Discoloration of Lead Containing Pigments in Paintings(II) (회화에 사용되는 납 화합물 안료의 변색(II))

  • Hwang, In-sook
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.72-74
    • /
    • 2004
  • The color change of lead-containing pigments is one of the most serious diseases in watercolor, oil paintings and wall paintings. These pigments have a tendency to darken or brighten. It was proved that oxidation of lead containing pigments in the formation of brown-colored lead dioxide is a photochemical reaction under high humidity conditions. Therefore, we carried out some analogic experiments on the color change of three typical lead containing pigments ; $Pb_3O_4$, Pbo and $PbCo_3{\cdot}Pb(OH)_2$ at the conditions of illuminations under the high humidity ($2PbCo_3{\cdot}Pb(OH)_2$ R. H.). The reason for the chemical reactions are discussed and the results of these experiments are shown in some spectrograms, micrographs and X-ray micro-diffraction patterns. Important conclusions were drawn in our research. Due to the formation of brown $PbO_2$, red lead $(Pb_3O_4)$ and massicot (PbO) turned brown or dark when they were illuminated light under high humidity. We noticed that the brightening of red lead occurred d to admixture with chalk or lead white in egg yolk or linseed oil medium on exposure to light. Lead white used in oil paintings turned yellowish on dark.

  • PDF

The Relationships between Weather Factors and Photosystem II Activity in Three Cool-season Turfgrasses in Summer (한지형 잔디 3종의 하절기 광계II 활성과 기상요인과의 상관성)

  • Koh, Seok Chan
    • Journal of Environmental Science International
    • /
    • v.31 no.4
    • /
    • pp.311-318
    • /
    • 2022
  • In this study, we analyzed the relationships between weather factors and photosystem II activity (Fv/Fm), as a measure of photochemical efficiency, in three cool-season turfgrasses commonly planted on golf courses in Jeju, South Korea: perennial ryegrass (Lolium perenne L.), Kentucky bluegrass (Poa pratensis L.), and creeping bentgrass (Agrostis palustris Huds.). In all three turfgrasses, Fv/Fm was higher during late summer than during early summer. However, in late summer, Fv/Fm was significantly lower in perennial ryegrass than in the other two species. In early summer, Fv/Fm in perennial ryegrass and Kentucky bluegrass was positively correlated with mean low temperature and extreme minimum temperature, whereas, in late summer, this parameter in Kentucky bluegrass and creeping bentgrass was positively correlated with relative humidity, and in creeping bentgrass was negatively correlated with mean high temperature, mean low temperature, and extreme maximum temperature. These results indicate that raising low temperatures is favorable for perennial ryegrass and Kentucky bluegrass in early summer, whereas, in late summer, the lowering of high temperatures proves to be beneficial for creeping bentgrass, and raising relative humidity is conducive to the growth of Kentucky bluegrass and creeping bentgrass. These findings will contribute to improving the selection and management of turfgrasses on golf courses and sports fields.

Effect of $M_{2}CO_{3}$(M=Li, Na) Addition on the Humidity Sensitivity of $V_{2}O_{5}$-doped $TiO_2$ ($V_{2}O_{5}$를 dopant로 한 $TiO_2$의 감습에 미치는 $M_{2}CO_{3}$(M=Li, Na)의 영향)

  • 강이국;송창열;신용덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.343-346
    • /
    • 1995
  • In this paper, the effect of alkaline oxides on the humidity sensitivity of $V_2O_{5}$(2mol%)-doped $TiO_2$(98mol%) was investigated as functions of $Li_{2}Co_{3}$, $Na_{2}Co_{3}$. III-1. Measurement of Density. When the mole% of $Li_2$O is varied 0,1,2,5mol%, the more the mole% of additives is increased, the more difference of bulk and apparent density is largely narrowed. The difference of two densities of sample containing 2mol% $Na_2O$ was large all the moat. The sample containing 1mol% $Na_2O$ was small most. III-2. Observation of porosity. The porosity and total intrusion volume according to various amounts of $Li_2O$ was reduced and those of sample containing 2mol% $Na_2O$ as 31.13%, 0.1155mL/g was the highest and 1mol% $Na_2O$ was lowed most and 5, 10mol% $Na_2O$ was more high compare with sample without alkaline oxides. III-3. Characteristic of humidity sensitivity. 1. Impedance of samples containing $Li_2O$ was high compare with sample without alkaline oxides, so we thought it showed Poor sensitivity because it have no impedance changing rapidly as function of relative humidity. 2. When the humidity was increasing from 30RH% to 90RH%, the impedance of sample containing 2mol% $Na_2O$ at 120HZ changed exponential rapidly from 6${\times}$$10^{7}$$\Omega$) to 1.25${\times}$$10^4$$\Omega$. At under 50RH% and over 50RH%, the humidity sensitivity of samples containing 2mol% $Na_2O$ was best especially in the range of the low humidity. III-4. Characteristic of TG curves. When algal me oxide $M_{2}CO_{3}$(M=Li, Na) were added into $V_{2}O_{5}$-doped $TiO_2$, the stability of humidity sensitivity of samples containing amounts of $Li_2O$ was unstable. The samples containing 1mol% $Na_2O$ was unstable.

