• 제목/요약/키워드: High organic loading wastewater

검색결과 89건 처리시간 0.033초

Membrane-Attached Biofilm Reactor(MABR)에서의 독립영양 미생물을 이용한 질소 제거 (Nitrogen Removal using Autotrophic Microorganism in Membrane-Attached Biofilm Reactor (MABR))

  • 신정훈;상병인;정윤철;정연규
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.624-629
    • /
    • 2005
  • The purpose of this study is to investigate the performance of nitrogen removal using autotrophic microorganism in the Membrane-Attached Biofilm Reactor (MABR). The treatment system consists of an aerobic MABR (R1) for nitrification and an anaerobic MABR (R2) for hydrogenotrophic denitrification. Oxygen and hydrogen were supplied through the lumen of hollow-fiber membranes as electron acceptor and donor, respectively. In phase Ι, simultaneous organic carbon removal and nitrification were carried out successfully in R1. In phase II, to develop the biofilm on the hollow-fiber membrane surface and to acclimate the microbial community to autotrophic condition, R1 and R2 were operated independently. The MABRs, R1 and R2 were connected in series continuously in phase III and operated at HRT of 8 hr or 4 hr with $NH_4{^+}-N$ concentration of influent, from 150 to 200 mgN/L. The total nitrogen removal efficiency reached the maximum value of 99% at the volumetric nitrogen loading rate of $1.20kgN/m^3{\cdot}d$ in the combined MABR system with R1 and R2. The results in this study demonstrated that the combined MABR system could operate effectively for the removal of nitrogen in wastewater not containing organic materials and can be used stably as a high rate nitrogen removal technology.

UASB 공정에 의한 슬러리형 돈사폐수의 처리 (The Treatment of Slurry-type Swine Waste using UASB Reactor)

  • 원철희;김병욱;한동준;임재명
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.583-588
    • /
    • 2004
  • This research examined the treatment efficiency and methane production rate in treating slurry-type swine waste using UASB (upflow anaerobic sludge blanket) reactor. The UASB reactor was operated at an organics volumetric loading rate (VLR) of $2.6-15.7kgCOD/m^3/day$. A stepwise increase of the VLR resulted in a temporary deterioration in the COD removal rate in UASB reactor but recovered quickly. The COD removal rate were 65-70% for VLR up to $5 kgCOD/m^3/day$. When organics VLR was $10kgCOD/m^3/day$, the COD removal rate decreased sharply and there was loss of 17.537g of the seeding biomass due to sludge washout. This result indicated that the UASB system cannot be adapted to more than $10kgCOD/m^3/day$ of VLR. As the organic load increased from 2.6 to $15.7kgCOD/m^3/d$, the biogas production rate varied from 3.2 to 10.8 L/d and the methane conversion rate of the organic matter varied from 0.30 to $0.23m^3CH_4/kg\;COD_{removed}$. The methane content showed the range of 70.1-81.5% during the experimental period. The volatile solids (VS) removal efficiency was similar at the low VLR (< $5 kgCOD/m^3/day$), but it decreased sharply at the high VLR (> $5 kgCOD/m^3/day$). The VS reduction rate was, moreover, large those of COD. The result shows that hydraulic retention time above 2 days is essential in case of treating wastewater containing 1% of solids.

철전기분해장치(FNR)에서 단위공정에 따른 질소와 인의 제거 (A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process)

