• 제목/요약/키워드: High Flow Rate

검색결과 3,264건 처리시간 0.033초

추적자를 이용한 유량 측정 (Measurement of Water Flow in Closed Conduits by Chemical Tracer Method)

  • 이선기;정백순;김창호
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.19-26
    • /
    • 1999
  • Thermal output in a nuclear power plant is verified with calorimetric heat balance on the secondary plant. The calorimetry involves the precise measurement of the feedwater flow rate. However, the correct indication of feedwater flow rate obtained by a pressure-difference measurement across a venturi can be affected by instrument errors, fouling or a poorly developed velocity profile. This can result in an inaccurate mass flow rate and consequently an inaccurate estimate of power. The purpose of this study is to develop verification methods with accuracy better than $0.5\%$ for high precision flow measurement to be used for measuring feedwater flow rate. This chemical tracer method is a testing process that uses tracers which can be applied to quantify losses in electrical output due to the incorrect measurements of feedwater flow rate. And this system has good response to the variation of the flow rate. Accuracy of better than 0.5 percent can be expected for feedwater flow measurement, providing that the system can be stabilized during the test. This methodology is applicable to other flow systems well.

  • PDF

대구지방 하천의 집중 강우후의 수계환경의 변화 (Environmental Changes of the Rivers in Taegu Area after a Heavy Rain)

  • Lyu, Seung-Won;Song, Seung-Dal
    • The Korean Journal of Ecology
    • /
    • 제6권2호
    • /
    • pp.81-89
    • /
    • 1983
  • The change of environmental factors with flow rates were studied quantitatively for two rivers, the Nakdong River and the Sin stream, which have different basins in ecosystem structures, during short period after a heavy rain. In the Nakdong River, transparency, DO, alkalinity and hardness were negatively correlated with the flow rate by logarithmic function, but the concentration of SiO2 was relatively constant regardless of the flow chage. In the Sin stream, transparency, alkalinity, hardness and the concentration of NH3-N, NO2-N and SO4= showed negative correlation with the flow rate by logarithmic function. The ratios of maximum to minimum values for aquatic environmental factors during the samller than that for flow rate in the respective rivers (28 in the Nakdong R.; 50 in the Sin S.). Immediately after the heavy rain, the concentrations of NO2-N, NH3-N and PO4-P in the Sin stream were 8, 6 and 1 times as high as those in the Nakdong River, respectively, but in the stable flow state, those became 94, 25 and more than 10 times, respectively. The load for most of the dissolved environmental constituents changed similarly to the flow rate in both rivers. It is notable that, at the stable flow state, the loads for NH3-N (59g/sec) and NO2-N (3.3g/sec) in the Sin stream were 4.3 and 1.3 times as high as those in the Nakdong River.

  • PDF

Analysis on the performance and internal flow of a tubular type hydro turbine for vessel cooling system

  • Chen, Zhenmu;Kim, Joo-Cheong;Im, Myeong-Hwan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1244-1250
    • /
    • 2014
  • The temperature of the main engine cabin of commercial vessel is very high. The material SS-316L undergoes creep damage at temperatures exceeding $450^{\circ}C$. It is essential to maintain the highly stressed engine cabin below the creep regime. Hence, seawater is employed in this kind of maritime vehicles as cooling liquid. It obtains the thermal energy at the cooling pipe line after passing through main engine cooling system. To harness the energy in the seawater, a turbine can be installed to absorb the energy in the seawater before being released into the sea. In this study, a cooling pipe line is selected to apply the tubular type hydro turbine for transferring the energy. Numerical analysis for investigating the performance and the internal flow characteristics of the tubular turbine is conducted. The results show that the maximum efficiency of 85.8% is achieved although the efficiency drops rapidly at partial flow rate condition. The efficiency descends slowly at the condition of excess flow rate. There is a relatively wide operating range of flow rate of this turbine to keep high efficiency at the excess flow rate condition. For the internal flow of the turbine, there is uniform streamline on the suction and pressure sides of the blade at the design point. However, the secondary flow appears at the suction and pressure sidesat the excess flow rate.In addition, it appears only at pressure side at the partial flow rate condition.

지중 순환수 유량 변화에 따른 지열원 히트펌프 시스템의 성능 특성 연구 (Influence of the Secondary Fluid Flow Rate on the Performance of a GSHP System)

  • 이준엽;정진택;우정선;최종민
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.649-656
    • /
    • 2010
  • The aim of this study is to investigate the influence of the secondary fluid flow rate through GLHX on a GSHP system with vertical single U-tube type GLHXs. The COP of a GSHP system with large flow rate was lower than it with small flow rate due to large power consumption of ground loop circulating pump. It is suggested that the heat pump unit with high COP and low flow rate through the GLHX have to be selected in order to enhance the performance of the system and reduce the length of GLHX.

Experimental Study on Adjustment of Inlet Nozzle Section to Flow Rate Variation for Darrieus-type Hydro-Turbine

  • Watanabe, Satoshi;Shimokawa, Kai;Furukawa, Akinori;Okuma, Kusuo;Matsushita, Daisuke
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권1호
    • /
    • pp.30-37
    • /
    • 2012
  • A two dimensional Darrieus-type turbine has been proposed for the hydropower utilization of extra-low head less than 2m. In a practical use of Darrieus-type hydro-turbine, head and flow rate may be varied temporally and seasonally. Considering that the cost advantage is required for the low head hydro turbine system, the Darrieus turbine should be operated with high efficiency in the wider range of flow rate possibly by using an additional device with simpler mechanism. In the present paper, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed to obtain the preferable inlet velocity in low flow rate conditions. Effects of resulting spanwise partial inlet flow are investigated. Finally, an effective modification of inlet nozzle height over flow rate variation is shown.

