• Title/Summary/Keyword: High Temperature Fluid

Search Result 920, Processing Time 0.026 seconds

Analysis of Cushion Mechanism with Relief Valve for High-Speed Pneumatic Cylinders (고속 공기압 실린더용 릴리프밸브형 쿠션기구의 특성 해석)

  • Kim, Do-Tae;Zhang, Zhong Jie
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.3
    • /
    • pp.95-103
    • /
    • 2010
  • This paper presents a simulation model of a double-acting high-speed pneumatic cylinder with a relief valve type cushion mechanism. The model predicts piston motion, mass flow rate, pressure and temperature time histories of cushion chamber. Of interest here is to investigate the cushioning effect of varying the piston and piston-rod diameter, cushion ring diameter and length, and stoke in cushion mechanism. As a result, this cushion mechanism is found to be adequate under high-speed driving of pneumatic cylinders. The simulation model proposed here will be very useful to analyze the dynamic characteristics and to improve or design the better cushion mechanism in high-speed pneumatic cushion cylinders.

Characteristics of Friction Torques and Lubrication in High Speed Angular Contact Ball Bearings (고속 앵귤러 콘택트 볼베어링의 마찰 토크 및 윤활 특성)

  • 반종억;김경웅
    • Tribology and Lubricants
    • /
    • v.13 no.4
    • /
    • pp.47-52
    • /
    • 1997
  • Friction torques, electrical contact resistances and bearing temperatures were measured on high speed angular contact ball beatings for the spindle of machine tools. The test bearings ran with oil-air lubrication at the thrust loads from 320 N to 1920 N and at the rotational speed of up to 12000 rpm. Electrical contact resistances between balls and races were measured to evaluate the formation of the lubricant film in the contact area. The test results with sufficient lubrication showed that the variations of friction torques were sensitive to the thrust loads and the rotational speeds, and that the friction torques were higher than those with insufficient lubrication. With insufficient lubrication and high thrust loads, the collapse of the lubricant film was detected even at a high rotational speed. It was concluded that these high speed beatings to run in condition of fluid lubrication should require monitoring not only the temperature increase of the bearing but also the lubricant film formation in contact areas resulting from the change in the applied load and the lubricant amount.

Application Examples of CFD at the Planning Stage of High-Rise Buildings

  • Hiroto, Kataoka;Yoshiyuki, Ono;Kota, Enoki;Yuichi, Tabata;Satoko, Kinashi
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.145-156
    • /
    • 2022
  • Application examples of computational fluid dynamics (CFD) in the planning stage of high-rise buildings are introduced. First, we introduce examples of applications in the environmental field. The pedestrian wind environment was one of the earliest practical examples of CFD. CFD was also employed to validate the heat island mitigation measures proposed as part of the new construction plan. Second, application examples of wind-force evaluations are introduced. Prediction examples are presented for the peak wind pressure around a complex-shaped building and the wind force evaluation for a base-isolated building. The results prove that the results of the proper execution of CFD are equivalent to those of the wind tunnel experiment. As examples of CFD applications of other issues related to high-rise building planning, we introduce snow accretion on outer walls and high-temperature exhaust from emergency generators. Finally, the future prospects for the use of CFD are discussed.

CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO (하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석)

  • Cho, SungHwan;Lee, JongHyeon;Kim, DaeYoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.327-336
    • /
    • 2020
  • The high-flux advanced neutron application reactor (HANARO) is a research reactor with thermal power of 30 MW applied in various research and development using neutrons generated from uranium fission chain reaction. A degasifier tank is installed in the ancillary facility of HANARO. This facility generates gas pollutants produced owing to internal environmental factors. The degasifier tank is designed to maintain the gas contaminants below acceptable levels and is monitored using an analyzer in the gas sampling panel. If condensate water is generated and flows into the analyzer of the gas sampling panel, corrosion occurs inside the analyzer's measurement chamber, which causes failure. Condensate water is generated because of the temperature difference between the degasifier tank and analyzer when the gas flows into the analyzer. A heating system is installed between the degasifier tank and gas sampling panel to suppress condensate water generation and effectively remove the condensate water inside the system. In this study, we investigated the efficiency of the heating system. In addition, the variations in the pipe temperature and the amount of average condensate water were modeled using a wall condensation model based on the changes in the fluid inlet temperature, outside air temperature, and heating cable-setting temperature.

