• Title/Summary/Keyword: High humidity

Search Result 1,711, Processing Time 0.027 seconds

A Correlation Analysis between Visibility and PM10 in Jinju (진주지역 시정과 미세먼지(PM10) 농도와의 상관관계)

  • Kim, Hyoung-Kab;Suh, Jeong-Min;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.535-542
    • /
    • 2017
  • This study was conducted to investigate how $PM_{10}$ concentration and Relative Humidity (RH) affected visibility in Jinju, Korea. A 9-yr dataset of 1 h averages for visibility, $PM_{10}$, and RH data was analyzed to examine the correlation between these variables. On average, visibility decreased by 1.4 km for every $10{\mu}g/m^3$ increase in $PM_{10}$ and by 2.1 km for every 10% increase in RH. In general, a negative correlation was observed between visibility and and $PM_{10}$ concentration. However, under conditions of low $PM_{10}$ concentration(< $15{\mu}g/m^3$) and visibility(< 2 km), there was a positive correlation between these two variables. In this case, RH levels were high (> 75%). A high correlation analysis between two variables need to be under control conditions with RH < 75%, $PM_{10}$ $15{\sim}100{\mu}g/m^3$, and visibility > 2 km.

Meteorological Factors Affecting Winter Particulate Air Pollution in Ulaanbaatar from 2008 to 2016

  • Wang, Minrui;Kai, Kenji;Sugimoto, Nobuo;Enkhmaa, Sarangerel
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.244-254
    • /
    • 2018
  • Ulaanbaatar, the capital of Mongolia, is subject to high levels of atmospheric pollution during winter, which severely threatens the health of the population. By analyzing surface meteorological data, ground-based LIDAR data, and radiosonde data collected from 2008 to 2016, we studied seasonal variations in particulate matter (PM) concentration, visibility, relative humidity, temperature inversion layer thickness, and temperature inversion intensity. PM concentrations started to exceed the 24-h average standard ($50{\mu}g/m^3$) in mid-October and peaked from December to January. Visibility showed a significant negative correlation with PM concentration. Relative humidity was within the range of 60-80% when there were high PM concentrations. Both temperature inversion layer thickness and intensity reached maxima in January and showed similar seasonal variations with respect to PM concentration. The monthly average temperature inversion intensity showed a strong positive correlation with the monthly average $PM_{2.5}$ concentration. Furthermore, the temperature inversion layer thickness exceeded 500 m in midwinter and overlaid the weak mixed layer during daytime. Radiative cooling enhanced by the basin-like terrain led to a stable urban atmosphere, which strengthened particulate air pollution.

A Study on Nocturnal Inversion at Urban Area in Winter (동절기 도심지 야간 기온역전에 관한 연구)

  • Zheng, Hai-Yan;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • In urban area, inversion layer prevents air pollutants from being dispersed. To determine nocturnal inversion characteristics at SookMyung Girls' High School near high-rise residential commercial complex buildings in Seoul, air temperature and humidity data were observed at 10minute interval from December 1st, 2007 to May 2nd, 2008. Temperature-Humidity (T-H) sensors were installed at SMG (SookMyung_Ground) and SMR (SookMyung_Roof), and then these two data were compared, analyzed and examined to illustrate air temperature differences of SMG and SMR. After the analysis, the maximum nocturnal inversion was observed by $3.3^{\circ}C$ at 18:10 on December 26th 2007, at that time the weather condition was clear and weak wind. Nocturnal inversions began 2-3 hours before sunset and it reached maximum inversion just after sunset and continued through nighttime until sunrise or 1-2 hours after sunrise. In terms of seasonal variation nocturnal inversions occurred dominantly in March and April rather than winter season.

An Investigation and Analysis into the Architectural Conditions and Indoor Air Quality of Senior Citizens Public Welfare Institution in Incheon (인천지역 공공 노인복지시설의 건축조건과 실내공기질에 대한 실태조사 및 분석)

  • Kang, Seung A;Shin, Sung Shik;Kim, Yong Shik
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.59-64
    • /
    • 2009
  • The senior citizens population and welfare institution for them is increased. The senior citizens in welfare institution spend a long time in indoor and their health is greatly affected by the indoor environment. Therefore, the indoor environment of senior citizens welfare institution is very important. This study presents some primary data based on the survey of architectural conditions and the measurements of indoor air quality for senior citizens welfare institution. According to characteristic of region, six of Incheon Area's senior citizens public welfare institution are selected. An investigation and analysis into architectural conditions and indoor air quality including temperature, humidity, CO, $CO_2$, PM10, HCHO, TVOC are conducted. The temperature, humidity and $CO_2$ concentration is some high. The HCHO concentration is very high. The indoor flooring and furniture materials highly impacts on the concentration of HCHO and TVOC.

Relationship between Contrast Ratio of Conductive Particle and Contact Resistance on COG Bonding using ACF (ACF를 이용한 COG 접합 공정에서 도전볼의 음영비와 접촉 저항과의 관계)

  • Jin, Songwan;Jeong, Young Hun;Choi, Eun Soo;Kim, Bosun;Yun, Won-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.831-838
    • /
    • 2014
  • Chip on glass (COG) bonding using anisotropic conductive film (ACF) is a key technology to assemble a driver IC onto a LCD glass panel. In this paper, an experimental investigation was conducted to investigate the correlation between contact resistance and characteristics of image taken by machine vision based inspection system. The results show that the contact resistance was strongly influenced by the contrast ratio of conductive particle rather than the number of conductive particles. Also, number of conductive particles whose contrast ratio is below 0.75 is crucial for determining the quality of the assembled samples. On the other hand, in the result of high temperature high humidity storage test, the contrast ratio of samples was increased. However, in the case of open-circuit samples after temperature humidity storage test, the number of conductive particles whose contrast ratio is above 0.75 was more than that of the closed-circuit samples.

A Study on the Effects of Heat Stress on Feedlot Environment and Productivity of Dairy Cattle (고온 환경이 젖소의 생산성 및 축사환경에 미치는 영향 연구)

  • Kim, Byul;Lim, Joung-Soo;Cho, Sung-Back;Hwang, Ok-Hwa;Yang, Seung-Hak
    • Journal of Animal Environmental Science
    • /
    • v.20 no.2
    • /
    • pp.63-68
    • /
    • 2014
  • Environmental heat stress by global warming has a severe effect on the productivity of livestock and, in particular, on that of dairy cattle. Heat stress during high temperature environment directly and indirectly affects milk yield, milk quality and physiological response. This study was conducted to investigate the effects of heat stress on productivity and physiological responses of livestock. Temperature-humidity data logger were established inside the feedlot for measuring real time changes in the feedlot environment. Milk was collected every day for analysing the productivity of dairy cattle. Blood sample and respiration of dairy cattle were collected once in a week for investigating the physiological response factors. Blood component concentration associated with lipolysis metabolism and milk production showed change during tropical night period. Temperature humidity index (THI) of a specific location inside the feedlot showed continuously high levels.

A Study on Reliability Assessment of Ag-free Solder (무은 솔더의 신뢰성 평가에 관한 연구)

  • Kim, Jong-Min;Kim, Gi-Young;Kim, Kang-Dong;Kim, Seon-Jin;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.109-116
    • /
    • 2013
  • The solder is any of various fusible alloys, usually tin and lead, used to join metallic parts that provide the contact between the chip package and the printed circuit board. Solder plays an important role of electrical signals to communicate between the two components. In this study, two kinds of Ag-free solder as sample is made to conduct the thermal shock test and the high humidity temperature test. Low resistance is measured to estimate crack size of solder, using daisy chain. The low speed shear test is also performed to analyze strength of solder. The appropriate degradation model is estimated using the result data. Depending on the composition of solder, lifetime estimation is conducted by adopted degradation model. The lifetime estimated two kinds of Ag-free solder is compared with expected lifetime of Sn-Ag-Cu solder. The result is that both Ag-free composition are more reliable than Sn-Ag-Cu solder.

A Performance Evaluation of Plate Type Enthalpy Exchanger through CFD Analysis of Elements (열 교환 소자 형상의 CFD 시뮬레이션을 통한 판형 전열 교환기 성능평가)

  • Kang, In-Sung;Ahn, Tae-Kyung;Park, Jin-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In order to better save energy, many buildings have been constructed with high levels of insulation and airtightness in recent years. Additionally, having high quality indoor air has become more relevant, necessitating a ventilating system. This study is aimed at evaluating the performance of a humidity exchanger through computational fluid dynamics (CFD) analysis of elements for the purpose of providing comfortable indoor air and reduced energy consumption. The simulation was conducted with three different shapes (triangle, rectangular, and curve) of heat exchanger elements, in order to find the most effective element. A follow-up simulation then proved the efficiency of the chosen humidity exchanger, which was selected by analyzing the results of the preceding simulation, comparing study data with measurement data from the Korea Testing Laboratory (KTL). The resulting analysis revealed that the rectangular element showed the lowest level of efficiency in both heating and cooling, while the curved element showed the highest level of efficiency in both heating and cooling.

A Study on the Characteristics of Total Heat Exchanger under Various Conditions (운전조건에 따른 전열교환기의 성능특성 연구)

  • Bail Cheol-Ho;Lim Young-Heon;Gulnora Diuraeva;Park Ji-Yeol;Kwak Kyung-Min;Chu Euy-Sung;Kim Young-Saeng;Kim Jee-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

Effects of Climatic Factors and Tapping Date on Yield and Quality of Lactree (Rhus verniciflua) Sap (기상요인과 채취시기가 옻나무 칠액채취량 및 칠액의 質에 미치는 영향)

  • 김만조
    • Korean Journal of Plant Resources
    • /
    • v.11 no.1
    • /
    • pp.70-79
    • /
    • 1998
  • This study was conducted to understand the effects of weather and tapping date on yield and quality of lactree(Rhus verniciflua) sap yield showed a significant positive correlation with the minimum temperature of one day before sap collection at 1% level and with theminimum humidity of theday of sap collection at 5% level. However, the differences between the maximum and the minimum temperatures and humidities of the day of sap collection were negatively correlated with the sap yield at 5% level. Multiple regression analysis indicated that the minimum temperature of one day bofore sap collection and the minumum humidity of the day sap collection were important factors for increasing sap yield. The high sap yield of lactree by Japanese tapping method was recorded during mid-July and early August. Seasonal variation in lactree sap constituents was observed. The sap collected on 15th of August contained the highest urushiol content (68.3%) and the lowest water content resulting in high quality of lactree sap. By reversed-phase HPLC analysis, fove urushiol components were separated from each other depending on the number of doulbe bonds in the side-chain , and seaxonal variation of urushiol composition was noticed. The 3-C15 triene content fo the sap collected on 5th of July was the highest(77.56%) indicating the major component of urushiol which affects lactree sap quality.

  • PDF