

  • Kim J.;Bae Y. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.17-24
    • /
    • 2005
  • An efficient microbial control system was introduced into a garlic peeling system using pressurized water in order to improve the quality and the shelf-life of peeled garlic. High microbial density of the spoiled peeled garlic and the water used for peeling and washing indicated that an efficient microbial control system is necessary far the peeling system. Though Pseudomonas spp. and Penicillium spp. were closely related to the spoilage of peeled garlic, the spoilage of peeled garlic was thought to be caused mainly by nonspecific increase in microbial density. The shelf-life of the garlic peeled by pressurized water was longer than that of the garlic peeled by pressurized air, and the degree of damage had great effect on the shelf-life of peeled garlic. Ozonated water was effective in decreasing the microbial contamination and in increasing the shelf-life of peeled garlic. Based on the findings of the study, following improvements were made to the garlic peeling system using pressurized water; 1) the water circulation system was modified in order to completely separate the water for washing from the water for garlic peeling, 2) filtration and cooling equipments were introduced into the circulation system of the water for peeling, and 3) an ozone generator which could continuously supply ozonated water (dissolved ozone concentration of 0.4 ppm) was attached to the circulation system of the water for washing.

Design of Double Digital Controller to Improve Performance for the Silent Discharging Ozonizer (무성방전 오조나이저의 성능개선을 위한 2중 디지털 제어기의 설계)

  • Park, Jee-Ho;Kim, Dong-Wan;Woo, Sung-Hoon;Roh, In-Bae;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • In this paper, a control method of ozone generator for a tiny deodorizer is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2[^{\circ}C]$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the respond characteristics with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.

지중오존산화시 토양유기물질과 수분이 토착미생물의 생존과 재성장에 미치는 영향

  • 손규동;정해룡;최희철;김수곤;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.334-337
    • /
    • 2003
  • This study was carried out to investigate the effect of soil properties, such as soil organic matter(SOM) content and water content on die-off and regrowth of indigenous microbes due to in-situ ozonation. Four different soils were collected and the soil samples applied to different ozonation time(0-360 min) were incubated during 4 weeks. Population of the indigenous microbes was monitored during incubation period. The number of indigenous microbes in all samples dramatically decreased (more than 90%) within 30 minutes of ozone injection. With increased ozonation time by 360 minutes, the number of the indigenous microbes decreased by 99.99% in all samples. Die-off of the indigenous microbes due to ozone treatment was inversely proportional to SOM and water content. Especially, sample 3 and Sample 4 containing relatively high SOM content and water content showed high regrowth rate, and this resulted from the increase of water soluble and biodegradable organic fraction in soil water after ozone treatment. Soil sample ozonated for 360 minutes showed minor increase in microbial population during 4 weeks of incubation period.

  • PDF

Characteristic behaviors of ozone decomposition and oxidation of pharmaceuticals during ozonation of surface waters in Ulsan (울산시 상수원수에서의 오존분해 특성 및 의약물질 분해 거동 연구)

  • Lee, Hye-Jin;Lee, Hongshin;Lee, Changha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2013
  • This study demonstrates the oxidative degradation of pharmaceutical compounds during ozonation of surface waters in Ulsan. Diclofenac, carbamazepine, bezafibrate, and ibuprofen were selected as surrogate pharmaceutical compounds, and ozonation experiments were performed using raw waters collected from the Sayeon Dam and the Hoeya Dam in Ulsan. Diclofenac and carbamazepine which have high reactivity with molecular ozone showed higher removal efficiencies than bezafibrate and ibuprofen during ozonation. The addition of tert-butanol, a hydroxyl radical scavenger, increased the removal efficiencies of diclofenac and carbamazepine by increasing the ozone exposure. However, the oxidation of bezafibrate and ibuprofen was inhibited by the presence of tert-butanol due to the suppression of the exposure to hydroxyl radical. The elimination of the selected pharmaceuticals could be successfully predicted by the kinetic model base on the $R_{ct}$ concept. Depending on the experimental condition, $R_{ct}$ values were determined to be $(1.54{\sim}3.32){\times}10^{-7}$ and $(1.19{\sim}3.04){\times}10^{-7}$ for the Sayeon Dam and the Hoeya Dam waters, respectively. Relatively high $R_{ct}$ values indicate that the conversion of $O_3$ into $^{\cdot}OH$ is more pronounced for surface waters in Ulsan compared to other water sources.

Characteristics of high concentration. yield multi discharge type ozonizer for dyeing water treatment (염색폐수 처리용 고농도.고수율 다중방전형 오존발생기의 특성)

  • Lee, Dong-Heon;Song, Hyun-Jig;Lee, Sang-Geun;Lee, Dong-Wook;Park, Won-Zoo;Lee, Kwang-Sik;Jean, Young-Ju;Kim, Sang-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2141-2143
    • /
    • 2000
  • In this paper, high concentration yield multi-discharge type ozonizer (MDO) of new discharge type using superposed silent discharge was designed and manufactured, MDO can be consisted with 3 kind of multi discharge type ozonizer (MDO) in accordance with power supply method that supplying power, which has 180[$^{\circ}$] phase difference, to 3 electrodes and double gap. At the moment, discharge characteristics and ozone generation characteristics of each MDO were investigated in accordance with quantity of supplied gas, the number of MDO, and the shapes of each MDO. In result, ozone generation characteristics of 17185[ppm] and 783[g/kWh] were obtained, and when ozone of 17185 [ppm] was in contact with dyeing water waste, decolorization characteristics was excellent, so it confirmed that MDO could be used as water environment improvement facility.

  • PDF