• 제목/요약/키워드: High frequency switching inverter

검색결과 418건 처리시간 0.025초

FB DC-DC Converter의 도전손실 저감과 무손실 스너버 회로에 관한 연구 (A Study on Reducing Conduction Losses and Lossless Snubber Circuit of Full-Bridge DC-DC Converter)

  • 라병훈;이현우;권순걸;김준홍;서기영;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2665-2667
    • /
    • 1999
  • This Paper proposes a new toplogy snubber circuit of Full-Bridge DC-DC Converter for reducing conduction losses and snubber circuit heating loss. Using Partial Resonent Soft Switching Method and Clamping, studying on a new snubber circuit for reducing losses that a snubber circuit heating loss in the secondly diode rectification side, a switching losses in the primary side of IGBT inverter and conduction losses in the high frequency insulation transformer. In this paper, we present FB DC-DC converter included a new lossless snubber circuit, and then be analyzed and simulated.

  • PDF

태양광 발전 시스템용 DC-DC 컨버터의 모델링 (Modeling of utility interactive photovoltaic system DC-DC converter)

  • 문상필;박영조;김영문;강욱중;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.215-217
    • /
    • 2002
  • In this paper, a new converter for utility interactive photovoltaic system is proposed, the conventional utility interactive photovoltaic system is composed of a PWM inverter and a DC converter. However, the increased switching loss and the high frequency switching noise become a problem. the control accuracy of the system is made to lower by the dead time of the switching devices. and it becomes a cause of the lower conversion efficiency. In order to resolve those problems, we applied a non- dissipative snubber circuit to a converter, which generates the single phase absolute value of sinusoidal current. the converter consists of two switching devices and one capacitor which constitute a non-dissipative snubber circuit. the proposed circuit is very useful to minimize and increase efficiency, when it is used to an utility interactive photovoltaic system. it is confirmed by simulation that the proposed converter for new photovoltaic system has stable operation and good output.

  • PDF

LCD 세정용 상압 플라즈마 전원장치 (Power Supply for LCO Cleaning Plasma)

  • 조형기;김규식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.282-284
    • /
    • 2006
  • UV lamp systems have been used for cleaning of display pannels of TFT LCD or Plasma Display Pannel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques be developed and improved. In this paper, 3kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, bi-directional high voltage pulse switching circuits are used to generate the high voltage plasma.

  • PDF

Single-Phase Inverter for Grid-Connected and Intentional Islanding Operations in Electric Utility Systems

  • Lidozzi, Alessandro;Lo Calzo, Giovanni;Solero, Luca;Crescimbini, Fabio
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.704-716
    • /
    • 2016
  • Small distributed generation units are usually connected to the main electric grid through single-phase voltage source inverters. Grid operating conditions such as voltage and frequency are not constant and can fluctuate within the range values established by international standards. Furthermore, the requirements in terms of power factor correction, total harmonic distortion, and reliability are getting tighter day by day. As a result, the implementation of reliable and efficient control algorithms, which are able to adjust their control parameters in response to changeable grid operating conditions, is essential. This paper investigates the configuration topology and control algorithm of a single-phase inverter with the purpose of achieving high performance in terms of efficiency as well as total harmonic distortion of the output current. Accordingly, a Second Order Generalized Integrator with a suitable Phase Locked Loop (SOGI-PLL) is the basis of the proposed current and voltage regulation. Some practical issues related to the control algorithm are addressed, and a solution for the control architecture is proposed, based on resonant controllers that are continuously tuned on the basis of the actual grid frequency. Further, intentional islanding operation is investigated and a possible procedure for switching from grid-tied to islanding operation and vice-versa is proposed.

무정전 전원(UPS)설계를 위한 PWN 인버터에 관한 연구 (A Study on the PWN Inverter for the Design of UPS)

  • 이성백;구용회;이종규
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제2권2호
    • /
    • pp.59-63
    • /
    • 1988
  • 고정 AC 전력전원에서 PWN(Pulse Width Modulation) 기법은 전압과 기본파 주파수를 가변 시키는 데 이용되어 왔다. 종래의 PWN 기법은 전류수, 필터크기 등의 문제점 때문에 PWN 출력 전압파형을 모터 구동 등의 제어 대상에 응용하는 연구가 진행되었다. 그러나 본 논문에서는 출력단 고속 스윗칭 소자를 사용하여 캐리어 주파수를 10(KHz)-45(KHz)까지 정현 PWN 시키고, 인버터의 출력단 파형은 소용량LPF(Low Pass Filter)를 사용하여 PAM(Pulse Amplitude Modulation)을 얻어냈다. 정현 PWN 제어 회로는 속응성과 제어성을 고려하여 마이크로 프로세서와 아날로그 회로로 혼합구성 하였다. 그리고 실험 결과는 변조도 0.6-1.0까지 변할 때 전압 파형을 관찰했다.