연속발진 고출력 화학레이저 구동용 이젝터 시스템 연구 (Study of Ejector System for cw High Power Chemical Lasers Operating)

  • 김세훈;진정근;권세진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1715-1719
    • /
    • 2004
  • An in-house supersonic ejector was designed to ensure low pressure and high speed scavenging of resonating cavity of chemical lasers. For given primary flow condition, 100g/s secondary mass flow rate was observed at the design pressure. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of diffuser at the secondary inlet further reduced diffuser upstream pressure to 1/4-1/5 relieving the local to the primary supply unit. In order to increase the secondary flow, we put two ejectors capable of removing 50g/s each of secondary flows together to deal with higher mass flow. Test of the parallel unit demonstrated the secondary flow rate was proportional to the numbers of individual units that were brought together. Additionally, flow calculations with a commercial code were carried out in every case of experiment and compared with results.

  • PDF

평판에 분사된 분무충돌제트의 냉각특성에 대한 실험적 연구 (An experimental study on cooling characteristics of mist impinging jet on a flat plate)

  • 전상욱;정원석;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.528-533
    • /
    • 2001
  • An experimental study is carried out to investigate the effects of air and water mass flow rates on cooling characteristics of mist impinging jet on a flat plate. Experiments are conducted with air mass flow rates from 0.0 to 3.0 g/s, and water mass flow rates from 5.0 to 20.0 g/s. An air-atomizing nozzle is used for the purpose of controlling air and water mass flow rates. In this study, a new test section is designed to obtain local heat transfer coefficient distributions. Heat transfer characteristics of the mist impinging jet are explained with the aid of flow visualization. Surface temperature and heat transfer coefficient distributions become more uniform as air mass flow rate increases, and that the increases in water flow rate mainly enhance cooling performance. Air mass flow rate weakly influences averaged heat transfer coefficient when water mass flow rate is low, but averaged heat transfer coefficient increases remarkably as air mass flow rate in case of high water mass flow rate.

  • PDF

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

유황분석과 수질변화 평가를 통한 비점오염원 관리대상지역 선정방법 연구 (Watershed Selection for Diffuse Pollution Management Based on Flow Regime Alteration and Water Quality Variation Analysis)

  • 정우혁;이상진;김건하;정상만
    • 한국물환경학회지
    • /
    • 제27권2호
    • /
    • pp.228-234
    • /
    • 2011
  • The goal of water quality management on stream and watershed is to focus not on discharged loads management but on a water quality management. Discharged loads management is not goal of water quality management but way for perform with total maximum daily loads management. It is necessary to estimate the relation between non-point source with stromwater runoff (NPSSR) and water quality to select a watershed where it is required to manage NPSSR for water quality improvement. To evaluate the effects of NPSSR on stream's water quality, we compare the aspects of water quality in dry and wet seasons using flow duration curve analysis based on flow rate variation data by actual surveying. In this study we attempt to quantify the variation characteristic of water quality and estimate the Inflow characteristic of pollution source with water quality and flow rate monitoring on 10 watersheds. We try to estimate water quality and flow rate by regression analysis and try again regression analysis with each high and low water quality data more than estimations. An analysis of relation between water quality and flow rate of 10 watersheds shows that the water quality of the Nonsan and the Ganggyeong streams had been polluted by NPSSR pollutants. Other eight streams were important point source more than NPSSR. It is wide variation range of $BOD_5$ also high average concentration of $BOD_5$. We have to quantify water quality variation by cv1 in wet season and cv365 in dry season with comparing the estimate of high water quality and low water quality. This method can be used to indicator for water quality variation according to flow rate.

Transition temperatures and upper critical fields of NbN thin films fabricated at room temperature

  • Hwang, T.J.;Kim, D.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.9-12
    • /
    • 2015
  • NbN thin films were deposited on thermally oxidized Si substrate at room temperature by using reactive magnetron sputtering in an $Ar-N_2$ gas mixture. Total sputtering gas pressure was fixed while varying $N_2$ flow rate from 1.4 sccm to 2.9 sccm. X-ray diffraction pattern analysis revealed dominant NbN(200) orientation in the low $N_2$ flow rate but emerging of (111) orientation with diminishing (200) orientation at higher flow rate. The dependences of the superconducting properties on the $N_2$ gas flow rate were investigated. All the NbN thin films showed a small negative temperature coefficient of resistance with resistivity ratio between 300 K and 20 K in the range from 0.98 to 0.89 as the $N_2$ flow rate is increased. Transition temperature showed non-monotonic dependence on $N_2$ flow rate reaching as high as 11.12 K determined by the mid-point temperature of the transition with transition width of 0.3 K. On the other hand, the upper critical field showed roughly linear increase with $N_2$ flow rate up to 2.7 sccm. The highest upper critical field extrapolated to 0 K was 17.4 T with corresponding coherence length of 4.3 nm. Our results are discussed with the granular nature of NbN thin films.