  • 김수복;김영규
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.83-89
    • /
    • 2013
  • Objectives: The purpose of this experiment was to illuminate the relationship between the phosphorus removal rate of unit operation and the phosphorus removal rate of phosphorus volume loading in the Ferrous Nutrient Removal process, which consists of an anoxic basin, oxic basin, and iron precipitation apparatus. Methods: This study was conducted in order to improve the effect of nitrogen and phosphorus removal in domestic wastewater using the FNR (Ferrous Nutrient Removal) process which features an iron precipitation reactor in anoxic and oxic basins. The average concentration of TN and TP was analyzed in a pilot plant ($50m^3/day$). Results: The removal rate of T-N and T-P were 66.5% and 92.8%, respectively. The $NH_3-N$ concentration of effluent was 2.62 mg/l with nitrification in the oxic basin even though the influent was 17.7 mg/l. The $NO_3$-N concentration of effluent was 5.83 mg/l through nitrification in oxic basin even though the influent and anoxic basin were 0.82 mg/l and 1.00 mg/l, respectively. The specific nitrification of the oxic basin ($mg.NH_3$-Nremoved/gMLVSSd) was 16.5 and specific de-nitrification ($mg.NO_3$-Nremoved/gMLVSSd) was 90.8. The T-P removal rate was higher in the oxic basin as T-P of influent was consumed at a rate of 56.3% in the anoxic basin but at 90.3% in the oxic basin. The TP removal rate (mg.TP/g.MLSS.d) ranged from 2.01 to 4.67 (3.06) as the volume loading of T-P was increased, Conclusions: The test results showed that the electrolysis of iron is an effective method of phosphorus removal. Regardless of the temperature and organic matter content of the influent, the quality of phosphorus in the treated water was both relatively stable and high due to the high removal efficiency. Nitrogen removal efficiency was 66.5% because organic matter from the influent serves as a carbon source in the anoxic basin.

침지형 분리막을 사용한 오수처리

  • 최광호
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.113-133
    • /
    • 1998
  • In activated sludge process, sludge settling condition is affected by organic loading rate or operation condition, and if settling condition is getting worse, it is common that overall process fails due to wash-out of biomass causing low concentration in the aeration tank. Also activated sludge process has such several problems as requiring large area, consuming a lot of power and producing large volume of sludge. Increased public concern over health and the environment combined with a strong desire to reduce capital, operating and maintenance costs, have created a need for innovative technologies for building new high quality effluents which vail meet 21st century crkeria. MBR(Membrane Bioreactor) process consists of a biological reactor and ultrafiltration(UF) membrane system that replaces the conventional clarifier of an activated sludge process. The main operating advantages of this system are that the quality of the effluent is independent of the settleability of the mixed liquor and that the effluent is free of suspended solids in any operating condition. It is possible to eliminate clarifier and to reduce the volume of aeration tank because it can afford to accumulate high biomass concentration in the bioreactor(20, 000~30, 000mg/L), which would not be possible in a conventional activated sludge process. Therefore, this process reduces overall treatment plant area. In addition to those advantages, Longer SRT condition enables higher sludge digestion in MBR process so the sludge volume produced is 50 to 70% lower than that of conventional activated sludge process There are two kinds of MBR process according to the allocations of membrane. One is cross flow type MBR of which module is located outside of the bioreactor and mixed liquor is driven into the membrane module. The other is submerged type MBR process of which module is submerged in the bioreactor and mixed liquor is generally sucked from the lumen side. addition to that the cake layer is often removed by the uplifting flow of bubbling air. A submerged MBR process is superior to a crossflow MBR in regard to the power consumption because suction pressure of a submerged MBR is generally lower than that of a crossflow MBR which has recirculation pump. A submerged MBR, therefore, has the potential to be applied to small wastewater treatment plants that need low cost treatment systems.

  • PDF

낙동강수계에서 섬유염색 및 가공 업체에 대한 공정별 원단위산정 및 분석 (Unit Mass Estimation and Analysis from Fiber Dyeing and Finishing Facility Nearby Nakdong River Basin)

  • 구정은;나동훈;이승환
    • 대한환경공학회지
    • /
    • 제31권9호
    • /
    • pp.765-774
    • /
    • 2009
  • 섬유염색 및 가공산업은 용수요구량이 매우 높은 편이며 다양한 난분해성 염료의 사용으로 인해 폐수발생량의 기여도가 높은 전형적인 오염 유발 산업이다. 본 연구는 낙동강 수계에서 산업폐수 발생업체 중 섬유염색 및 가공 산업시설을 중심으로 SS, $BOD_5,\;COD_{Mn},\;COD_{Cr}$, TN 그리고 TP와 같은 수질 항목에 대해서 발생원 단위 오염물질 배출 특성을 파악하고 발생원단위 부하량을 산출하기 위해 수행되었다. 각 산업을 대표하는 오염원 발생원단위의 산정을 위해 낙동강 수계에 산재한 섬유염색 및 가공업체 중 세 개 업체를 선정하였다. BOD 기준 유입수와 유출수에서의 원단위 값은 90%이상 감소하였지만 원수에서의 높은 유기물 부하량으로 인해 원단위값 자체는 섬유제조시설에서 얻어진 값과 유사하였다. 유수의 생분해도는 유출수에 비해 세배 가량 높게 나타났다. 건평, 제품생산량 및 원료사용량을 기준으로 한 주요 수질 항목 (SS, $BOD_5$, COD, TN and TP)에서 단위공정(본 연구에서 산정한 값)의 오염원 발생원단위 결과값이 통합공정(국립환 경과학원에서 산정한 값)의 오염원 발생원단위 결과 값과 유사하였지만 다른 인자를 기준으로 한 경우에는 커다란 차이를 보여주었다. 섬유염색 및 가공업체에서 도출된 오염원 발생원단위 인자는 낙동강 수질 오염총량제 도입과 함께 수질오염 부하량 처리비용을 산정 할 때 유용한 자료로 활용될 수 있으리라 기대된다. 이러한 오염원 발생부하량 도출과 함께 낙동강 수계에서의 효과적인 수질오염제어와 관리를 위해서는 각 산업별 폐수처리시설의 유출수로부터 다양한 형태의 수질오염항목을 특성화시킬 필요가 있다.

