• Title/Summary/Keyword: High Temperature Measurement

검색결과 1,525건 처리시간 0.025초

순수 2 차원 절삭에서 적외선 열화상을 이용한 주변형 영역의 온도 분포 측정 (Measurement of Temperature Field in the Primary Deformation Zone in 2-D Orthogonal Machining Using IR (Infra-Red) Thermography)

  • 김명재;정현기;황지홍
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.853-862
    • /
    • 2012
  • The present study develops a method for directly measuring the temperature field in the primary deformation zone with a high spatial resolution during 2-D orthogonal machining. This is enabled by the use of a high-speed, charge-coupled device (CCD) based, infra-red (IR) imaging system which allows characteristics of the temperature field such as the location and magnitude of the highest temperature and temperature gradient in the primary deformation zone to be identified. Based on these data, the relation between the machining temperature and the cutting conditions is investigated.

고속철도차량 주변압기 기계적 특성 분석 (A Study on Mechanical Characteristic Analysis for Main Transformer of High Speed Railway)

  • 한영재;김석원;이태형;구훈모;조광우;박상옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.713-718
    • /
    • 2006
  • In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measuring system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measuring system, KRRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.

  • PDF

2단분할법 측정 실험계획에 의한 게이지 정밀도 산정 (Calculation of Gauge Precisions by Measurement Experimental Design for Split Split Plots)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.649-657
    • /
    • 2009
  • The paper presents the measurement split split-plot models for saving the time and cost. The split split-plot designs developed are efficiently used to estimating the gauge R&R(Reproducibility & Repeatability) when the completely randomized design of all factors(such as high pressure and temperature) is expensive and time consuming. The models studied include three split split-plots considering the type of experimental units.

  • PDF

전기 전도도를 이용한 $H_2$O/LiBr 용액의 실시간 농도의 측정 (On-line Measurement of $H_2$O/LiBr Concentration using Electric Conductivity)

  • 박찬우;김정환;강용태
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1078-1083
    • /
    • 2002
  • The objectives of this paper are to measure the concentration of $H_2$O/LiBr solution by measuring the electrical conductivity and to study the effect of the solution temperature and the concentration on the electrical conductivity of the solution. The solution temperature ranges $20^{\circ},\;40^{\circ},\;and\; 60^{\circ}$ for a fixed concentration during the experiment. The valid ranges of the concentration are two regions, low concentration region (1~20% of LiBr) and high concentration region (55~66% of LiBr). The results show that the conductivity of the solution increases linearly with increasing the solution temperature while it increases without creasing the concentration lower than about 35% of LiBr and decreases with increasing the concentration higher than 35%. This paper proposes experimental correlations for the concentration as functions of the solution temperature and the concentration with error band of $\pm7$% for the low concentration region and $\pm1$% for the high concentration region, respectively. The experimental correlation can be practically used in the on-line measurement without any sampling of solution from the closed system.

수직 온도구배를 갖는 공기 흡입 덕트의 기계적 격리기법 (Mechanical Isolation Method for an Air Intake Duct with Vertical Temperature Gradient)

  • 정치훈
    • 한국추진공학회지
    • /
    • 제20권4호
    • /
    • pp.87-93
    • /
    • 2016
  • 직접 연결식(DC) 고도모의 엔진시험 수행 시, 공기 흡입 덕트와 항공용 엔진 사이에 래버린스 씰이 설치된다. 래버린스 씰은 이 둘을 기계적으로 격리시킴으로써 주추력 및 측추력을 보다 정확하게 측정할 수 있도록 돕는다. 하지만 덕트 내부 공급공기에 높은 수직 온도구배가 발생할 경우, 래버린스 씰의 격리가 파괴되어버린다. 본 논문에서는 이러한 접촉 문제를 해결하기 위한 노력의 일환으로 래버린스 씰 온도 제어장치를 제작/설치하였다. 본 장치를 실제 항공용 엔진시험에 적용한 결과, 높은 수직 온도구배가 생성되어도 래버린스 씰의 격리가 잘 유지되는 것을 확인할 수 있었다.

고주파 부분방전 측정에 의한 초고압 접속함 신뢰성 평가 기술 (A Evaluation Technique for Reliability of Extra-High Voltage Cable Accessories using High Frequency Partial Discharge Measurement)

  • 신두성;이창영;김충식;전승익;김동욱;박완기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.186-195
    • /
    • 2000
  • In this paper, partial discharge (PD) measurement was performed to evaluate the quality of the cable joint and termination constructions. The resistive coupling technique for PD detection using resistivity of semiconducting layer of the cable in the accessories, such as joints and terminations. With high frequency PD (HEPD) measurement, an excellent sensitivity below 20pC could be achieved under unshielded condition. The localization of the defects in the accessories could be identified. During heating cycle, PDs were monitored and analyzed. At that time, the PDs were dependent on the temperature of the heating cycle and showed cyclic behaviors, which were attributed to local delamination of the interfaces, between epoxy unit and stress relief cone(SRC) and between SRC and cable, due to the difference of thermal expansion. As a conclusion, HFPD measurement technique was proven to be an effective diagnostic method for qualification of extra high voltage (EHV) cable accessories. With this technique, the optimal design of the components of the accessories could be verified not only in an early stage but also under operating condition. This technique would result in the improvement of the reliability of the EHV cable accessories.

  • PDF

단일 광섬유 격자와 Erbium과 Ytterbium 첨가된 광섬유를 이용한 스트레인 및 온도의 동시 측정 (Simultaneous Measurement of Strain and Temperature by use of Fiber Bragg Grating Written in an Erbium: Ytterbium-Doped Fiber)

  • 정재훈
    • 전기전자학회논문지
    • /
    • 제8권1호
    • /
    • pp.117-120
    • /
    • 2004
  • 단일 광섬유 격자와 Yb와 Er이 첨가된 광섬유를 이용한 스트레인 및 온도의 동시 측정을 시행하였다. 스트레인과 온도에 대해서 $1100\;{\mu}{\varepsilon}$ and $50-180\;^{\circ}C$ 범위에서 $55.8\;{\mu}{\varepsilon}$$3\;^{\circ}C$의 오차를 가지고 측정하였다. 본 센서의 소형 및 저가의 특성으로 미루어 볼 때 넓은 범위의 스트레인 센서로 활용가치가 높다고 사료된다.

  • PDF

Cold electronics based 128 temperature sensor interface with 14 leads for testing of high Tc superconducting cable

  • Gour, Abhay Singh;Thadela, S.;Rao, V.V.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권1호
    • /
    • pp.11-14
    • /
    • 2018
  • High Temperature Superconducting (HTS) power cables are capable of transmitting bulk power without any loss compared to conventional copper cables. The major challenge in the design of such HTS cables is the high stresses (electro-thermal/electro-mechanical) developed at high voltages, high currents and cryogenic temperatures. The safe and reliable operation of HTS cables involves lots of instrumentation for monitoring, measurement, control and safe operation. In principle, a four probe method for resistance (RTD PT-100) is used for temperature measurements at various locations of HTS cable. The number of connecting leads required for this is four times that of the number of sensors. The present paper discusses a novel way of connecting 128 RTD sensors with the help of only 14 leads using a cold electronics based multiplexer board. LabVIEW 11.0 software was used for interfacing and displaying the readings of all the sensors on computer screen.

Local Flow Speed Measurement Using Tunable AC Thermal Anemometry

  • Chung Won Seok;Kwon Ohmyoung;Lee Joon Sik;Choi Young Ki;Park Seungho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1449-1459
    • /
    • 2005
  • This paper shows the results of local flow speed measurement using tunable AC thermal anemometry, which is suitable for the accurate measurement of wide range flow speed. The measurement accuracy is verified through the comparison between the measurement data and the analytic solution of the sensor temperature oscillation in stationary fluid. The relation between the phase lag and the flow speed is experimentally investigated at various conditions. The measurement sensitivity for low flow speed improves in a low frequency region and that for high flow speed improves in a high frequency region. Also, the sensitivity increases with decreasing thermal conductivity of the surrounding fluid. The local flow speed could be measured as low as 1.5 mm/s and the highest measurement resolution was 0.05 mm/s in the range of 4.5 $\~$5.0 mm/s at 1 Hz in this experiment.

선팽창 온도특성에 의한 저밀도 폴리에틸렌의 유리 천이온도에 대한 고찰 (Investigation on glass transition temperature of low density polyethylene by the characteristics of temperature dependent linear expansion)

  • 김봉흡;강도열;김재환
    • 전기의세계
    • /
    • 제30권7호
    • /
    • pp.441-447
    • /
    • 1981
  • As a preceeding work for the study on dielectric characterstics of a kind of low density polyethylene introduced morphological change by mechanical method, glass transition temperature which is regarded as a macroscopic aspect for relaxation of molecular chain segments has been observed by means of temperature dependent dilatometric measurement. The origina specimen clearly shows two knees which correspond to two peaks (.gamma. and .betha. peak) in the intenal friction measurement, suggesting the existence of separated glass transition temperatures at 150.deg.k and 260.deg.k respectively. On the specimen irradiated to 100 Mrad both glass transition temperatures tend to shift towards high temperature sides because of crosslinking by irradiation. furthemore an evidence can be seen that radiation effect, even in amorphous phase, is also slelctive depending on slight morphological differences. The specimen extended to four times in length shows a peculiar nature such as negative linear thermal expansion coefficient increasing with temperature between 220.deg.k and ambient temperature and that this fact is interpreted by considering that c axis of the lattice aligns along the extended direction by drawing, further c axis inherently possesses the characteristics of negative linear thermal expansion coefficient. For the observations that the relatively small positive linear expansion on the specimen extended to ca. two times as well as the part below 220.deg.k of the specimen extended to four times, it is considered for the reason of the facts that the incompletely oriented region indicated as the middle part of Peterlin's model tends to restore partially to orginal arrangement-a kind of phase transition-as increasing with temperature.

  • PDF