  • PDF

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

고속 3상 유도전동기 구동을 위한 새로운 RPWM 기법 (Novel RPWM Techniques for High-Speed Three-Phase Induction Motor Drive)

  • 권수범;이효상;박종진;김남준
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.364-371
    • /
    • 2004
  • 본 논문에서는 PWM 펄스를 랜덤하게 위치시킬 수 있는 새로운 3상 공간 벡터 RPWM(Random PWM) 기법을 제안한다. 기존의 RPWM 방식과 달리 3상 대칭 변조 기법에 의해 발생된 공간 전압 벡터 PWM(Space Vector PWM) 펄스를 랜덤하게 위치시키는 원리를 각 섹터마다 달리 적용하여 RPWM을 구현하는 기법을 제안한다. 제안 된 기법의 타당성 검증을 위하여, 제안된 RPWM 기법 알고리즘에 대해 MATLAB/SIMULINK를 이용한 시뮬레이션 및 DSP를 이용한 IGBT 인버터를 구성하여 실험을 수행한다. 특히 10,000 rpm 이상의 고속운전 시, 공간 전압 벡터 PWM 기법과 제안된 RPWM 기법에 의해 발생되는 인버터 출력 전류의 고조파 스펙트럼을 비교한다. 즉 전류 고조파 스펙트럼에서 스위칭 주파수 정수배에 해당하는 고조파의 크기를 비교하여 제안된 RPWM의 기법의 타당성을 검증하고자한다.

영구자석 브러시리스 AC 모터의 와전류 손실 특성해석 (Eddy Current Loss Analysis of the Permanent Magnet Brushless AC Motor)

  • 장석명;조한욱;이성호;정연호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.700-702
    • /
    • 2002
  • High-speed brushless permanent magnet machines are good for compressor and aerospace applications, etc. since they are conductive to high efficiency, high power density, small size and low weight. This paper presents 3-phase permanent magnet brushless AC Motor designed for the high-speed drives. Especially, we predicted the inverter high frequency pulse width modulation (PWM) switching caused eddy current losses in a permanent magnet brushless dc motor.

  • PDF

Employing Multi-Phase DG Sources as Active Power Filters, Using Fuzzy Logic Controller

  • Ghadimi, Ali Asghar;Ebadi, Mazdak
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1329-1337
    • /
    • 2015
  • By placing distributed generation power sources beside a big nonlinear load, these sources can be used as a power quality enhancer, while injecting some active power to the network. In this paper, a new scheme to use the distributed generation power source in both operation modes is presented. In this scheme, a fuzzy controller is added to adjust the optimal set point of inverter between compensating mode and maximum active power injection mode, which works based on the harmonic content of the nonlinear load. As the high order current harmonics can be easily rejected using passive filters, the DG is used to compensate the low order harmonics of the load current. Multilevel transformerless cascade inverters are preferred in such utilization, as they have more flexibility in current/voltage waveform. The proposed scheme is simulated in MATLAB/SIMULINK to evaluate the circuit performance. Then, a 1kw single phase prototype of the circuit is used for experimental evaluation of the paper. Both simulative and experimental results prove that such a circuit can inject a well-controlled current with desired harmonics and THD, while having a smaller switching frequency and better efficiency, related to previous 3-phase inverter schemes in the literature.

디지털 제어 교류 전동기 구동시스템의 전류 측정 오차 해석 및 보상 (Analysis and Compensation of Current Measurement Error in Digitally Controlled AC Drives)

  • 송승호;최종우;설승기
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.462-473
    • /
    • 1999
  • 디지털 제어 방식으로 구동되는 모든 교류 전동기 벡터제어시스템의 근간을 이루는 전류 측정에 관한 문제를 다룬다. 일반적인 펄스폭 변조 방식 교류 전동기 구동 시스템에서 전동기 전류에 포함된 인버터 스위칭 노이즈를 없애기 위하여 저역 통과 필터를 사용하는데 이러한 필터는 필연적으로 측정된 신호의 시간 지연을 유발하게 된다. 따라서 샘플링한 전류값에는 기본파 성분 뿐만아니라 고조파 리플 성분이 포함된다. 본 논문에서는 3상 대칭 펄스폭 변조시 기준 전압 벡터의 위치에 다른 전류 샘플링 오차를 해석적으로 구하고 이러한 샘플링 오차를 최소화하기 위한 기법을 제안한다. 제안된 지연 보상 샘플링 기법을 사용하면 정상 상태 전류 측정 오차를 최소화할 수 있고 보다 정확한 토오크 제어가 가능하게 됨을 시뮬레이션과 실험을 통해 보였다.

  • PDF