DOI QR코드

DOI QR Code

Detection of Magnetic Nanoparticles in Tissue Using Magneto-Motive DP-OCT

  • Oh, Jung-Hwan (University of Texas M.D. Anderson Cancer Center) ;
  • Lee, Ho (School of Mechanical Engineering, Kyungpook National University) ;
  • Kim, Jee-Hyun (Computer Engineering Department, Kyungpook National University)
  • Received : 2006.10.23
  • Published : 2007.03.25

Abstract

We demonstrate the capability of differential-phase optical coherence tomography (DP-OCT) to detect superparamagnetic iron oxide (SPIO) nanoparticles taken up by liver parenchymeal macrophages (Kupffer cells). We apply an external time-varying high-intensity focused magnetic field. Our experiments demonstrate a novel diagnostic modality to detect macrophages that have taken up SPIO nanoparticles. Magnetic force acting on the nanoparticles was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially increased and focused the magnetic field strength ($B_{max}$ = 2 Tesla). $ApoE^{-/-}$ mice were sacrificed 2 days post intravenous injections of different SPIO doses (1.0, and 0.1 mmol Fe/kg body weight). Livers of $ApoE^{-/-}$ mice with and without injection of SPIO nanoparticles were investigated using DP-OCT, which detects tissue movement with nanometer resolution. Frequency response of iron-laden liver movement was twice the stimulus frequency. Movement was not observed in livers of control mice. Results of our experiments indicate DP-OCT is a candidate methodology to detect tissue based macrophages containing SPIO nanoparticles excited by an external focused magnetic field.

Keywords

References

  1. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and et al., 'Optical coherence tomography,' Science, vol. 254, pp. 1178-1181, 1991 https://doi.org/10.1126/science.1957169
  2. D. P. Dave and T. E. Milner, 'Optical low-coherence reflectometer for differential phase measurement,' Opt. Lett., vol. 25, pp. 227-229, 2000 https://doi.org/10.1364/OL.25.000227
  3. T. Akkin, D. P. Dave, T. E. Milner, and H. G. Rylander, 'Detection of neural activity using phase-sensitive optical low-coherence reflectometry,' Opt. Express., vol. 12, pp. 2377-2386, 2004 https://doi.org/10.1364/OPEX.12.002377
  4. J. I. Youn, T. Akkin, and T. E. Milner, 'Electrokinetic measurement of cartilage using differential phase optical coherence tomography,' Physiol. Meas., vol. 25, pp. 85-95, 2004 https://doi.org/10.1088/0967-3334/25/1/008
  5. S. A. Telenkov, D. P. Dave, S. Sethuraman, T. Akkin, and T. E. Milner, 'Differential phase optical coherence probe for depth-resolved detection of photothermal response in tissue,' Phys. Med. Biol., vol. 49, pp. 111- 119, 2004 https://doi.org/10.1088/0031-9155/49/1/008
  6. C. G. Rylander, D. P. Dave, T. Akkin, T. E. Milner, K. R. Diller, and A. J. Welch, 'Quantitative phasecontrast imaging of cells with phase-sensitive optical coherence microscopy,' Opt. Lett., vol. 29, pp. 1509- 1511, 2004 https://doi.org/10.1364/OL.29.001509
  7. R. Weissleder, D. D. Stark, B. L. Engelstad, B. R. Bacon, C. C. Compton, D. L. White, P. Jacobs, and J. Lewis, 'Superparamagnetic Iron-Oxide - Pharmacokinetics and Toxicity,' Am. J. Roentgenol., vol. 152, pp. 167-173, 1989 https://doi.org/10.2214/ajr.152.1.167
  8. P. R. Moreno, E. Falk, I. F. Palacios, J. B. Newell, V. Fuster, and J. T. Fallon, 'Macrophage Infiltration in Acute Coronary Syndromes - Implications for Plaque Rupture,' Circulation, vol. 90, pp. 775-778, 1994 https://doi.org/10.1161/01.CIR.90.2.775
  9. L. M. Coussens and Z. Werb,'Inflammation and cancer,' Nature, vol. 420, pp. 860-867, 2002 https://doi.org/10.1038/nature01322
  10. C. W. Jung and P. Jacobs, 'Physical and chemical properties of superparamagnetic iron oxide MR contrast agents: ferumoxides, ferumoxtran, ferumoxsil,' Magn. Reson. Imaging., vol. 13, pp. 661-674, 1995 https://doi.org/10.1016/0730-725X(95)00024-B
  11. R. M. Weisskoff and S. Kiihne, 'Mri Susceptometry - Image-Based Measurement of Absolute Susceptibility of Mr Contrast Agents and Human Blood,' Magnet. Reson. Med., vol. 24, pp. 375-383, 1992 https://doi.org/10.1002/mrm.1910240219
  12. Y. X. Wang, S. M. Hussain, and G. P. Krestin, 'Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging,' Eur. Radiol., vol. 11, pp. 2319-2331, 2001 https://doi.org/10.1007/s003300100908
  13. J. F. Schenck, 'Safety of strong, static magnetic fields,' J. Magn. Reson. Imaging., vol. 12, pp. 2-19, 2000 https://doi.org/10.1002/1522-2586(200007)12:1<2::AID-JMRI2>3.0.CO;2-V
  14. G. Marchal, P. Van Hecke, P. Demaerel, E. Decrop, C. Kennis, A. L. Baert, and E. van der Schueren, 'Detection of liver metastases with superparamagnetic iron oxide in 15 patients: results of MR imaging at 1.5 T,' AJR. Am. J. Roentgenol., vol. 152, pp. 771-775, 1989 https://doi.org/10.2214/ajr.152.4.771
  15. P. Reimer, N. Jahnke, M. Fiebich, W. Schima, F. Deckers, C. Marx, N. Holzknecht, and S. Saini, 'Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxideenhanced MR imaging, and spiral CT-ROC analysis,' Radiology, vol. 217, pp. 152-158, 2000 https://doi.org/10.1148/radiology.217.1.r00oc31152
  16. K. Tsushima, A. Nishie, K. Yoshimitsu, A. Taketomi, and H. Honda, 'Liver metastasis with apparent intratumoral superparamagnetic iron oxide uptake,' Eur. Radiol., vol. 15, pp. 2203-2204, 2005 https://doi.org/10.1007/s00330-005-2722-0
  17. R. L. Reddick, S. H. Zhang, and N. Maeda, 'Atherosclerosis in Mice Lacking Apo-E - Evaluation of Lesional Development and Progression,' Arterioscler. Thromb., vol. 14, pp. 839-839, 1994
  18. W. Hundt, R. Petsch, T. Helmberger, and M. Reiser, 'Effect of superparamagnetic iron oxide on bone marrow,' Eur. Radiol., vol. 10, pp. 1495-1500, 2000 https://doi.org/10.1007/s003300000350
  19. P. Cherukuri, J. Wosik, J. D. Hazle, S. Litovsky, M. Madjid, W. Casscells, J. T. Willerson, and M. Naghavi, 'Contrast-enhanced intravascular detection of vulnerable plaque using superparamagnetic iron oxide and a novel magnetic resonance imaging catheter.,' Am. J. Cardiol., vol. 90, pp. 23h-24h, 2002
  20. S. A. Schmitz, S. E. Coupland, R. Gust, S. Winterhalter, S. Wagner, M. Kresse, W. Semmler, and K. J. Wolf, 'Superparamagnetic iron oxide-enhanced MRI of atherosclerotic plaques in Watanabe hereditable hyperlipidemic rabbits,' Invest. Radiol., vol. 35, pp. 460-471, 2000 https://doi.org/10.1097/00004424-200008000-00002
  21. T. M. Said, S. Grunewald, U. Paasch, M. Rasch, A. Agarwal, and H. J. Glander, 'Effects of magneticactivated cell sorting on sperm motility and cryosurvival rates,' Fertil. Steril., vol. 83, pp. 1442-1446, 2005 https://doi.org/10.1016/j.fertnstert.2004.11.052
  22. T. Neuberger, B. Schopf, H. Hofmann, M. Hofmann, and B. von Rechenberg, 'Superparamagnetic nanoparticles for biomedical applications: Possibilities and limitations of a new drug delivery system,' J. Magn. Magn. Mater., vol. 293, pp. 483-496, 2005 https://doi.org/10.1016/j.jmmm.2005.01.064
  23. M. Chastellain, A. Petri, A. Gupta, K. V. Rao, and H. Hofmann, 'Superparamagnetic silica-iron oxide nanocomposites for application in hyperthermia,' Adv. Eng Mater., vol. 6, pp. 235-241, 2004 https://doi.org/10.1002/adem.200300574
  24. G. J. Tearney, H. Yabushita, S. L. Houser, H. T. Aretz, I. K. Jang, K. H. Schlendorf, C. R. Kauffman, M. Shishkov, E. F. Halpern, and B. E. Bouma, 'Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography,' Circulation, vol. 107, pp. 113-119, 2003 https://doi.org/10.1161/01.CIR.0000044384.41037.43
  25. A. L. Oldenburg, F. J. J. Toublan, K. S. Suslick, A. Wei, and S. A. Boppart, 'Magnetomotive contrast for in vivo optical coherence tomography,' Opt. Express., vol. 13, pp. 6597-6614, 2005 https://doi.org/10.1364/OPEX.13.006597

Cited by

  1. Pulse Analyzing System Using Optical Coherence Tomography for Oriental Medical Application vol.50, pp.5, 2011, https://doi.org/10.1143/JJAP.50.057001
  2. Specialty Fiber Coupler: Fabrications and Applications vol.14, pp.4, 2010, https://doi.org/10.3807/JOSK.2010.14.4.326
  3. Pulse Analyzing System Using Optical Coherence Tomography for Oriental Medical Application vol.50, pp.5R, 2011, https://doi.org/10.7567/JJAP.50.057001
  4. Frequency Swept Laser at 1300 nm Using a Wavelength Scanning Filter Based on a Rotating Slit Disk vol.13, pp.3, 2009, https://doi.org/10.3807/JOSK.2009.13.3.330
  5. Detection of Tendon Tears by Degree of Linear Polarization Imaging vol.13, pp.4, 2009, https://doi.org/10.3807/JOSK.2009.13.4.472