상향류식 혐기성 슬러지 블랭킷 반응조에 비교한 생물전기화학 반응조의 산성 주정폐수처리성능 (Performance of Upflow Anaerobic Bioelectrochemical Reactor Compared to the Sludge Blanket Reactor for Acidic Distillery Wastewater Treatment)

  • 풍경;송영채;유규선;반와리 랄;난다쿠마르 쿱파난;산죽타 수부디
    • 대한환경공학회지
    • /
    • 제38권6호
    • /
    • pp.279-290
    • /
    • 2016
  • 중화하지 않은 주정폐수를 처리할 때 상향류식 혐기성반응조에 전극을 배치한 생물전기화학반응조의 성능을 UASB 공정과 비교하였다. UASB 공정은 유기물부하율 4.0 g COD/L.d 이하에서 pH, VFA 및 알카리도 등에 있어서 안정한 상태를 유지하였지만, 4.0 g COD/L.d 이상의 유기물부하율에서는 불안정하였다. 그러나, 생물전기화학 반응조는 UASB 반응조에 비하여 유기물부하율 배가시 상태변수들의 변동폭이 작았으며, 빠르게 정상상태로 회복하였다. 생물전기화학 반응조는 4.0-8.0g COD/L.d의 높은 유기물부하율에서 상태변수들이 UASB 반응조에 비하여 안정하였으며, 유기물부하율 8.0 g COD/L.d에서 비메탄발생율(2,076mL $CH_4/L.d$), 바이오가스의 메탄함량(66.8%) 그리고 COD 제거율(82.3%) 등의 측면에서 UASB 반응조보다 우수하였다. 생물전기화학 반응조의 메탄수율은 유기물부하율 4.0 g COD/L.d에서 약 407mL/g $COD_r$로 최대값을 보였으며, 이 값은 UASB의 282mL/g $COD_r$보다 크게 높았다. 중화하지 않은 산성 주정폐수를 처리하는 생물전기화학 반응조의 전극반응에서 율속단계는 산화전극반응이었으며, 전극반응은 높은 유기물부하율에서 pH에 의해서 크게 영향을 받았다. 생물전기화학 반응조는 유기물부하율 4.0 g COD/L.d에서 99.5%의 최대에너지효율을 보였다. 중화하지 않은 산성 주정폐수를 처리하는 생물전기화학 반응조는 UASB 공정보다 진보된 고율 혐기성 기술이 될 수 있다.

Hybrid-RBC와 BAF의 조합공정을 이용한 고농도 도축폐수의 처리 특성 (High Strength Slaughter Wastewater Treatment in a Novel Combined System of Hybrid-Rotating Biological Contactor and Biological Aerated Filter)

