• 제목/요약/키워드: High Power-Factor

검색결과 1,907건 처리시간 0.031초

단일 전류 센서를 이용하는 새로운 브리지 없는 인터리빙 방식의 역률 보상 회로 (A Novel Bridgeless Interleaved Power Factor Correction Circuit with Single Current Sensor)

  • 도안반투안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.363-364
    • /
    • 2016
  • In this paper, a novel bridgeless interleaved power factor correction circuit with single current sensor is proposed. The proposed control strategy requires only one current sensor for the interleaved bridgeless PFC. By sampling the output current, all the boost indictor currents can be calculated and used to control the input current according to the input voltage. The reduced number of current sensors and associated feedback circuits helps reduce the cost of system. The problem caused by the unequal current gain between current sensors inherently does not exist in the proposed topology. Thus, current sharing between converters can be achieved more accurately and the high frequency distortion is decreased. In addition, the proposed technique can be applied to the other kinds of interleaved PFC topologies. Performance of the proposed control strategy is verified by the experimental results with 6.6kW bridgeless interleaved PFC circuit.

  • PDF

입력 전류의 측정이 필요없는 Boost 컨버터의 역률 보정에 관한 연구 (A Study On The Power Factor Correction Of The Boost Converter Without The Input Current Measurement)

  • 조상준;이광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 1996
  • This paper presents a new PFC control method which replaces a fast line current measurement with a filtered load current measurement. Using the power balance relation between the input and the output of the boost converter. the input current can be described as the function of load current. Thus the PWM signal which effects the switching control of the boost converter is generated using the PFC input voltage, the PFC output voltage and the load current as input variables. By using a filter between the bridge rectifier and a dc-to-dc converter, the input voltage of the dc-to-dc converter is forced to always maintain above zero volt. Then the input current traces a sinewave in phase. The proposed scheme accomplishes a very high power factor and a low harmonic distortion of the line current. The validity of this scheme is demonstrated through simulation.

  • PDF

Active clamp 컨버터의 주파수 변조 제어 (Frequency modulation control for active clamp converter)

  • 백주원;손호섭;류명효;유동욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.73-76
    • /
    • 2003
  • A zero voltage soft switching inverter using active clamp is presented for induction heating application. This converter have long been attractive because of its simplicity, high efficiency, and low cost compared to other schemes. In addition to those merits, Input power factor can be improved with a variable frequency control. In this paper, it describe the control method and operational principle to improve a power factor with a single stage US converter using active clamp for induction heating application.

  • PDF

역률 개선과 출력 전압 조정을 위한 불연속 모드의 승압형 컨버터가 결합된 단일 전력단 포워드-플라이백 컨버터 (DCM Boost Converter Integrated Single-Stage Forward-Flyback Converter for Power Factor Correction and Output Voltage Regulation)

  • 이성세;강정일;구관본;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.119-123
    • /
    • 2001
  • In this paper, a DCM operated boost integrated single-stage forward-flyback converter is proposed. This proposed converter has high power factor, low harmonic distortion, and tight output regulation. To increase efficiency, zero voltage switching with asymmetrical control is used. This converter also give low voltage stress in switch and this results in low conduction loss with low turn-on resistance.

  • PDF

단일단 역률개선 회로를 이용한 인터리빙 (interleaving) 방식 AC/DC 컨버터 (An interleaved single-stage power-factor-correction AC/DC converter)

  • 김응호;권봉환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.547-550
    • /
    • 2004
  • An interleaved single-stage power-factor-correction (PFC) AC/DC converter is presented in this paper. The proposed converter is combined by two single-stage AC/DC converters based on flyback converter Each PFC stage operates in discontinuous conduction mode (DCM). By exploiting the interleaving technique, the input ripple current and output ripple voltage are reduced. The proposed converter complied with EN/1EC61000-3-2 harmonic regulations achieves high efficiency and low cost. The performance of the proposed converter was evaluated on a 180W $(90W\times2,\;24V,\;7.5A)$ experimental prototype.

  • PDF

단위 역률을 갖는 BIFRED 컨버터를 이용한 새로운 120Hz DC 출력 리플-전압 저감 제어 기법 (A New 120Hz DC Output Ripple-Voltage Suppression Scheme Using BIFRED Converter with Unity Power Factor)

  • 김정범;박남주;이동윤;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.542-546
    • /
    • 2004
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still shows generally good performance such as low THD of input line current and high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and small size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.

  • PDF

소프트 스위칭 Single Stage AC-DC Full Bridge Boost 컨버터 (Soft Switching Single Stage AC-DC Full Bridge Boost Converter)

  • 김은수;조기연;김윤호;조용현;박경수;안호균;박경수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.493-496
    • /
    • 1999
  • A new soft switching single stage AC-DC full bridge boost converter with unit input power factor and isolated output is presented in this paper. Due to the use of a non-dissipative snubber on the primary side, a single stage high-power factor isolated full bridge boost converter has a significant reduction of switching losses in the main switching devices. The non-dissipative snubber adopted in this study consists of a snubber capacitor Cr, a snubber inductor Lr, a fast recovery snubber diode Dr, and a commutation diode Dr, and a commutation diode Dp. This paper presents the complete operating principles, theoretical analysis and experimental results.

  • PDF

형광등용 전자식 안정기에 적합한 수동 역률개선회로의 제안 및 특성 개선에 관한 연구 (Improved Passive Power Factor Correction Circuits of Electronic Ballasts for fluorescent lamps)

  • 채균;류태하;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2795-2797
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

A Preliminary Study on the Communication Effect on Team Performance in Main Control Room of SMART

  • Heo, Eun Mee;Byun, Seong Nam
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.97-106
    • /
    • 2013
  • Objective: The aim of this study is to investigate the attributing factors influencing team performance. Background: Technically, it is necessary that operators adapt themselves to computerized and advanced techniques to operate the main control rooms safely in nuclear power plant in Korea. The more main control rooms are digitalized, the more important for operators to have high team performance it is. Method: This paper analyzes team process through literatures review and elicits team performance shaping factor. Especially, the objective of this research is to elicit communication using common team performance shaping factors. Results: This study has found communication through team performance shaping factors in Main Control Room of the SMART. Conclusion: This paper can offer a starting point for team communication, which can use team performance shaping factor framework that are emerging in these new nuclear power plant. Application: As a result, I expect that the evaluation communication for MCR operator's team performance will lead the operating techniques in nuclear power industry internationally.

TWO-SWITCH BOOST CHOPPER-BASED PFC RECTIFIER FOR ELECTRONIC BALLAST

  • Takhashi, Nobuo;Okutsu, Kenzo;Kato, Yoshito;Ohkita, Masaaki;Matsuyama, Makoto;Nakaoka, Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.993-997
    • /
    • 1998
  • This paper presents a two-switch boost chopper with a sinewave current shaping and power factor correction scheme, which is applied for driving electronic ballast using high frequency resonant inverter. A working principle of the proposed one-converter type electronic ballast with power factor correction and active filtering schemes is described on the bases of the equivalent circuit of each operation mode, together with operation analysis. The steady-state performance evaluations of this electronic ballast are illustrated and discussed in experiment.

  • PDF