• Title/Summary/Keyword: High Energy Electron Beam

Search Result 284, Processing Time 0.054 seconds

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF

Effects of the Electroless Ni-P Thickness and Assembly Process on Solder Ball Joint Reliability (무전해 Ni-P 두께와 Assembly Process가 Solder Ball Joint의 신뢰성에 미치는 영향)

  • Lee, Ji-Hye;Huh, Seok-Hwan;Jung, Gi-Ho;Ham, Suk-Jin
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.60-67
    • /
    • 2014
  • The ability of electronic packages and assemblies to resist solder joint failure is becoming a growing concern. This paper reports on a study of high speed shear energy of Sn-4.0wt%Ag-0.5wt%Cu (SAC405) solder with different electroless Ni-P thickness, with $HNO_3$ vapor's status, and with various pre-conditions. A high speed shear testing of solder joints was conducted to find a relationship between the thickness of Ni-P deposit and the brittle fracture in electroless Ni-P deposit/SAC405 solder interconnection. A focused ion beam (FIB) was used to polish the cross sections to reveal details of the microstructure of the fractured pad surface with and without $HNO_3$ vapor treatment. A scanning electron microscopy (SEM) and an energy dispersive x-ray analysis (EDS) confirmed that there were three intermetallic compound (IMC) layers at the SAC405 solder joint interface: $(Ni,Cu)_3Sn_4$ layer, $(Ni,Cu)_2SnP$ layer, and $(Ni,Sn)_3P$ layer. The high speed shear energy of SAC405 solder joint with $3{\mu}m$ Ni-P deposit was found to be lower in pre-condition level#2, compared to that of $6{\mu}m$ Ni-P deposit. Results of focused ion beam and energy dispersive x-ray analysis of the fractured pad surfaces support the suggestion that the brittle fracture of $3{\mu}m$ Ni-P deposit is the result of Ni corrosion in the pre-condition level#2 and the $HNO_3$ vapor treatment.

Fast liquid crystal switching performance on indium zinc oxide films with low curing temperature via ion-beam irradiation (이온빔 조사된 저온 소성 인듐 아연 산화막을 이용한 액정의 고속 스위칭 특성 연구)

  • Oh, Byeong-Yun
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.904-909
    • /
    • 2019
  • Using the ion-beam irradiated indium zinc oxide (IZO) films which was cured at $100^{\circ}C$, uniform LC and homogeneous alignment of liquid crystal (LC) molecules was achieved. The IZO film was deposited on the glass substrate at the curing temperature of $100^{\circ}C$ and irradiated by the ion-beam which is an LC alignment method. To verify the LC alignment characteristics, polarizing optical microscope and the crystal rotation method were used. Additionally, it was confirmed that the LC cell with the IZO films had an enough thermal budget for high-quality LC applications. Field emission scanning electron microscope was conducted as a surface analysis to evaluate the effect of the ion-beam irradiation on the IZO films. Through this, it was revealed that the ion-beam irradiation induced rough surface with anisotropic characteristics. Finally, electro-optical (EO) performances of the twisted-nematic cells with the IZO films were collected and it was confirmed that this cell had better EO performances than the conventional rubbed polyimide. Furthermore, the polar anchoring energy was measured and a suitable value for stable LC device operation was achieved.

Novel Design of Ultrashort Pulse Excimer Laser Amplifier System II (Temporal Gain Control and Phase Distortion/ASE Characteristics)

  • Lee, Young-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.4
    • /
    • pp.228-232
    • /
    • 2003
  • The previous design work for very large final amplifier pumped by electron beam module was described from the point of view of energy characteristics. In this work, the design problems for phase front distortion, ASE, and gain control in large aperture amplifier are presented in detail.

High Energy Electron Dosimetry by Alanine/ESR Spectroscopy (Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정)

  • Chu, Sung-Sil
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1989
  • Dosimerty based on electron spin resonance (ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to 1 Gy. In water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies $(6\~21MeV)$ and therapeutic dose levels (1~60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15 MeV were higher by$2\~5\%$ than those calculated by nominal energy $C_E$ factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator.

  • PDF

Recent Advances in Advanced Oxidation Processes

  • Huang, Chin-Pao
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1998.10a
    • /
    • pp.1-1
    • /
    • 1998
  • Advanced (Chemical) oxidation processes (AOP) differ from most conventional ones in that hydroxyl radical(OH.) is considered to be the primary oxidant. Hydroxyl radicalcan react non-selectively with a great number of organic and inorganic chemicals. The typical rate constants of true hydroxyl radical reactions are in the range of between 109 to 1012 sec-1. Many processes are possible to generate hydroxyl radical. These include physical and chemical methods and their combinations. Physical means involves the use of high energy radiation such as gamma ray, electron beam, and acoustic wave. Under an applied high energy radiation, water molecules can be decomposed to yield hydroxyl radicals or aqueous electrons. Chemical means include the use of conventional oxidants such as hydrogen peroxide and ozone, two of the most efficient oxidants in the presence of promoter or catalyst. Hydrogen peroxide in the presence of a catalyst such as divalent iron ions can readily produce hydroxyl radicals. Ozone in the presence of specific chemical species such as OH- or hydrogen peroxide, can also generate hydroxyl radicals. Finally the combination of chemical and physical means can also yield hydroxyl radicals. Hydrogen peroxide in the presence of acoustic wave or ultra violet beam can generate hydroxyl radicals. The principles for hydroxyl radical generation will be discussed. Recent case studied of AOP for water treatment and other environmental of applications will be presented. These include the treatment of contaminated soils using electro-Fenton, lechate treatment with conventional Ponton, treatment of coal for sulfur removal using sonochemical and the treatment of groundwater with enhanced sonochemical processes.

  • PDF

Effects of Electron Beam Irradiation on the Quality of Kochujang Powder (Electron Beam 조사가 고추장 분말의 품질에 미치는 영향)

  • Kwon, Hoon;Lee, Jung-Eun;Kim, Jeong-Sook;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.4
    • /
    • pp.655-662
    • /
    • 2000
  • Electron beam (EB) irradiation was applied to study microbial decontamination effects for kochujang powder by determining their microbiological and physicochemical qualities over gamma ray (GR) irradiation. The samples showed a high microbial population, such as 105~106 CFU/g of total aerobic bacteria, negative of yeasts & molds and coliforms. Total bacterial counts were decreased by 1~2 log cycles with EB irradiation at 5~7.5 kGy, and 10 kGy irradiation was enough to improve the microbiological quality by reducing populations to below 104CFU/g, which was similar to gamma energy. Such doses were effective for controlling the microbial growth in stored samples during storage for 4 months at room temperature. Decimal reduction doses (D10 value) on initial bacterial populations were 2.88~3.02 kGy in EB and 3.57~3.59 kGy in GR, which were influenced by initial populations and energy types applied. Based upon the above results, 7.5~10 kGy irradiation caused negligible changes in Hunter's color, capsaicin, fatty acid composition and organoleptic qualities. Considering the quality changes resulting from subsequent storage, such as a decrease in capsanthin content and an increase in TBA value in the samples, it is recommendable to irradiate kochujang powder at 7.5~10 kGy when used for food processing.

  • PDF

Characterization of GaN and InN Nucleation Layers by Reflection High Energy Electron Diffraction (RHEED에 의한 GaN, InN 핵생성층의 열처리 효과 분석)

  • Na, Hyunseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.29 no.3
    • /
    • pp.124-131
    • /
    • 2016
  • GaN and InN epilayers with nucleation layer (LT-buffer) were grown on (0001) sapphire substrates by radio-frequency plasma-assisted molecular beam epitaxy (RF-MBE). As-grown and annealed GaN and InN nucleation layers grown at various growth condition were observed by reflection high-energy electron diffraction (RHEED). When temperature of effusion cell for III source was very low, diffraction pattern with cubic symmetry was observed and zincblende nucleation layer was flattened easily by annealing. As cell temperature increased, LT-GaN and LT-InN showed typical diffraction pattern from wurtzite structure, and FWHM of (10-12) plane decreased remarkably which means much improved crystalline quality. Diffraction pattern was changed to be from streaky to spotty when plasma power was raised from 160 to 220 W because higher plasma power makes more nitrogen adatoms on the surface and suppressed surface mobility of III species. Therefore, though wurtzite nucleation layer was a little hard to be flattened compared to zincblende, higher cell temperature led to easier movement of III surface adatoms and resulted in better crystalline quality of GaN and InN epilayers.