  • 정찬일;안조환;배우근;김승진
    • 대한환경공학회지
    • /
    • 제33권2호
    • /
    • pp.77-84
    • /
    • 2011
  • 본 연구에서는 부착/부유 미생물 혼재형 RBC (Rotating Biological Contactor)와 BAF (Biological Aerated Filter) 공정이 가지는 각각의 장점을 조합한 호기성 생물막 처리 시스템을 고안하여 고농도 도축폐수의 처리 특성을 평가하였다. 본 공정은 상당량의 부유 미생물이 함께 있는 RBC와 침전지 그리고 BAF 공정 순으로 구성되었다. 첫 번째 공정인 RBC와 침전지에서는 유기물의 산화, 질소의 질산화/탈질 및 부유물질의 제거가 이루어지며, 후속 공정인 BAF에서는 일부 제거되지 않은 유기물과 질소의 산화 및 부유물질의 여과가 이루어진다. 돈까스 소스(시판용)와 돼지피을 이용하여 모사한 고농도 도축폐수(TCOD $5.2{\sim}40.4g/m^2{\cdot}d$, TN $0.44{\sim}4.17g/m^2{\cdot}d$)의 처리 특성을 평가한 결과, 침전지를 포함한 RBC 공정에서 Soluble COD와 $NH_3-N$의 평균 제거율은 각각 90%와 82% 이상으로 양호하였으나 TCOD와 TN은 Suspended Solid (SS)의 대량 유출과 돼지피에서 기인한 콜로이드 물질 생성 때문에 각각 60%와 69%의 다소 낮은 제거율을 보였다. 후속 공정인 BAF가 잔존 TCOD와 TN을 제거하는 생물 반응조의 역할과 SS를 제거하는 여과기의 역할을 충분히 수행해 약 100 mg/L의 TCOD와 약 140 mg/L의 SS 추가 제거가 가능하였으나, 처리수질은 TCOD 300 mg/L, SS 180 mg/L 그리고 TN 53 mg/L로 상당히 높았다. RBC 유출수에 Polyaluminium Chloride를 투입한 결과, 침전성이 크게 향상되어 RBC+침전지 공정 유출수의 TCOD와 TN은 각각 93.8%, 25.6%의 제거율을 보였으며, BAF 유출수 수질은 TCOD 16.5 mg/L, SS 0 mg/L, NH3-N 12.0 mg/L, TP 1.3 mg/L로 우수하였다. 따라서 별도의 추가 처리공정 없이 본 연구에서 고안한 RBC+BAF 조합공정에 의한 처리만으로 고농도 도축폐수를 성공적으로 처리할 수 있었다.

생물학적 유동층을 이용한 어류양식 순환수의 처리씨스템 개발 (Developments of Water Treatment System by Biological Fluidized Bed for Water Reuse Aquaculture)

  • 이기완
    • 한국수산과학회지
    • /
    • 제26권4호
    • /
    • pp.380-391
    • /
    • 1993
  • 고밀도의 어류양식 순환수 처리씨스템 개발을 위하여 양식장의 수질특성 조사 및 생물학적 유동층 공정에 의한 모형 폐수처리 장치로 운영 실험한 결과를 요약하면 다음과 같다. 1) 단일어종을 양식하는 H 및 S 양만장 폐수의 경우 BOD $9.4{\sim}13.1\;mg/l$, COD(Mn) $14.5{\sim}20.0\;mg/l,\;NH_4-N\;1.1{\sim}2.3\;mg/l,\;NO_3-N\;15{\sim}21\;mg/l$이었고, 틸라피아 등 3종의 어류를 사육하는 B 및 K 양식장에서는 BOD $9.3{\sim}11.3\;mg/l$, COD(Mn) $8.0{\sim}11.1\;mg/l,\;NH_4-N\;7.3{\sim}20.2\;mg/l,\;NO_3-N\;26.9{\sim}46.4\;mg/l$의 수질특성을 나타내었다. 2) H 및 S 양만장 폐수의 BOD/COD 비율은 0.65로 거의 동질의 유기물 농도 값을 가지며, 틸라피아 등 3 종의 어류를 사육한 B 및 K 양식장 폐수에서는 크게 상이하였다. 3) 양식장의 여과조 및 동육조내 DO 농도를 기준으로 한 시간별 수질변동폭은 $1.5{\sim}2.0$ 배로 조사되었다. 4) 양만장 폐수의 탄소성 유기물 분해속도상수값은 $0.049\;d^{-1}$, 질산화반응 속도상수값은 $0.035\;d^{-1}$로서 미생물 분해작용에 의한 BOD 곡선식은 다음과 같이 나타낼 수 있었다. $y_T=14.1(1-10^{-0.222t)+30.9(1-10^{-0.035(t-8)})$ 5) BFB 처리 씨스템의 $0.014{\sim}0.075g\;NH_4-N/g\;BVS{\cdot}day$ 부하 조건 하에서 5 배의 암모니아성 질소 부하량 증가에도 질산화율은 $65{\sim}79\%$로 안정되게 나타났다. 6) BFB 처리 씨스템에 있어서 $0.014g\;NH_4-N/g\;BVS{\cdot}day$의 낮은 암모니아성 질소 부하조건에서는 공존 유기물 농도가 실산화 반응속도 저하 요인으로 작용하였다. 7) 부하율 변화 영향을 받지 않을 것으로 예측되었던 미생물 농도 $3.04{\sim}3.44\;g/l$의 무산소 BFB 탈질 씨스템에서 T-N 부하율 증가시 T-N 제거율 감소경향이 뚜렷하였던 바, 그 이유는 화기성조내에서 호기성 질산화 미생물의 증식이 억제되었기 때문으로 파악되었다. 8) 부하율 변화에 따른 처리율의 안정성과 반응조내에서 고농도의 미생물유지 잠재력을 확보하는 BFB 방법은 소요 부지면적이 작고 처리효율을 임의로 선택할 수 있는 실용성이 보장되므로 기존의 처리방법보다 설계 및 운영면에서 유리할 것으로 평가되었다.