Design and Evaluation of Ultrasonic Flow Meter for High Temperature by Using Finite Element Method (유한요소법을 이용한 고온용 초음파 유량센서의 설계 및 평가)

  • Lee, Joo-Hee;Kim, Chang-Il;Paik, Jong-Hoo;Cho, Jeong-Ho;Jeong, Young-Hun;Lee, Young-Jin;Nahm, Sahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.859-864
    • /
    • 2011
  • An operation temperature of $Pb(Zr,Ti)O_3$ based piezoelectric ultrasonic flowmeter was generally restricted to below 200$^{\circ}C$ due to a low depoling temperature of its ceramic material. Thus, a new designed piezoelectric ultrasonic flowmeter was fabricated in order to protect from the extremely hot fluid. Its structure is optimized by a finite element method to effectively stop heat flowing along a waveguide. Various materials such as Cu, Al, SUS were examined as a multi-plate radiation shield to enhance the performance of piezoelectric ultrasonic flowmeter. The SUS was evaluated as the most effective material to enhance the performance of piezoelectric ultrasonic flowmeter. As the number of plates of the radiation shield increased, the temperature at piezoelectric transducer away from the hot fluid was constantly decreased with a ratio of 3.12$^{\circ}C$ per the plate number.

Lubrication Analysis of Parallel Slider Bearing with Nanolubricant (나노윤활유를 사용하는 평행 슬라이더 베어링의 윤활해석)

  • TaeJo Park;JeongGuk Kang
    • Tribology and Lubricants
    • /
    • v.39 no.3
    • /
    • pp.87-93
    • /
    • 2023
  • Nanofluids are dispersions of particles smaller than 100 nm (nanoparticles) in base fluids. They exhibit high thermal conductivity and are mainly applied in cooling applications. Nanolubricants use nanoparticles in base oils as lubricant additives, and have recently started gathering increased attention owing to their potential to improve the tribological and thermal performances of various machinery. Nanolubricants reduce friction and wear, mainly by the action of nanoparticles; however, only a few studies have considered the rheological properties of lubricants. In this study, we adopt a parallel slider bearing model that does not generate geometrical wedge effects, and conduct thermohydrodynamic (THD) analyses to evaluate the effect of higher thermal conductivity and viscosity, which are the main rheological properties of nanolubricants, on the lubrication performances. We use a commercial computational fluid dynamics code, FLUENT, to numerically analyze the continuity, Navier-Stokes, energy equations with temperature-viscosity-density relations, and thermal conductivity and viscosity models of the nanolubricant. The results show the temperature and pressure distributions, load-carrying capacity (LCC), and friction force for three film-temperature boundary conditions (FTBCs). The effects of the higher thermal conductivity and viscosity of the nanolubricant on the LCC and friction force differ significantly, according to the FTBC. The thermal conductivity increases with temperature, improving the cooling performance, reducing LCC, and slightly increasing the friction. The increase in viscosity increases both the LCC and friction. The analysis method in this study can be applied to develop nanolubricants that can improve the tribological and cooling performances of various equipment; however, additional research is required on this topic.

Design of partial emission type liquid nitrogen pump

  • Lee, Jinwoo;Kwon, Yonghyun;Lee, Changhyeong;Choi, Jungdong;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.64-68
    • /
    • 2016
  • High Temperature Superconductor power cable systems are being developed actively to solve the problem of increasing power demand. With increases in the unit length of the High Temperature Superconductor power cable, it is necessary to develop highly efficient and reliable cryogenic pumps to transport the coolant over long distances. Generally, to obtain a high degree of efficiency, the cryogenic pump requires a high pressure rise with a low flow rate, and a partial emission type pump is appropriate considering its low specific speed, which is different from the conventional centrifugal type, full emission type. This paper describes the design of a partial emission pump to circulate subcooled liquid nitrogen. It consists of an impeller, a circular case and a diffuser. The conventional pump and the partial emission pump have different features in the impeller and the discharge flow passage. The partial emission pump uses an impeller with straight radial blades. The emission of working fluid does not occur continuously from all of the impeller channels, and the diffuser allows the flow only from a part of the impeller channels. As the area of the diffuser increases gradually, it converts the dynamic pressure into static pressure while minimizing the loss of total pressure. We used the known numerical method for the optimum design process and made a CFD analysis to verify the theoretical performance.

