Strength Changes of Corrugated Fiberboard Boxes for Fruits Packaging by Relative Humidity Temperature (과실포장용 골판지 상자의 온습도에 따른 강도 변화)

  • Jo, Jung-Yeon;Min, Choon-Ki;Shin, Jun-Seop;Lee, Myung-Hoon;Sohn, Ki-Zoo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.7 no.2
    • /
    • pp.43-51
    • /
    • 2001
  • This study was carried out to analyze changes of the physical properties of corrugated fiberboard boxes for fruits packaging by various moisture and temperature changes. There were significant decrease in burst strength with increased relative humidity. And also compressive strength(ring crush test) of corrugated fiberboard and box were reduced with moisture content. The decreasing amounts of single wall(SW) corrugated fiberboard was bigger than that of double wall(DW). The physical properties reductions of corrugated fiberboard and box were mainly affected by relative humidity. Therefore, it is suggested that development of the water-resistant corrugated fiberboard and box be useful under the condition of low temperature and high relative humidity such as the cold chain system.

  • PDF

Humidity Aging Effect on Adhesive Strength of Composite Single-lap Joint

  • Kim, Myungjun;Kim, Yongha;Kim, Pyunghwa;Roh, Jin-Ho;Park, Jungsun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.56-62
    • /
    • 2017
  • Because adhesively bonded joints are used in many structural systems, it is important to predict accurate adhesive strengths. Composite aircraft with many joints are easily exposed to low temperatures and high relative humidity. This paper presents a humidity aging effect on the adhesive strength of a composite single-lap joint (SLJ). The adhesive strength of the SLJ is predicted using a finite element analysis with a cohesive zone model (CZM) technique. The humidity aging effect is evaluated based on the adhesive strength and CZM parameters. A lap joint test is carried out on the composite SLJ specimens, which are exposed for four months of 100% R.H. at $25^{\circ}C$. The predicted strengths are in good agreement with experimental data, and the actual crack propagation is satisfactorily simulated using the local CZM technique.

Change in Curl of Newsprint by Physical Treatments - Effects of roll diameter, storage time, winding methods, calendering and humidity on curl - (물리적 처리에 의한 신문용지의 컬 변화 -권취롤의 직경, 저장 기간, 권취 방법, 캘린더링 및 습도의 영향-)

  • Lim, Yeon-Ju;Paik, Ki-Hyon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.3
    • /
    • pp.60-66
    • /
    • 2004
  • The effects of roll diameter, winding time, winding methods and relative humidity on curl In newsprints(46$g/m^2$, 54 $g/m^2$, and 54 $g/m^2$ SNC) are examined. The larger MD curl appears at smaller roll diameter, with the extension of winding time, and at the treat ment of soft nip calendering. The MD curl shows the back side curl at winding methods with top side as outer side(TSO), and the top side curl with top side as inner side(TSI). While the CD curl in newsprints( 46 $g/m^2$, and 54 $g/m^2$ SNC) treated with calender is hardly influenced by the storage times, roll diameter, and winding methods. However the CD curl in newsprint(54 $g/m^2$) gradually increases to a two weeks, and then hold constant regardless of roll diameter and winding methods.. The CD curl shows always the top side curl regardless of winding methods. At high relative humidity, the CD curl largely reduces, but the MD curl is not nearly changed. Especially, the CD curl in news-prints(54 $g/m^2$ SNC) is little affected by the changes of relative humidity.

Moisture Sorption and Desorption Characteristics of Tobacco Types. (담배종류별 흡습 및 방습 특성)

  • 김용옥;정한주;공판임;장기철
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.26 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • This study was carried out to investigate moisture sorption and desorption characteristics followed by tobacco type. Experiments were performed at various temperature(5, 15, 25, 40 $^{\circ}C$) and relative humidity range (11~84 %) controlled by saturated salt solution. Regression equation was obtained to predict equilibrium moisture according to various relative humidity, temperature and tobacco types. The obtained regression equation showed high $R^2$(above 0.95) and predicted accurate equilibrium moisture. Equilibrium moisture contents declines in the following order when a relative humidity is 50 % or above: expanded stem, flue-cured, expanded tobacco, reconstituted tobacco, USA flue-cured, orient, burley. To maintain 13 % moisture of each tobacco type in the range of 5~40 $^{\circ}C$ it is recommendable to control relative humidity 49~56 % for expanded stem, 50~57 % for flue-cured, 54~61 % for USA flue-cured, 56~60 % for reconstituted tobacco, 57~62 % for expanded tobacco, 58~64 % for orient and 58~65 % for burley, respectively. It means that the relative humidity of each tobacco type should be differently controlled to maintain the same moisture under the same temperature. In the range of 5~25 $^{\circ}C$, the lower temperature showed the higher equilibrium moisture content.

A Survey on the Sanitary Condition of Kitchens in School Food-service Programs (일부 학교급식소 조리실의 위생관리에 관한 조사연구)

  • 김종규
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.87-93
    • /
    • 2003
  • A survey including an inspection was conducted to assess the sanitary condition of kitchens in the school food-service programs and to prepare background data for improving the safety of school meals. The survey was carried out over a two-month period (September-October, 2001). A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools in one region of Korea about food, sanitation, and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during preparation, cooking, and service. The inspection results showed their sanitary rendition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4~22.4$^{\circ}C$. and the range of relative humidity was 62.4~69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22..5 to 26.5 CFU/15 minutes. Although the results of inspection show that the levels of sanitary condition of kitchens in the schools were good, they are not satisfactory for safe food-servile because the temperature and humidity levels are high. This study indicates that the school kitchens should be monitored and strict inspection is necessary. The legal standards for school food-service should include standards for kitchen air temperature, relative humidity, and airborne microbes.

