• 제목/요약/키워드: High frequency switching inverter

검색결과 418건 처리시간 0.03초

출력주파수체배 공진형 고주파 인버어터 (High frequency resonant inverter using time sharing control method for multipling output frequency)

  • 배영호;홍성태;이현우;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1129-1132
    • /
    • 1992
  • This paper proposes a high frequency resonant inverter consisting of equivalent half bridge model using MOSFET. In this paper time-sharing control method is applied. as a result the output frequency is two times as high as switching frequency of device, and average current of device is incresed because of decreasing switching loss.

  • PDF

3상 유도전동기 구동을 위한 새로운 2상 RPWM기법 (Novel Two-Phase RPWM Technique for Three-Phase Induction Motor Drive)

  • 이효상;김남준
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.430-437
    • /
    • 2004
  • 본 논문에서는 고주파 스위칭 시 스위칭 손실의 감소, 구현의 용이성 및 인버터 제어를 위하여 요구되는 연산시간 감소 등 다양한 장점을 가진 4-Switch 인버터를 대상으로, 새로운 2상 스위칭 패턴(Pattern)과 이에 적용된 새로운 SRP-PWM(Separately Random Pulse Position PWM)기법을 제안한다. 본 논문에서는 고속운전 영역에서의 인버터 출력전류의 고조파 스펙트럼을 넓은 주파수 영역으로 즉, 특정주파수의 side-band로 고루 분산시키는 결과로부터 제안한 스위칭 패턴과 이에 적용된 새로운 SRP-PWM기법의 고조파 저감효과를 확인하고자 한다. 따라서 DSP를 이용한 IGBT인버터에 의한 실험을 수행하고, 이로부터 얻은 결과를 MATLAB/SIMULINK를 이용한 시뮬레이션 결과와 비교ㆍ분석하여 제안된 기법의 타당성을 검증하고자 한다.

Lossless Inductor Snubber-Assisted ZCS-PFM High Frequency Series Resonant Inverter for Eddy Current-Heated Roller

  • Feng Y. L.;Ishitobi M.;Okuno A.;Nakaoka M.;Lee H. W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.304-308
    • /
    • 2001
  • This paper presents a novel prototype of ZCS-PFM high frequency series resonant inverter using IGBT power module for electromagnetic induction eddy current-heated roller in copy and printing machines. The operating principle and unique features of this voltage source half bridge inverter with two additional soft commutation inductor snubber are presented including the transformer modeling of induction heated rolling drum. This soft switching inverter can achieve stable zero current soft commutation under a discontinuous and continuous resonant load current for a widely specified power regulation processing. The experimental results and computer-aided analysis of this inverter are discussed from a practical point of view.

  • PDF

3상 멀티레벨 인버터 출력노이즈 저감에 관한 연구 (A Study on the Output Noise Reduction of 3-Phase Multilevel Inverter)

  • 김수홍;진강환;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.101-103
    • /
    • 2007
  • Since they use the low switching frequency in multilevel inverter systems, they generate the high low frequency harmonic components. Generally, LC filter is used at the output terminal of inverter systems to solve this problem. But it causes a voltage drop at the output terminal by use of damping resistors, and causes the problem in which system efficiency decreases due to power loss of the damping resistor. In this paper, we proposed an output filter design method for NPC three-level inverter systems with low switching frequency. And we analyzed the efficiency of the proposed filter system, and the effectiveness of the proposed system is verified by simulation and experimental results.

  • PDF

고역률 초퍼-인버터 일체형 고주파 발생회로의 특성해석에 관한 연구 (A Study on Characteristic Analysis of High Frequency Generating Circuit Integrated Chopper-Inverter with High Power-Factor)

  • 원재선;박재욱;남승식;이봉섭;석줄기;김동희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권10호
    • /
    • pp.610-617
    • /
    • 2004
  • This paper presents a novel high frequency generating circuit integrated chopper-inverter using ZVS with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant inverter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications. fluorescent lamp and DC-DC converter etc.

IGBT PWM 인버터 구동 유도전동기의 절연성능 향상기술 연구 (A Study on the Insulation Performance Improvement of Induction Motors Fed by IGBT PWM Inverter)

  • 황돈하;박도영;김용주;이영훈;김동희;이인우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.335-339
    • /
    • 2001
  • The recent advancements in power electronic switching devices have enabled high frequency switching operation and have improved the performance of pulse-width modulated (PWM) inverters for driving induction motors. But, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter. In this paper, the test results for evaluation on the stator winding insulation of low-voltage induction motors for IGBT PWM inverter applications are presented. The insulation characteristics are analyzed with partial discharge and dissipation factor tests. Also, insulation breakdown tests by switching pulse voltage are performed. An effective insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

