• Title/Summary/Keyword: High Tibial Osteotomy(HTO)

Search Result 10, Processing Time 0.031 seconds

A Newly Designed Miniplate Staple for High Tibial Osteotomy (근위골절술을 위한 Staple 설계)

  • Mun, Mu-Seong;Bae, Dae-Kyung
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

A Rehabilitation Protocol for High Tibial Osteotomy in Korean Medicine: A Report of 3 Cases (근위 경골 절골술 후 한방 재활치료 프로토콜을 적용한 재활치료의 임상적 효과: 증례 보고)

  • Geum, Ji-Hye;Ha, Won-Bae;Koh, Nak-Yong;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.3
    • /
    • pp.107-118
    • /
    • 2018
  • In this study, we propose a rehabilitation protocol involving Korean medicine for patients after high tibial osteotomy (HTO) and report its effectiveness. Three patients underwent HTO using the rehabilitation protocol involving Korean medicine. We estimated the outcome evaluating physical examination findings of the knee joint, numeric rating scale, pain disability index, Lysholm knee score, and walking state. After the treatment, we observed that knee movement and muscular strength were improved. In addition, the numeric rating scale, pain disability index, Lysholm knee score, and walking state of patients were improved. Therefore, a rehabilitation protocol involving Korean medicine can be effectively used for patients after HTO. The limitation of this study was the insufficient number of cases and the difficulty of follow-up because of the characteristics of this operation and the long periods of time that are needed for each phase of the protocol. Further studies are needed to design a rehabilitation protocol involving Korean medicine.

Effect of Anteromedial Cortex Oblique Angle on Change of Tibial Posterior Slope Angle in High Tibial Osteotomy Using Computer Assisted Surgery (CAS) (Computer Assisted Surgery(CAS)를 이용한 개방형 근위경골절골술 시 전내측피질골경사각이 경골후방경사각에 미치는 영향)

  • Lee, Ho-Sang;Kim, Jay-Jung;Wang, Joon-Ho;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.351-361
    • /
    • 2012
  • The leading surgical method for correcting the misalignment of the varus and valgus in the knee joint is the high tibial osteotomy (HTO). In the opening wedge HTO (OWHTO), there is no concern about damaging the peroneal nerve on the lateral tibia of the proximal fibula. OWHTO has been the preferred choice, as the opening of the correction angle can be modulated during the operation. The correction of the varus and valgus on the coronal plane are performed adroitly. Nevertheless, there have been numerous reports of unintended changes in the medial tibial plateau and posterior slope angle (PSA). The authors have developed an HTO method using computer-assisted surgery with the aim of addressing the abovementioned problems from an engineer's perspective. CT images of the high tibia were reconstructed three-dimensionally, and a virtual osteotomy was performed on a computer. In addition, this study recommends a surgical method that does not cause changes in the PSA after OWHTO. The results of the study are expected to suggest a clear relationship between the anteromedial cortex oblique angle of each patient and the PSA, and an optimal PSA selection method for individuals.

Development of Computer-Aided Surgery System for High Tibial Osteotomy Using Tracking-Pin and Fluoroscopic G-arm Images (Tracking-Pin과 Fluoroscopic G-arm 이미지를 이용한 경골근위부절골술 지원시스템 개발)

  • Koo, Bon-Yeol;Kim, Cheol-Woong;Lee, Sun-Hyuk;Bae, Ji-Hoon;Park, Cheol-Woo;Kim, Jay-Jung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.5
    • /
    • pp.331-343
    • /
    • 2011
  • High tibial osteotomy (HTO) is a widely accepted treatment for unicompartmental osteoarthritis of the knee and other lower extremity deformities, particularly for young and active patients. However, it is generally recognized as a technically demanding procedure. Thus the limitations of conventional surgical methods have been reported. Currently, the use of computer-aided surgery (CAS) system for successful surgery was increased. However it has been reported many problems such as expensive equipment, infection or fracture caused by inserting half-pin and delaying surgery. Therefore we propose a novel method which can be tracked by using tracking-pin inserted in arbitrary locations of the femur and tibia, and fluoroscopic images obtained from G-arm of antero-posterior and lateral-medial.

Short-Term Results of Hybrid Closed-Wedge High Tibial Osteotomy: A Case Series with a Minimum 3-Year Follow-up

  • Saito, Hidetomo;Saito, Kimio;Shimada, Yoichi;Yamamura, Toshiaki;Yamada, Shin;Sato, Takahiro;Nozaka, Koji;Kijima, Hiroaki;Miyakoshi, Naohisa
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.293-302
    • /
    • 2018
  • Purpose: High tibial valgus osteotomy (HTO) is a well-established surgical procedure for patients with medial compartment osteoarthritis (OA) of the knee. The hybrid closed-wedge HTO (CWHTO) procedure permits extensive correction in patients with severe deformities or patellofemoral joint OA. The aim of this study was to report the short-term results in a consecutive series of patients treated with hybrid CWHTO. Materials and Methods: We retrospectively evaluated the clinical outcomes and radiographic parameters in 29 consecutive knees that underwent hybrid CWTHO to correct medial compartment OA at an average follow-up of 52.6 months. Clinical outcomes were assessed using the Lysholm score and knee scoring system of the Japanese Orthopedic Association (JOA). The Kellgren-Lawrence grading system and pre- and postoperative mechanical axis (MA), femorotibial angle (FTA), posterior tibial slope, and patella height were assessed. Results: The FTA and MA significantly changed from $180.7^{\circ}$ to $170.4^{\circ}$ and from $22.0^{\circ}$ to $60.2^{\circ}$, respectively. No significant differences were observed between the mean pre- and postoperative posterior tibial slope, Insall-Salvati ratio, or Caton-Deschamps index. The postoperative JOA and Lysholm scores significantly improved from 76.7 to 95.8 and from 58.8 to 90.2, respectively. Conclusions: Satisfactory outcomes can be achieved with hybrid CWHTO in patients with medial OA.

Effect of Tibial Cut Planes and Hinge Axes on Medial Opening Wedge High Tibial Osteotomy (내측개방형 근위경골절골술의 경골절단면 및 경골개방축의 설정에 따른 영향)

  • Park, Byoung-Keon;Lee, Ho-Sang;Kim, Jay-Jung;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.835-846
    • /
    • 2011
  • In medial opening wedge high tibial osteotomy (OWHTO), researchers have reported critical problems caused by unexpected changes in the tibial posterior-slope angle. This unexpected change can be analyzed, but there is no general solution for cases with an oblique hinge axis and cut plane. We propose a general analysis model for OWHTO. We first evaluate the effects according to variation in the hinge axis and tibial cut plane and then define an ideal correction axis. This ideal axis, called the virtual tibial correction axis, is not on the tibial cut plane in general. In this paper, we also present an evaluation of feasibility of the proposed analysis model.

The comparative study of arthroscopic meniscectomy with or without high tibial osteotomy in patients with degenerative medial meniscus posterior horn tear (내반 변형을 지닌 내측 반월상 연골판 후방 골 기시부 퇴행성 파열 환자에서 반월상 연골판 절제술 단독과 근위 경골 절골술 동반 수술의 결과 비교)

  • Moon, Jae-Young;Seon, Jong-Keun;Song, Eun-Kyoo;Kim, Hyung-Soon;Yim, Ji-Hyeon;Cho, Hyun-Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.30-36
    • /
    • 2012
  • Purpose: We compared the clinical and radiological results of meniscectomy with HTO or without HTO for degenerative medial meniscus posterior horn with varus deformity. Materials and Methods: Forty-two patients who had medial meniscus degenerative root tear with varus deformity more than 3 degrees were included for this study. Among them, 30 patients were performed meniscectomy combined with open wedge HTO and 12 patients were performed only meniscectomy without HTO. The mean follow-up period was 52.5 months. The clinical results were evaluated based on symptom improvement, patients' subjective satisfaction for surgery and HSS score. We also compared the osteoarthritic progression between the group on preoperative and at the final follow up radiographs. Results: Symptom improvement was achieved in 83.3% (25 cases) with HTO group and 66.7% (8 cases) without HTO group at final follow up with a significant difference. Patients' satisfaction was achieved in 83.3% (25 cases) with HTO group and 58.3% (7 cases) without HTO group which has a significant difference. The HSS score was improved in both group (90.8: with HTO group, 89.0: without HTO group) at the final follow up without significant difference. WOMAC score was improved in both groups at the final follow up without significant difference. There were no significant differences in the osteoarthritic progression between two groups. Conclusion: The good clinical result for treatment of patient who have medial meniscus degenerative root tear with varus deformity, proximal high tibial osteotomy is considered absolutely necessary. However, the progression of degenerative arthritis, its effect on long term follow up will be needed.

  • PDF

Viscoelastic Behavior of High Density Polyethylene Using High Tibial Osteotomy with Respect to the Strain Rate (근위경골절골술(HTO)용 X-밴드 플레이트에 적용되는 고밀도 폴리에틸렌(HDPE)의 변형률속도에 따른 점탄성거동)

  • Hwang, Jung-Hoon;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.431-438
    • /
    • 2012
  • The mechanical behavior of the polymeric material, HDPE depends on both time and temperature. The study of the tensile behavior at different strain rates is important in engineering design of the orthopedics device such as X-band plate. The mechanical properties and deformation mechanisms of HDPE are strongly dependent on the applied strain rate. Generally, the deformation behavior of HDPE based on the stress-strain curve is complex because of the highly inhomogeneous nature of plastic deformation, particularly that of necking. Therefore, we attempted to determine the mechanical behavior of HDPE in this study. Normally, tensile testing under various strain rates of the HDPE has been used to determine the mechanical behavior. We performed tensile tests at various strain rates (1 to 500 %/min) to analyze the viscoelastic behavior on increasing the strain rate. A tensile stress-strain curve was plotted from the data, and the point of transition was marked to calculate the transition stress, strain, and modulus.