  • PDF

가축분뇨처리공정의 자동제어 인자 신뢰성 평가 및 적정 외부탄소원 공급량 지표 확립 (Estimation of Reliability of Real-time Control Parameters for Animal Wastewater Treatment Process and Establishment of an Index for Supplemental Carbon Source Addition)

  • 박재인;라창식
    • Journal of Animal Science and Technology
    • /
    • 제50권4호
    • /
    • pp.561-572
    • /
    • 2008
  • 다양한 조건하에서 가축분뇨처리공정을 운전하면서 각 자동제어 인자의 반응을 분석하고 ORP, DO, pH(mV)-time profile를 이용한 자동제어 신뢰성을 평가하였다. 또한 무산소 조건에서의 잔존 유기물 및 미생물 자기산화에 의한 탈질율을 고려한 적정 외부탄소원 공급량 지표를 파악하였다. 실험은 45L의 유효용적을 지닌 실험실 규모의 SBR 공정을 이용하여 수행되었다. ORP-와 pH(mV)-, DO-time profile 상에서 완전질산화를 의미하는 NBP가 뚜렷하게 발현하던 중 NH4-N의 낮은 부하와 고농도 NOx-N 함유 폐수의 유입 및 불충분한 무산소 조건 제공이 이루어졌을 때 ORP-와 DO-time profile 상에서 NBP가 사라지기 시작하였으며 NOx-N의 지속적인 증가에 의해 ORP 값의 민감성이 둔화되기 시작하였다. 그러나 pH(mV)-time profile은 항상 일정한 변화패턴을 유지하면서 암모니아성 질소의 완전 질산화가 이루어졌을 때 뚜렷한 NBP를 발현하였다. NOx-N/NH4-N의 비가 80:1 수준까지 높아지는 조건하에서도 pH(mV)- time profile상에서의 이러한 안정적 NBP의 발현은 지속되었으며 발현되는 NBP는 MSC(Moving Slope Change)의 변화 패턴을 추적함에 의해 인식되도록 프로그램 할 수 있었다. pH(mV)-time profile에서의 NBP의 발현과 MSC를 이용한 자동제어시점 인식은 반응조내 NOx-N 농도가 무려 300mg/L 이상의 수준에서도 안정적이었다. 유기물 농도에 따른 자동제어 인자의 반응을 분석한 시험에서도 반응조내 유기물의 농도가 STOC 기준 약 10,000mg/L 수준으로 증가함에도 불구하고 pH(mV)-time profile 상에서의 이러한 NBP 발현은 지속되었으며 고농도 유기물 축적 하에서도 동일한 자동제어 알고리즘이 이용될 수 있음을 알 수 있었다. 잔존 유기물과 미생물 자기산화에 의한 탈질율은 약 0.4mg/L.hr로 분석되었으며 안전지수 0.1을 도입하여 산출된 NOx-N 기준 적정 외부탄소원 공급량은 0.83 STOC/NOx-N으로 파악되었다.