The use of fluid inclusions to constrain P-T-X conditions of formation of Eonyang amethyst (언양 자수정 형성 환경의 압력-온도-성분에 대한 유체포유물의 이용)

  • K. H. Yang
    • The Journal of the Petrological Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1996
  • Eonyang amethyst deposits are thought to be spatially and temporally associated with the biotite granite of the Kyeongsang Basin. The examined euhedral quartz crystals in cavities in the aplite intruded biotite granite are colored-zoned from white at the base to amethystine at the tops. Three types of primary Inclusions were observed and three is representing each types are constructed to constrain the trapping conditions and fluid evolution involved during the formation of the amethyst. The intersection of the isochore representing the early fluid inclusions with solidus temperature of the host granite indicates initial quartz formation at about $600^{\circ}C$ and 1.0-1.5 kbars . Intermediate quartz formation, associated with the high-salinity inclusions, occurred at somewhat lower temperatures ($400^{circ}c$) and pressures of about 1 kbar. The amethystine quartz formed from $H_2O$-$CO_2$-NaCl fluids at temperatures between 280-$400^{circ}c$ and pressures of about 1 kbar. Early quartz is interpreted to have formed from fluids that either exsolved from or were in equilibrium with the granite at near solidus conditions, whereas the amethystine quartz apparently grew from fluids of at least partial sedimentary origin.

  • PDF

Analysis of the Dynamic Characteristics of a HDD Spindle System Supported by Asymmetrically Grooved Journal Bearings (비대칭 그루브 저널 베어링으로 지지되는 하드디스크 스핀들 시스템의 동특성 해석)

  • 이상훈;김학운;장건희;김철순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.748-752
    • /
    • 2004
  • Fluid dynamic bearings (FDBs) have been replacing ball bearings of the HDD spindle motor very rapidly. But there are several demerits of HDB, such as high friction torque, variable viscosity of the fluid lubricant depending on operating temperature, low stiffness, and etc. Eccentricity is one of the major parameters which affects the static and dynamic characteristics. As the static eccentricity is larger, the stiffness and the damping coefficients become bigger. But friction torque is relatively unaffected by the static eccentricity. This research proposes a new type of journal bearing with asymmetric journal grooves which results in better dynamic characteristics. The static and dynamic characteristics of the new journal bearing are investigated by solving the Reynolds' equation with FEM, and the transient analysis is performed to predict the dynamic behavior of rotor by solving the equations of motion of a HDD spindle system with Runge-Kutta method. The result shows that the proposed Journal bearings have much bigger stiffness and damping coefficients compared with the conventional symmetric ones. And consequently, it has smaller whirl radius and tilting angle.

  • PDF

Analysis on the Thermal Performance of Flat-plate Solar Collector for Greenhouse Heating(I) (온실 난방을 위한 평판형 태양집열기의 열적성능 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Lee, Seung-Hwan;Lee, Suk-Gun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.6
    • /
    • pp.46-56
    • /
    • 1998
  • This study was performed to investigate thermal performances of two different types of flat-plate solar collector systems; natural circulation system and forced circulation system. Conclusions obtained from this study are summarized as follows; 1) In the natural circulation system, the total heat amounts retrieved by starting recovery soon after sunrise were ranged from 10.28 to 17.20MJ/m$^2$, while the total heat amounts retrieved by starting recovery after sunset were ranged from 5.31 to 10.77MJ/m$^2$. 2) The collector efficiency in natural circulation system were ranged from 51.1% to 54.1% when the collected heat was retrieved after sunrise and were 65.8~78.0% when the collected heat was retrieved soon after sunset. 3) According to the regression analysis between fluid flow rates and fluid temperature difference at inlet and outlet of collector pipe, there was high regressive corelations with regression coefficient, r, of 0.982. 4) The collector efficiencies estimated for forced circulation system were 73.1~88.6%, and 78.4~94.8%, and 64.2%~74.5%, respectively when fluid circulation rates were 4.2 l/min, and 7.0 l/min, respectively.

  • PDF