Finite Control Set Model Predictive Current Control for a Cascaded Multilevel Inverter

  • Razia Sultana, W.;Sahoo, Sarat Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1674-1683
    • /
    • 2016
  • In this paper, a Finite Control Set Model Predictive Control (FCS-MPC) for a five level cascaded multilevel inverter (CMLI) with reduced switch topology is proposed. Five switches are used here instead of conventionally used eight switches. The main contribution of this paper is to make the MPC controller work for the reduced switch topology using only 19 voltage vectors in place of conventional 61 voltage vectors for a five level CMLI. This simplifies the execution of the MPC algorithm, paving a way for the significant reduction in the computational time. The controller makes use of the excellent ability of MPC to multitask, by adding one more objective which is to reduce the average switching frequency in addition to controlling the load current. This is especially important, since switching losses and therefore switching frequency is significant for high-power applications. The trade-off of this MPC is that the current is not as smooth as the 61 vector scheme, but well within the limits of IEEE standards. The results shown prove that this MPC works well in steady state and dynamic conditions too.

인버터 스위칭전압 파형에 의한 전동기 권선 영향 해석 (Analysis of Motor Winding impact by inverter Switching Voltage Waveforms)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.94-101
    • /
    • 1999
  • 본 논문은 PWM인버터 장치의 스위칭 서지에 관한 문제를 분석한 것이다. 교류 전동기의 효율적인 속도제어를 위한 가변속 구동 장치의 적용이 증가함에 따라 전동기와 가변속 구동장치에 관련된 고장이 발생한다. 산업용 전동기 설비에 PWM 드라이브의 도입은 때때로 높은 과도전압 피크에 의한 상권선 사이 절연파괴를 낳을 수 있다. 높은 스위칭 주파수와 결합한 전동기 케이블 길이는 적?한 드라이브 동작을 위한 매우 민감한 문제가 된다. 케이블 길이와 높은 스위칭주파수의 결과는 전동기와 인버터에 영향을 미칠 수 있다. 전동기 권선 절연레벨이 낮을 때, 높은 피크전압과 빠른 전압상승시간에 의해 생겨난 고장 확률은 높다. 전압반사는 전동기 용량, 여러 가변속 구동장치와 상승시간에 대해 계산하였으며 이를 도식적으로 나타내었다. 인버터 구동 교류 전동기 시스템에서 전동기 단자 과전압과 전압상승률을 줄이기 위한 필터효과도 언급하였다. 연구결과 전동기 용량과 전동기 절연정격 레벨이 낮을수록 그리고 스위칭 시간과 케이블 길이가 짧을수록 절연파괴의 가능성이 높아짐을 알 수 있었다.

  • PDF

가용 동작 주파수 범위를 고려한 FB-SRC 기반 IH 쿡탑 시스템의 전력 제어 방안 (Power Control Method for FB-SRC IH Cooktop System Considering Limited Switching Frequency Range Condition)

  • 황윤성;이주승;강승현;권만재;장은수;이병국
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.256-264
    • /
    • 2022
  • The frequency power control method (FCM) which has a wide operating frequency range is adopted for induction heating (IH) cooktops. When FCM is applied to the full-bridge series resonant converter (FB-SRC) based IH system, high-frequency switching of the inverter is required compared to the half-bridge SRC (HB-SRC)-based IH system. Therefore, the switching loss of the inverter increases, and applying FCM under the condition that the inverter operating frequency range is limited is difficult. Therefore, this paper proposes a control strategy with the phase shift power control method considering that limited frequency conditions are presented. Loss analysis following the control method is performed through simulation and mathematical analysis. In addition, the validity of the proposed control strategy is verified by analyzing the heating performance following the control method through the test results of the 3,200[W] prototype.

Sinewave-PWM ZVS Inverter using High-Frequency Transformer for Utility AC Voltage Link

  • Chandhaket S.;Ogura K.;Konishi Y.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.511-515
    • /
    • 2003
  • This paper presents a novel prototype of the utility-interfaced sinusoidal pulse width modulated (SPWM) inverter using the high-frequency flyback transformer fur the small-scale solar photo-voltaic power conditioner (1kW - 4kW). The proposed SPWM power conditioner circuit with a high-frequency link has a function of electrical isolation, which is vital fur solar photovoltaic power conditioner systems with the viewpoint of safety and convenience. The discontinuous conduction mode (DCM) operation of the flyback transformer is also maintained to simplify the topology of the inverter circuit and control scheme. First, the operating principle of the proposed circuit is described far the understanding of the circuit parameters establishment. Then, the digitally constructed SPWM control scheme is presented. The proposed circuit is verified by the computer simulation and the prototype experiment.

  • PDF