A study on the fabrication and properties of $TiO_2$ thin films by Sol-Gel Method (Sol-Gel 법에 의한 $TiO_2$ 박막의 제조 및 물성에 관한 연구)

  • You, D.H.;Kim, J.S.;Kang, D.H.;Kim, Y.H.;Lee, D.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.59-62
    • /
    • 1992
  • In this study, $TiO_2$ thin films are fabricated by Sol-Gel method and dielectric, electric and humidity sensing properties have been investigated. The structure of Sol can be changed by controlling for hydrolysis reaction condition. The uniformity of the surface on $TiO_2$ thin films is confirmed by SEM. The permittivity of $TiO_2$ thin films increases according to heat treatment temperature, whereas the conductivity of $TiO_2$ thin films decreases according to heat treatment temperature, As the results of measuring humidity sensing properties of $TiO_2$ thin films fabricated as humidity sensor, it is confirmed to have good humidity sensing properties in high humidity and low frequency.

  • PDF

The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory (계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정)

  • Derebew, Mulugeta;Kim, Min Seok;Park, Yon Kyu;Lee, Ho Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

Development of Ceramic Humidity Sensor for the Korean Next Generation Reactor

  • Lee, Na-Young;Hwang, Il-Soon;Song, Chang-Rock;Yoo, Han-Ill;Park, Sang-Duk;Yang, Jun-Seong
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.435-443
    • /
    • 1998
  • Leak-before-break(LBB) approach has been shown to be both cost effective and risk reductive when applied to high energy Piping in nuclear Power Plants. For the Korean Next Generation Reactor (KNGR) development, LBB application is considered for the Main Steam Line(MSL) piping inside containment. Unlike the primary system leakages, the MSL leak detection systems must be based on principles other than radioactivity measurements. Among humidity, heat and acoustic noise currently being considered as indicators of leakage, we explored humidity as an effective one and developed ceramic-based humidity sensor which can be qualified for LBB applications. The ceramic material, sintered and annealed MgCr$_2$O$_4$-TiO$_2$, is shown to increase its electrical conductivity drastically upon water vapor adsorption over the entire temperature range of interest. With this ceramic sensor specimen, we suggested installation-inside-the-piping method by which we can detect leakage more rapidly and sensitively. In this paper, we describe the progress in the development and characterization of ceramic humidity sensor for the LBB application to the MSL of KNGR.

  • PDF

Comfortableness Evaluation Method using EEGs of the Frontopolar and the Parietal Lobes (전두엽과 두정엽의 뇌파를 이용한 쾌적성 평가 방법)

  • 김동준;김흥환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.374-379
    • /
    • 2004
  • This paper proposes an algorithm for human sensibility evaluation using 4-channel EEG signals of the prefrontal and the parietal lobes. The algorithm uses an artificial neural network and the multiple templates. The linear prediction coefficients are used as the feature parameters of human sensibility. Comfortableness for chairs and temperature/humidity are evaluated. Many conventional researches have emphasized that a wave of left prefrontal lobe is activated in case of positive sensibility and that of right prefrontal lobe is activated in case of negative sensibility. So the power ratio of a wave is obtained from FFT computation and the results are compared. The results of the comfortableness evaluation for temperature and humidity showed that the outputs of the proposed algorithm coincided with corresponding sensibilities depending on the task of the temperature and the humidity. The . conventional method using a wave is hardly related with comfortableness. And it is also observed that the uncomfortable state due to the high temperature and humidity can be easily changed to the comfortable state by small drop of the temperature and the humidity. It seems to be good results to get 66.7% of evaluation performance in spite of using EEG and the subject independent approach.

A Study on Removal Performance of $NH_3$ Odor Gas Using High Frequency Surface Discharge Body (고주파 연면방전체를 이용한 $NH_3$ 처리성능에 관한 연구)

  • 이주상
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 1996
  • The purpose of this study was to evaluate the decomposition efficiency of $NH_3$ odor gas using high frequency surface discharge body. The results from this study are as follows; 1, Voltage and frequency of electric elements have effects on removal of $NH_3$ odor. The higher these two elements were set up, the more efficiently deodorizing processing worked. In this experiment, the optimum voltage and frequency applicable were observed around AC 6.0 kVp-p and 24.0 kHz respectively. 2. The temperature, humidity and residence time were observed strong variables for NH$_3$ removal process. Its performance had limits at high temperature and humidity conditions. The longer the residence time continued, the more efficiently deodorization process worked. The experimental results showed that the deodorization was efficiently processed under such conditions as $30.0^{\circ}C$ in temperature, 60rh% in humidity and 0.3 sec in residence time. 3. It was observed that in deodorization experiment, $NH_3$ odor gas was perfectly decomposed under the concentration condition below 15.0ppm. Moreover it was considered as economic and practical in terms of maintenance cost when compared with other deodorization methods.

  • PDF