• 제목/요약/키워드: High Frequency noise

검색결과 2,056건 처리시간 0.115초

콘크리트 궤도 터널 내 KTX 차량의 실내소음 특성 분석 (Analysis of Interior Noise for KTX in Tunnel with Concrete Track)

  • 김재철;이찬우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.25-28
    • /
    • 2005
  • The interior noise of KTX in tunnel is becoming the problem since the commercial operating in April 2004. The major sources of interior noise for High speed train ate known as the aerodynamic noise and rolling noise generally. We measure the noise and vibration inside KTX in tunnel in order to find the cause of the interior noise of KTX. The analysis results show that the interior noise of KTX in tunnel with concrete track is increased sharply by a low frequency below 80Hz that is the natural frequency of the KTX carbody. We know that the booming noise inside KTX in tunnel with concrete track is generated by aerodynamic noise outside ganqway and rolling noise at the carbody natural frequency.

  • PDF

조합형 소음기를 이용한 박용 디젤 엔진 배기 소음 제어 (Exhaust Noise Control of Marine Diesel Engine Using Hybrid Silencer)

  • 이태경;주원호;배종국
    • 한국소음진동공학회논문집
    • /
    • 제19권7호
    • /
    • pp.679-684
    • /
    • 2009
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are ineffective to control exhaust noise because of low absorption in the low frequency range. In the paper, exhaust noise control of marine diesel engine was studied by using the hybrid silencer, which was composed of virtually divided array of concentric hole-cavity resonators and conventional absorptive silencer. A series of tests including field tests were performed to investigate the acoustic performance of the hybrid silencer. Consequently, its high performance of 5${\sim}$10 dB noise reduction in the low frequency range was confirmed and it is expected to be very helpful in reducing the exhaust noise of marine diesel engine.

고속철도 소음원의 위치규명에 관한 고찰 (Investigation of noise source localization on High speed train)

  • 고효인;유원희;이준석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1590-1597
    • /
    • 2007
  • This paper deals with the noise source localization of the Korean High Speed Train (KTX) at the speed of 300 km/h. Using Microfonarray system and beamforming technology typical pass-by noise sources and their frequency characteristics are investigated. It is primarily aimed at investigating the location and characteristics of the high speed train emission. The results from the microphone array tests are also analyzed in relation to the remarks from analytic studies and experimental investigations on the high speed train that have been done with the intention of understanding the interior noise mechanism. The acoustical image shows the low frequency noise sources mainly at the position of the under part of the train at high speeds and the related source mechanism are discussed.

  • PDF

Noise reduction method using a variance map of the phase differences in digital holographic microscopy

  • Hyun-Woo Kim;Myungjin Cho;Min-Chul Lee
    • ETRI Journal
    • /
    • 제45권1호
    • /
    • pp.131-137
    • /
    • 2023
  • The phase reconstruction process in digital holographic microscopy involves a trade-off between the phase error and the high-spatial-frequency components. In this reconstruction process, if the narrow region of the sideband is windowed in the Fourier domain, the phase error from the DC component will be reduced, but the high-spatial-frequency components will be lost. However, if the wide region is windowed, the 3D profile will include the high-spatial-frequency components, but the phase error will increase. To solve this trade-off, we propose the high-variance pixel averaging method, which uses the variance map of the reconstructed depth profiles of the windowed sidebands of different sizes in the Fourier domain to classify the phase error and the high-spatial-frequency components. Our proposed method calculates the average of the high-variance pixels because they include the noise from the DC component. In addition, for the nonaveraged pixels, the reconstructed phase data created by the spatial frequency components of the widest window are used to include the high-spatialfrequency components. We explain the mathematical algorithm of our proposed method and compare it with conventional methods to verify its advantages.