  • PDF

Design of a Prototype System for Graft-Taking Enhancement of Grafted Seedlings Using Artificial Lighting - Effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system (인공광을 이용한 접목표 활착촉진 시스템의 시작품 설계 - 활착촉진 시스템 내의 기온과 상대습도 분포에 미치는 기류속도의 효과)

  • 김용현
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.213-220
    • /
    • 2000
  • Grafting of fruit-bearing vegetables has been widely used to increase the resistance to soil-borne diseases, to increase the tolerance to low temperature or to soil salinity, to increase the plant vigor, and to extend the duration of economic harvest time. After grafting, it is important to control the environment around grafted seedlings for the robust joining of a scion and rootstock. Usually the shading materials and plastic films are used to keep the high relative humidity and low light intensity in greenhouse or tunnel. It is quite difficult to optimally control the environment for healing and acclimation of grafted seedlings under natural light. So the farmers or growers rely on their experience for the production of grafted seedling with high quality. If artificial light is used as a lighting source for graft-taking of grafted seedlings, the light intensity and photoperiod can be easily controlled. The purpose of this study was to develop a prototype system for the graft-taking enhancement of grafted seedlings using artificial lighting and to investigate the effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system. A prototype graft-taking system was consisted by polyurethane panels, air-conditioning unit, system controller and lighting unit. Three band fluorescent lamps (FL20SEX-D/18, Kumho Electric, Inc.) were used as a lighting source. Anemometer (Climomaster 6521, KANOMAX), T-type thermocouples and humidity sensors (CHS-UPS, TDK) were used to measure the air current speed, air temperature and relative humidity in a graft-taking system. In this system, air flow acted as a driving force for the diffusion of heat and water vapor. Air current speed, air temperature and relative humidity controlled by a programmable logic controller (UP750, Yokogawa Electric Co) and an inverter (MOSCON-G3, SAMSUNG) had an even distribution. Distribution of air temperature and relative humidity in a graft-taking enhancement system was fairly affected by air current speed. Air current speed higher than 0.1m/s was required to obtain the even distribution of environmental factors in this system. At low air current speed of 0.1m/s, the evapotranspiration rate of grafted seedlings would be suppressed and thus graft-taking would be enhanced. This system could be used to investigate the effects of air temperature, relative humidity, air current speed and light intensity on the evaportranspiration rate of grafted seedlings.

  • PDF

Indoor Environment Control System Utilizing The Internet of Things (사물인터넷을 활용한 실내 환경 제어 시스템)

  • An, Yoon-Jung;Kim, Dong-Hyeok;Lee, Jee-Hyun;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.645-650
    • /
    • 2017
  • It is a system that controls temperature, humidity and fine-dust to make interior environment more comfortable for modern people who spend 90% of the time in indoor. In an experiment of finding which one of temperature and humidity influence more to discomfort index, for a fixed temperature of 21, discomfort index increased by 0.1 with a 1 change of humidity, and for a fixed humidity of 40, discomfort index increased by 1.2 with a 1 change of temperature. As a result, it was found that the temperature is more influential than the humidity to discomfort index. In an experiment of measuring communicational limitation of Bluetooth, the communication was possible for at most 30 meters without obstacles. With high obstacles like walls or steel bars, it was able to penetrate at most 2 obstacles and maximum distance which it can communicate was 10 meters for just one high molecule obstacle.

Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions (측정방법 및 기상상태에 따른 PM-10 질량농도 비교)

  • Jung, Chang Hoon;Park, Jin Hee;Hwang, S.M.;Jung, Y.G.
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

A Study on Production of Nitrogen Oxides in Plasma Reactors

  • Lim, Gye-Gyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E3
    • /
    • pp.91-99
    • /
    • 2001
  • Plasma reactor was used to generate a high potential difference between two surfaces of concentric pyrex tubes by electrical current. The annular gap of the reactor was calculated by trial and error from the breakdown voltage equation and set at 0.45 cm. The overall objective of this research was to know the effects of the frequency, humidity, and residence time on the formation of nitrogen oxides in a plasma reactor. The primary voltage varied from 50 to 90 volts and the frequency was varied in increments of 10 Hz from 60 to 650 Hz at the primary voltage of 90. The increase in the secondary voltage was not linear but exponential at high frequencies. At a maximum concentration of about 745 ppm, the frequency and secondary voltage was 600 Hz and 4,200 volts, respectively. All tests for the effects of humidity on NO$_{x}$ production were performed at the optimal setting of 90 colts and 600 Hz frequency. Since the NO$_{x}$ production was not an one dimensional phenomenon, competing reactions were assumed to occur in the discharge chamber. The sharp peak concentration of 1,810 ppm was observed at 38% of relative humidity, The enhanced production was choked off, and the production rate rapidly dropped to 3 ppm at above 40% of relative humidity. It is assumed that the corona attacks the most vulnerable molecules in the reaction chamber before attacking other more lightly bonded molecules, possibly at humidities above 38% and the optimized 90 volt setting. Thus, there was not enough energy left after attacking all water molecules to decompose an appreciable amount of $N_2$. If nitrogen breakdown does not occur, then oxides of nitrogen are not likely to be produced.ced.

  • PDF

Main Factors that Effect on the Ion-Migration of PCB (PCB의 이온-마이그레이션에 영향을 미치는 주요요인)

  • Jang, In-Hyeok;Kim, Jeong-Ho;Oh, Gil-Gu;Lee, Young-Joo;Lim, Hong-Woo;Choi, Youn-Ok
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.202-207
    • /
    • 2016
  • Purpose: The purpose of this study is main factors (environmental conditions, pattern spacing, pattern material) that effect the ion-migration of PCB. Methods: Recently, the electronic components are becoming more high density of electronic device, so that electronic circuits have smaller pitches between the patten and more vulnerable to insulation failure. so the reliability of electric insulation of device has become an ever important issue as device contact pitches of pattern. Usually, ion-migration occurs in high temperature and high humidity environment as voltage is applied to the circuit. Under high temperature and high humidity, voltage applied electronic components respond to applied voltages by metals's electrochemical ionization and a conducting filament forms between the anode and cathode across a nonmetallic medium. This leads to short-circuit failure of the electronic component. Results: we studied ion-migration that occurs in accordance with the main factors (environmental conditions, pitches, pattern material). The PCB pattern material was made by two different types of material (free solder, OSP) for this research and pitches of pattern is 0.15mm, 0.3mm, 0.5mm. PCB was experimented in the environmental conditions (high temperature $120^{\circ}C$, high temperature and high humidity $85^{\circ}C$, 85%RH) and was analyzed for ion-migration through the experiment results. Conclusion: We confirmed that environmental condition, pitches of pattern, pattern material had effect on ion-migration of PCB.

Purgative Effect of Jechun-Jun(Jichuan-Jian) and Add or Omit Herbs in Rat (제천전(濟川煎)과 약물(藥物) 가감(加減)이 흰쥐의 사하작용(瀉下作用)에 미치는 영향(影響))

  • Lee Seung-Hee;Lee Sang-Jun;Park Soo-Yeon;Kim Hong-Yeoul;Park Seong-Kyu
    • Herbal Formula Science
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2002
  • We have examined the purgative effect of three Jechun-jun formulas in sprague dawley(SD) rat. Three jechun-jun formulas were Jechun-jun(Sample I ) and augmented Jechun-jun(Sample II) and augmented Jechun-jun add rhubarb(sample III ). We examined the amount and the humidity of feces in rat. The experimental animals were devided into four groups. as control group and three Jechun-jun (sample I, II, III). We administerd the water extract of sample I, II, III to rat per oral for 8days long. After every 24hours measured the amount of wet feces from rats in metabolic cage. Humidity rate of feces from rat was at first measure wet feces for 24hours (W) and measure dried feces (W1) and then we consider W-W1 as humidity. High humidity rate means constipation changes into moistening stool. The amount of wet feces and humidity rate of feces in rats were increased in sample I, II, III. Sample I has highest humidity rate of feces. so showed strong moistening effect. Sample II has mild effect in treating constipation. sample III has most amount of wet feces. in conclusion Jechun-jun has an effect of moistening stool. and augmented Jechun-jun add rhubarb has strong purgative effect.

  • PDF

Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth (식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화)

  • Park, Jong-Hyun;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.