Employing Multi-Phase DG Sources as Active Power Filters, Using Fuzzy Logic Controller

  • Ghadimi, Ali Asghar;Ebadi, Mazdak
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1329-1337
    • /
    • 2015
  • By placing distributed generation power sources beside a big nonlinear load, these sources can be used as a power quality enhancer, while injecting some active power to the network. In this paper, a new scheme to use the distributed generation power source in both operation modes is presented. In this scheme, a fuzzy controller is added to adjust the optimal set point of inverter between compensating mode and maximum active power injection mode, which works based on the harmonic content of the nonlinear load. As the high order current harmonics can be easily rejected using passive filters, the DG is used to compensate the low order harmonics of the load current. Multilevel transformerless cascade inverters are preferred in such utilization, as they have more flexibility in current/voltage waveform. The proposed scheme is simulated in MATLAB/SIMULINK to evaluate the circuit performance. Then, a 1kw single phase prototype of the circuit is used for experimental evaluation of the paper. Both simulative and experimental results prove that such a circuit can inject a well-controlled current with desired harmonics and THD, while having a smaller switching frequency and better efficiency, related to previous 3-phase inverter schemes in the literature.

A Rotating Flux Pump Employing a Magnetic Circuit and a Stabilized Coated Conductor HTS Stator

  • Jiang, Z.;Bumby, C.W.;Badcock, R.A.;Long, N.J.;Sung, H.J.;Park, M.
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.239-243
    • /
    • 2016
  • High temperature superconductor (HTS) magnet systems usually employ metal current leads which bridge between the cryogenic environment and room temperature. Such current leads are the dominant heat load for these magnet systems due to a combination of electrical resistance and heat conduction. HTS flux pumps enable large currents to be injected into a HTS magnet circuit without this heat load. We present results from an axial-type HTS mechanically rotating flux pump which employs a ferromagnetic circuit and a Cu-stabilized coated conductor (CC) HTS stator. We show the device can be described by a simple circuit model which was previously used to describe barrel-type flux pumps, where the model comprises an internal resistance due to dynamic resistance and a DC voltage source. Unlike previously reported devices, we show the internal resistance and DC voltage in the flux pump are not exactly proportional to frequency, and we ascribe this to the presence of eddy currents. We also show that this axial-type flux pump has superior current injection capability over barrel-type flux pumps which do not incorporate a magnetic circuit.

HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석 (Analysis of PCI Cable Effects in HEMP Conducted Disturbance)

  • 장태헌
    • 한국전자파학회논문지
    • /
    • 제24권8호
    • /
    • pp.772-780
    • /
    • 2013
  • 고고도 핵폭발로 생성되는 고출력 전자기 펄스(HEMP)에 의해 복사성 방해 환경과 케이블 커플링에 의한 전도성 방해 환경이 조성된다. IEC 61000-2-10은 HEMP의 전도성 방해 환경에 대하여 정의한다. IEC 61000-5-5에는 HEMP 전도성 방해에 대한 보호 장치의 특성이 규정되어 있다. IEC 61000-4-24는 보호 장치에 대한 특성 측정 방법을 다루고 있다. IEC 61000-4-24:1997은 소형 보호 소자에 대한 측정 방법을 기술하고 있으나, 최근 많이 사용되고 있는 보호 소자와 필터가 결합된 형태의 조합형 필터에 대한 측정 방법은 미비한 상태이다. HEMP 전도성 방해 신호는 50 MHz 이하의 주파수 스펙트럼을 포함하고 있으므로 측정 셋업을 구성하는데 있어서 케이블의 굵기, 길이, 접지평면으로부터의 높이 등의 측정 셋업 파라미터의 특성을 파악하는 것이 중요하다. 본 논문에서는 HEMP 전도성 방해 전류 파형의 주파수 스펙트럼을 고려하고, 측정셋업에서 존재하는 케이블 파라미터의 영향을 분석하여 최적의 PCI 측정 방법을 도출하고자 한다.

단상 영구자석 동기 전동기의 가상 dq축 기반 초기 회전자 자극 검출 (Initial Rotor Polarity Detection of Single-phase Permanent Magnet Synchronous Motor Based on Virtual dq-axis)

  • 서승우;황선환;이기창
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.1004-1010
    • /
    • 2020
  • 본 논문은 단상 영구자석 동기전동기의 초기 회전자 자극 검출 기법을 제안한다. 대상 전동기는 저속 및 정지 상태에서 역기전력을 기반으로 위치 정보를 얻을 수 없다. 따라서 초기 개루프 기동이 필요하며 이 과정에서 저 전류 및 소프트 기동을 위한 초기 회전자 위치 정보가 필요하다. 제안하는 초기 회전자 자극 검출 알고리즘의 경우 비대칭 공극의 영향 및 영구자석 자속의 영향을 고려하였으며, 고주파 전압 신호 주입을 기반으로 정확한 검출을 위한 오프셋 전압을 이용하였다. 이때 고주파 전압 신호로부터 유도된 고주파 전류의 경우 가상의 dq축을 이용하여 유도된 전류의 최댓값 취득을 통해 회전자 영구자석 자극을 판별한다. 본 논문에서는 센서리스 운전의 저전류 및 소프트 기동을 위해 제안된 초기 회전자 자극 검출 알고리즘을 홀센서 신호를 근거로 효용성 및 타당성을 다수의 실험을 통해 검증하였다.

Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구 (A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor)

  • 신완호;송영훈;김한석;최연석;김석준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

영구자석 동기전동기의 초기위치를 추정하는 새로운 방법 (A new method for estimating the initial position of a PM synchronous motor with an incremental encoder)

  • 정두희;정동욱;하인중
    • 전자공학회논문지B
    • /
    • 제33B권7호
    • /
    • pp.183-188
    • /
    • 1996
  • In this paper, we propose a new method which estimates the initial position of a PM synchronous motor (PMSM) using an incremental ecoder. in cremental encoders are widely used in detecting rotor position since they are inexpensive. At starting procedure, however, the incremental encoders cannot give the information of the absolute rotor position. Hence, additional absolue encoder, which has $60^{\circ}C$ resolutio electrically, and signal lines called U, V, W, have been used in practical systems for starting injection of a high frequency test current. It does not require any additional information such as U, V, W signals for starting procedure and allows for cheap and simple implementation. Experimental results show that the proposed method can estimate the initial rotor positon with higher accuracy than the conventional method using U, V, W signals.

  • PDF

단일 전류센서를 가진 IPMSM 드라이브의 고주파 신호 주입 센서리스 제어 (A High Frequency Signal Injection Sensorless Control of an IPMSM Drive with Single Current Sensor)

  • 임준혁;김상일;김래영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.205-206
    • /
    • 2015
  • 본 논문에서는 단일 전류 센서를 가진 IPMSM 구동 시스템의 고주파 신호 주입 센서리스 제어를 제안한다. 단일 전류 센서 시스템에서 3상 전류를 재구축하기 위해 DC link 전류를 검출한다. DC link 전류를 이용하여 3상 전류를 재구축하는 경우의 문제점은 1개 또는 2개의 유효벡터가 DC link 전류를 검출하는데 필요한 최소 시간보다 짧게 인가될 때 발생한다. 센서리스 제어시 이러한 경우가 발생하면, 재구축된 전류의 왜곡에 의해 제어 성능이 저하된다. 본 논문은 전압 벡터가 작은 경우, 전류 예측을 통하여 신뢰할 만한 3상 전류를 재구축하여 전류의 왜곡을 줄임으로써 센서리스 제어 성능을 향상시켰다. 시뮬레이션을 통하여 제안한 기법의 타당성을 검증하였다.

  • PDF

Picosecond Mid-Infrared 3.8 ㎛ MgO:PPLN Optical Parametric Oscillator Laser with High Peak Power

  • Chen, Bing-Yan;Wang, Yu-Heng;Yu, Yong-Ji;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.186-190
    • /
    • 2021
  • In this study, a compact, picosecond, mid-infrared 3.8 ㎛ MgO:PPLN optical parametric oscillator (OPO) laser output with high peak power is realized using a master oscillator power amplifier (MOPA) 1 ㎛ solid-state laser seeded by a picosecond fiber laser as the pump source. The pump source was a 50 MHz and 10 ps fiber seed source. After AOM pulse selection and two-stage solid-state amplification, a 1,064 nm laser output with a repetition frequency of 1-2 MHz, pulse width of 9.5 ps, and a maximum average power of 20 W was achieved. Furthermore, a compact short cavity with a unsynchronized pump is adopted through the design of an OPO cavity structure. When the injection pump power was 15 W and the repetition frequency was 1 MHz, the average output power of idler light was 1.19 W, and the corresponding peak power was 119 kW. The optical conversion efficiency was 7.93%. When the repetition frequency was increased to 2 MHz, the average output power of idler light was 1.63 W, the corresponding peak power was 81.5 kW, and the optical conversion efficiency was 10.87%. At the same time, the output wavelength was measured at 3,806 nm, and the beam quality was MX2 = 3.21 and MY2 = 3.34.

Detection of Magnetic Nanoparticles in Tissue Using Magneto-Motive DP-OCT

  • Oh, Jung-Hwan;Lee, Ho;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • 제11권1호
    • /
    • pp.26-33
    • /
    • 2007
  • We demonstrate the capability of differential-phase optical coherence tomography (DP-OCT) to detect superparamagnetic iron oxide (SPIO) nanoparticles taken up by liver parenchymeal macrophages (Kupffer cells). We apply an external time-varying high-intensity focused magnetic field. Our experiments demonstrate a novel diagnostic modality to detect macrophages that have taken up SPIO nanoparticles. Magnetic force acting on the nanoparticles was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially increased and focused the magnetic field strength ($B_{max}$ = 2 Tesla). $ApoE^{-/-}$ mice were sacrificed 2 days post intravenous injections of different SPIO doses (1.0, and 0.1 mmol Fe/kg body weight). Livers of $ApoE^{-/-}$ mice with and without injection of SPIO nanoparticles were investigated using DP-OCT, which detects tissue movement with nanometer resolution. Frequency response of iron-laden liver movement was twice the stimulus frequency. Movement was not observed in livers of control mice. Results of our experiments indicate DP-OCT is a candidate methodology to detect tissue based macrophages containing SPIO nanoparticles excited by an external focused magnetic field.

회전자 위치 추정 PI 제어기를 이용한 비돌극형 PMSM 센서리스 제어 (Sensorless Control of Non-salient PMSM using Rotor Position Tracking PI Controller)

  • 이종건;석줄기;이동춘;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.664-670
    • /
    • 2004
  • This paper presents a new velocity estimation strategy of a non-salient permanent magnet synchronous motor (PMSM) drive without high frequency signal injection or special PWM pattern. This approach is based on the d-axis current regulator output voltage of the drive system that has the information of rotor position error. The rotor velocity can be estimated through a rotor position tracking PI controller that controls the position error to zero. For zero and low speed operation, PI controller gains of rotor position tracking controller have a variable structure according to the estimated rotor velocity. In order to boost the bandwidth of PI controller around zero speed, a loop recovery technique is applied to the control system. The proposed method only requires the flux linkage of permanent magnet and is insensitive to the parameter estimation error and variation. The designers can easily determine the possible operating range with a desired bandwidth and perform the vector control even at low speeds. The experimental results show the satisfactory operation of the proposed sensorless algorithm under rated load conditions.