직류 계전기의 접촉구조에 의한 고주파수 소음저감 (Towards reducing acoustical high-frequency noise of a direct current relay via contact structure)

  • 양준혁;원종섭;김원진
    • 한국음향학회지
    • /
    • 제41권6호
    • /
    • pp.691-697
    • /
    • 2022
  • 직류 계전기는 전기자동차의 하나의 부품으로 간헐적으로 고주파수 소음이 710 Hz ~ 730 Hz의 주파수 범위에서 전기적 부하에 의해 발생한다. 고정접점과 가동접점 사이에서 발생하는 전자 반발력이 가동접점과 접압 스프링을 진동시키고, 그 진동으로 가동접점과 접압 스프링에 공진이 발생하여 고주파수 소음이 발생한다. 본 논문에서는 수치해석 및 실험을 통하여 고주파수 소음의 원인을 규명하고, 소음을 제거하는 방안을 제시하였다. 710 Hz ~ 730 Hz의 주파수 범위에서 가동접점은 고정접점과의 2개의 접촉점을 기준으로 회전하는 공진모드가 발생한다. 따라서 해당 여기서 제안한 방법은 공진모드를 제거하기 위해 가동접점의 구조를 2점 접촉구조 방식에서 3점 접촉구조 방식으로 변경하는 것이다. 3점 접촉구조를 적용함에 따라 공진모드가 제거되는 것을 수치해석으로 확인하였고, 실험적으로도 고주파수 소음이 발생하지 않는 것을 확인하였다.

파워흐름경계요소법을 이용한 중고주파 소음해석 소프트웨어 'NASPFA' 개발 (Development of Noise Analysis Software-'NASPFA' in Medium-to-high Frequency Ranges using Power Flow Boundary Element Method)

  • 이호원;홍석윤;권현웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.949-953
    • /
    • 2004
  • In this paper, Power Flow Boundary Element Method(PFBEM) is studied as the numerical method for the vibration and sound predictions of complex structures in medium-to-high frequency ranges. NASPFA, the sound analysis software based on PFBEM, is developed and is used for the vibro-acoustic analysis. And also the developed software is used for the prediction of interior and exterior sound fields of vibrating structures and for the analysis of the multi-domain problems. To verify the accuracy, NASPFA is applied to the prediction of the energy distribution in the simple structures, and its results are compared with exact PFA solutions. And various practical vehicle systems are modeled and the distributions of the acoustical energy density are successfully predicted.

  • PDF

Speckle Noise Reduction for 3D Power Doppler Ventricle Image Restoration Using Wavelet Packet Transform

  • Jung, Eun-sug;Ryu, Conan K.R.;Hur, Chang Wu;Sun, Mingui
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.156-159
    • /
    • 2009
  • Speckle noise reduction for 3D power doppler ventricle coherent image for restoration and enhancement using wavelet packet transform with separated thresholding is presented. Wavelet Packet Transform divide into low frequency component image to high frequency component image to be multi-resolved. speckle noise is located on high frequency component in multiresolution image mainly. A ventricle image is transformed and inversed with separated threshold function from low to high resolved images for restoration to be utilize visualization for ventricle diagnosis. The experimental result shows that the proposed method has better performance in comparison with the conventional method.

  • PDF

전달함수를 이용한 차실 소음의 부분구조 해석 (Frequency Response Function Based Substructural Analysis of Interior Noise)

  • 황우석;이두호
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.480-485
    • /
    • 2000
  • This paper presents the application of the substrctural analysis based on the frequency responses for the prediction of the interior noise in a car. The complex trimmed body with the high modal density is presented by the experimental data. Finite element model presents the powertrain and its subframes with the lower modal density. The substructural analysis based on the frequency responses combines the frequency response functions from the numerical analysis and the experiments. It describes the interior noise successwfully. Using this method we can pick up the most dominant paths for the booming noise and predict the effects of the design changes easily.

  • PDF

노이즈 차폐 변압기의 주파수 특성 분석 (A analysis of frequency characteristics for the noise cut transformer)

  • 김명석;오준식;조현길;한규환;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.957-959
    • /
    • 2005
  • A noise reduction equipment in power systems was device combined in a passive element such as the form of L, R and C. A analysis of frequency characteristics for the transformer models shall be considered the additional capacitance between the windings($C_{ps}$), terminals($C_s$), and winding-ground($C_g$). A noise in transformer is modeled by take account into the different frequency. In case of the high frequency, transformer windings with stray capacitance have lower impedance. Therefore a noise is transferred from primary winding to secondary winding. Noise Cut Transformer(NCT) was the noise reduction device and was normally single phase two-winding type transformer. We analyzed frequency characteristics using the nodal network analysis with the equivalent circuit and the simulation of the MATLAB.

  • PDF

산업장 소음의 강도 및 주파수 특성에 관한 조사연구 (The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites)

  • 김광종;차철환
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF