• 제목/요약/키워드: High Concentration Dust

Search Result 290, Processing Time 0.028 seconds

Risk Assessment of Explosion of Mixed Dust Generated in Semiconductor Manufacturing (반도체 공정에서 발생하는 혼합분진의 폭발 위험성평가)

  • Park, Chang-Sup;Kim, Chan-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.474-478
    • /
    • 2018
  • The use of metals such as aluminum and titanium and the related industrial facilities have been continuously increasing to meet the requirements of the improvement of high-tech products due to the development of industry, and explosion of metal dust. Semiconductor process Metal dust is essential, but research is insufficient. The purpose of this study is to identify risk by analyzing the quantitative risk such as maximum explosion pressure and minimum explosion concentration applied international test standard in order to select the semiconductor process facilities handling dust and to predict possible risk of accidents.

Treatment of High Strength para-Nitrophenol using Fenton-like Oxidation Catalyzed by Steeler's Dust (제강분진을 촉매로 활용한 펜톤유사산화에 의한 고농도 para-Nitrophenol의 처리)

  • 배범한;정재훈;이성재;장윤영;박규홍;장윤석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.136-139
    • /
    • 2000
  • Fenton-like oxidation of para-nitrophenol(PNP) was studied using hydrogen peroxide iii combination with steeler's dust substituted for ferrous iron in Fenton's reaction. Various factors critical in the degradation of PNP were studied, including hydrogen peroxide dosage, concentration of steeler's dust. and initial pH. Experimental results showed that 1,000mg/L PNP and its oxidation intermediate could be mostly decomposed within 30m1n by 10g/L steeler's dust, 0.25% hydrogen peroxide, and initila pH of 3.0. The reaction rate constant (k) of CODcr concentration were calculated with the addition of steeler's dust(0.0059 min$^{-1}$ (g/L)$^{-1}$ ) and hydrogen peroxide(0.2965 min$^{-1}$ (%)$^{-1}$ ), respectively.

  • PDF

Bigdata Analysis of Fine Dust Theme Stock Price Volatility According to PM10 Concentration Change (PM10 농도변화에 따른 미세먼지 테마주 주가변동 빅데이터 분석)

  • Kim, Mu Jeong;Lim, Gyoo Gun
    • Journal of Service Research and Studies
    • /
    • v.10 no.1
    • /
    • pp.55-67
    • /
    • 2020
  • Fine dust has recently become one of the greatest concerns of Korean people and has been a target of considerable efforts by governments and local governments. In the academic world, many researches have been carried out in relation to fine dust, but the research on the economic field has been relatively few. So we wanted to know how fine dust affects the economy. Big data of PM10 concentration for fine dust and fine dust theme stock price were collected for five years from 2013 to 2017. Regression analysis was performed using the linear regression model, the generalized least squares method. As a result, the change in the fine dust concentration was found to have a effect on the related theme stocks' price. When the fine dust concentration increased compared to the previous day, the fine dust theme stocks' price also showed a tendency to increase. Also, according to the analysis of stock price change from 2013 to 2017 based on fine dust theme stocks, companies with large regression coefficients were changed every year. Among them, the regression coefficients of Monalisa were repeatedly high in 2014, 2015, 2017, Samil Pharmaceutical in 2015, 2016 and 2017, and Welcron in 2016 and 2017, and the companies were judged to be sensitive to the concentration of fine dust. The companies that responded the most in the past 5 years were Wokong, Welcron, Dongsung Pharmaceutical, Samil Pharmaceutical, and Monalisa. If PM2.5 measurement data are accumulated enough, it would be meaningful to compare and analyze PM2.5 concentration with independent variables. In this study, only the fine dust concentration is used as an independent variable. However, it is expected that a more clear and well-explained result can be found by adding appropriate additional variables to increase the explanatory power.

Cluster Analysis of PM10 Concentrations from Urban Air Monitoring Network in Korea during 2000 to 2005 (전국 도시대기 측정망의 2000~2005년 PM10 농도 군집분석)

  • Han, Ji-Hyun;Lee, Mee-Hye;Ghim, Young-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.300-309
    • /
    • 2008
  • Variations in PM10 concentration between 2000 and 2005 from 84 urban air monitoring stations operated by the government were analyzed. The K-means cluster analysis was attempted using annual average and the 99th percentile of daily averages as parameters. The results obtained by excluding Asian dust episode days were compared with those obtained by using all available data. In any cases, the cluster with the highest mean concentration was mostly composed of stations in Seoul and Gyeonggi. Annual average of the cluster with the highest mean concentration showed a distinct decreasing trend, but that excluding Asian dust episode days did not show such a trend. Without Asian dust episode days high concentrations of monthly averages in March and April were also not observed. The effect of Asian dust was more pronounced in the 99th percentile of daily averages. The 99th percentile of daily averages of the cluster with the highest mean concentration was the highest in June following downs in April and May.

Production of air purification verification system using moss (이끼를 활용한 공기정화 검증 시스템 제작)

  • Ahn, Dohyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.587-591
    • /
    • 2019
  • Fine dust aerated in the atomsphere penetrates our lungs and blood lines through respiratory. Recent fine dust problems in Korea leads to development of various air purifiers. The researchers used this to study systems that could replace chemical filters. In order to compare the effect of the reduction of moss and conventional chemical filter(Hepa), a 1 cubic meter cube was prepared and the amount of the concentration of fine dust reduction was compared under controlled environment. Under the high concentration of fine dust, a test was done to figure out the reduction rate of the fine dust concentration by using air purification system with moss, hepa, and no filter. The air purification system(moss, hepa, and no filter) were operated 90 times in total, 30 times each. The test explains that the reduction of the fine dust amount and the rate of fine dust concentration. The results illustrate that the reduction of the amount fine dust was 138.93 after using air purification system with moss filter. In contrast, the usage of air purification system with hepa filter reduced the amount of fine dust to 76.57. And the air purification with no filter shows that the slight reduction of fine dust amount at 0.10. In the rate of fine dust concentration, moss filter was significantly higher than that of hepa, no filter (0.2379, 0.1298 and 0.0063 each). The results have confirmed that moss is effective in reducing fine dust concentration, and it is expected that with further improvement it can be used as a means to replace or supplement existing chemical filters in air purifier.

A study of flour dust explosion (사료분진의 폭발특성에 관한 연구)

  • Lee, Hong-Ju;Woo, In-Sung;Hong, Hyun-Kyoung;Sa, Min-Hyung;Kim, Yun-Seon;Hwhag, Myung-Whan;Hwang, Seong-Min;Park, Hee-Chul;Lee, Ju-Yup
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.4
    • /
    • pp.109-116
    • /
    • 2011
  • This study examined into property of flour dust explosion to get the basic data for safety of industry by protecting accident of dust explosion. The experiment was conducted to know the effect of distance between explodes in the experiment device, effect of flour dust concentration, effect of humidity, effect of explosion pressure to the dust concentration and effect of inactive substance additive. The study indicated that explosion was happened effectively at the optimum distance 100mm or less in inter-polar distance, and minimum ignition energy was measured at 6mm. The data of feed concentration to the probability of explosion showed that the smaller the particle diameter was, the larger probability of explosion was, and the higher the dust concentration was, the more increased the pressure of explosion was, but more than upper limit of dust concentration, then the explosion of pressure decreased. For the effect of humidity, the more it contained water, the more decreased the ignition energy of dust was, so increased minimum explosive concentration, and effective water content was minimum 10% or more. Inactive substance additive was effective in adding more than 15% CaCO3 and CaO as substance inhibiting dust explosion, in which CaCO3 was more effective than CaO. the analysis of the flame of dust explosion was performed by high-speed video camera, it showed the size of flame bacame smaller in order that sub feed, main feed, wheat powder. As a result, sub feed was expected to be less dangerous than others.

A Study on fine dust data collection and analysis using Drone (드론을 활용한 미세먼지 데이터 수집 및 분석에 관한 연구)

  • Kyoung-mok Kim;Ho-beom Jeon;Geun-Seun Lim
    • Journal of the Health Care and Life Science
    • /
    • v.9 no.2
    • /
    • pp.231-235
    • /
    • 2021
  • This study collects and provides environmental data related to weather by measuring the concentration levels of fine dust at different altitudes, with the aim of forecasting fine dust concentration changes, particularly in the areas where the vulnerable reside. Institutions in the healthcare-related fields can use the real-time data on the changing fine dust concentration, which is collected through different combinations of various measuring devices and drone technologies, which have recently developed at a rapid pace. The study first collects data on the following: PM1 (fine dust particles <1 ㎛ in size), PM2.5 (fine dust particles <2.5 ㎛ in size), and PM10 (fine dust particles <10 ㎛ in size) and predicts respective changes and suggests data on various high levels. The device that was used in the study measured fine dust concentration, humidity, temperature, atmospheric pressure, carbon dioxide, total volatile organic compounds (TVoc), and formaldehyde.

Monitoring of the Fugitive and Suspended Dust Dispersion at the Reclaimed Land and Neighboring Farms : Monitoring in Gunsan (간척지 인근 농경지에서의 비산 및 부유먼지 확산 모니터링(I) : 군산 모니터링)

  • Hwang, H.S.;Lee, I.B.;Shim, M.H.;Hong, S.W.;Seo, I.H.;Ryu, J.I.;Lee, S.K.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.4
    • /
    • pp.39-50
    • /
    • 2008
  • A study on fugitive dust dispersion was conducted at Saemanguem reclaimed area located at the west coastal area of Jeon-buk Province Total reclaimed area is 40,100ha developed by building a 33km long sea dike through Gunsan, Gimje, and Buan. (Land: 28,300ha, Fresh Water Lake: 11,800ha) After this area was completely reclaimed in 2006, there has been high possibility of dust generation and dispersion to the neighboring area. The dust generated at the reclaimed land was composed mainly of minerals with high salinity, and it could make harmful effect on crop production as well on to human's health such as eye irritation and respiratory disease. Especially, when those aerosol particles are reached on the leaves of farm crops, the photosynthesis and respiration of the plants can be under restraint resulting in the decrease of agricultural productivity of the nearby farm areas. Furthermore, highly concentrated salty particles can directly damage the leaf cells. In this study, field experiment has been conducted to regularly measure the locally suspended dust particles and analyze how they were dispersed to the neighboring areas. The collected dust particles were analyzed to examine theirs sizes, concentrations, and components. The SPSS statistical program was also used to separate the dust concentration generated by the reclaimed land from the total dust concentration measured at the measuring locations.

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.4
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

Concentration Rise of Fine Particle according to Resuspended Dust from Paved Roads after Sudden Heavy Rain in Busan (부산 도심지역 기습 폭우 후 형성된 도로면 토사의 재비산에 의한 미세먼지 농도 상승)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.25 no.5
    • /
    • pp.705-713
    • /
    • 2016
  • This study investigates the concentration sudden rise in fine particle according to resuspended dust from paved roads after sudden heavy rain in Busan on August 25, 2015. The localized torrential rainfall in Busan area occurred as tropical airmass flow from the south and polar airmass flow from north merged. Orographic effect of Mt. Geumjeong enforced rainfall and it amounted to maximum 80 mm/hr at Dongrae and Geumjeong region in Busan. This heavy rain induced flood and landslide in Busan and the nearby areas. The sudden heavy rain moved soil and gravel from mountainous region, which deposited on paved roads and near roadside. These matters on road suspended by an automobile transit, and increased fine particle concentration of air. In addition outdoor fine particle of high concentration flowed in indoor by shoes, cloths and air circulation.