• Title/Summary/Keyword: High $K^+$

Search Result 125,675, Processing Time 0.111 seconds

Study of high-energy cosmic rays by measuring coincidence events with plastic scintillation detector arrays at Kyeonggibuk Science High School and Hansung Science High School

  • Lim, Sun-In;Lee, Yu-Ni;Nam, Shin-Woo;Park, Il-Heung;Yang, Jong-Mann;Cho, Wo-Ram;Cho, Il-Sung;Kwon, Young-Joon;Bang, Hyung-Chan;Cheon, Byung-Gu;Park, So-Hee;Jung, Eu-Gene;Go, Yu-Kyung;Kim, Bok-Yung;Lee, Su-Yang;Sim, Hyoung-Jun;Hong, Kyung-Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.34 no.1
    • /
    • pp.188.2-188.2
    • /
    • 2009
  • PDF

Astronomy experiments using digital instruments (디지털 장비를 이용한 천문 실험)

  • Lee, Sang Hyun;Lee, Kyung Hoon;Lee, Enjung;Park, Joo Hyun;Jang, Kyu Bin;Lee, Dongho;Jo, Hyungyu;Lee, MinWook;Kim, Ga Hyung;Ku, Minjun;Seol, Jinwoo;Kim, Dong Ju;Kin, KangJin;Park, Gyutae;Kim, Do-Hoon;Kim, Do Yun;Lee, Sumin;Moon, SeongKeong;Shin, LaEl;Choi, Joonyoung;Ahn, Jaehyung;Choi, Wonseok;Kim, ChiYoung;Park, Jeong Hyeon;Jo, Se Hyeun;Shin, Kwan Hun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.63.4-64
    • /
    • 2016
  • 본 발표에서는 DSLR 카메라와 CCD를 이용하여 과학고등학교의 R&E교육과정에서 수행한 몇 가지 실험과 그 결과를 소개한다. DSLR 카메라와 SQM을 이용한 밤하늘 특성 분석, CCD를 이용한 고유운동 측정, DSLR을 이용한 산개성단의 측광, CCD를 이용한 산개성단의 측광과 이를 통한 산개성단의 질량분리와 역학적 진화에 대한 연구이다. 실험은 부산일과학고, 울산과학고, 부산과학고에서 수행되었으며, 모든 실험의 결과는 학생들이 직접 관측한 결과를 바탕으로 이루어졌다. 본 실험의 방법과 과정은 일선 학교에서 응용하여 활용될 수 있으며, 실험의 결과는 향후 유사한 실험 교육을 수행할 때 기초 자료로 활용되어 질 수 있다.

  • PDF

Fabrication and Evaluation of AC 400 kV High Voltage Divider using Electric Field Sensor (전기장 센서를 이용한 교류 400 kV 고전압 분압기의 제작 및 평가)

  • Lee, Sang-Hwa;Han, Sang-Gil;Jung, Jae-Kap;Kang, Jeon-Hong;Kim, Yoon-Hyoung;Jeong, Jin-Hye;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.265-269
    • /
    • 2008
  • Output voltage value of AC high voltage source has usually been obtained by measuring the low arm voltage of high voltage divider or the secondary voltage of high voltage transformer. In this study, we have fabricated the AC 400 kV high voltage divider using high voltage electrode and electric field measurement sensor. The dividing ratio of the fabricated 400 kV high voltage divider was evaluated using reference 400 kV capacitive divider. The dividing ratio of 400 kV high voltage divider is found to be 12,322 and has the good linearity within 0.63 % against AC high voltage up to 400 kV. Therefore, the developed 400 kV high voltage divider could evaluate 400 kV high voltage supply and voltage divider used in industry.

High Speed and Sensitive X-ray Analysis System with Automated Aberration Correction Scanning Transmission Electron Microscope

  • Inada, Hiromi;Hirayama, Yoichi;Tamura, Keiji;Terauchi, Daisuke;Namekawa, Ryoji;Shichiji, Takeharu;Sato, Takahiro;Suzuki, Yuya;Ohtsu, Yoshihiro;Watanabe, Keitaro;Konno, Mitsuru;Tanaka, Hiroyuki;Saito, Koichiro;Shimoyama, Wataru;Nakamura, Kuniyasu;Kaji, Kazutoshi;Hashimoto, Takahito
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • We have developed a new HD-2700 (Hitachi High-Technologies Corp., Japan) scanning transmission electron microscope (STEM) that includes an automatic aberration correction function, and a large-solid-angle energy-dispersive X-ray spectroscopy detector that enables high-resolution and sensitive analysis. For observation with atomic resolution, using spherical-aberration-corrected STEM, in order that satisfactory performance of the device can be achieved readily, and within a short time, irrespective of the operator's skill level, a spherical-aberration-correction device with an automatic aberration-correction function was developed. This automatic aberration-correction function carries out the entire correction-related process (aberration measurement, selection and correction) automatically, with automatic selection of the aberrations that require correction, and automatic measurement of the appropriate corrections.

High voltage pulse power supply using thyratron (Thyratron을 이용한 고압펄스 발생장치)

  • Kim, T.J.;Kim, S.C.;Kim, E.S.;Baek, J.W.;Pavlov, E.P.;Lee, H.S.;Jeon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2127-2129
    • /
    • 1998
  • In this paper, discharging part of high voltage pulse power supply of E-beam generating device is simulated and experimented. It is composed of high voltage part and high voltage pulse part. High voltage part is AC 380, DC/DC converter, high voltage high frequency transformer. High voltage pulse part is double pulse forming network and Thyratron. In the result, computer simulation analysis is same to experimental result and high voltage pulse is obtained 10kV, 4A, 10uS.

  • PDF

Warpage of Co-fired High K/Low K LTCC Substrate (고유전율/저유전율 LTCC 동시소성 기판의 휨 현상)

  • Cho, Hyun-Min;Kim, Hyeong-Joon;Lee, Chung-Seok;Bang, Kyu-Seok;Kang, Nam-Kee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.77-82
    • /
    • 2004
  • In this paper, warpages of heterogeneous LTCC substrates comprised of high K/low K hi-layered structure were investigated. The effect of glass content in high K LTCC layer on the warpage of substrate during co-firing process was examined. Shrinkage and dielectric properties of high K and low K green sheets were measured. In-situ camber observation by hot stage microscopy showed different camber development of heterogeneous LTCC substrates according to glass content in high K green sheet. High K green sheet containing $50\%$ glass was matched to low K green sheet in the shrinkage. Therefore, LTCC substrate of Low K/High K+$50\%$ glass structure showed flat surface after sintering.

  • PDF

A Basic Data Research on Advantage Studying of Junior College for Graduation Students of Technical High School in Department of Electricity (공업고등학교 전기관련과의 수학교육 보완에 관한 연구)

  • Lee, Sang-Seock;Shin, Yong-Cheol;Kim, Min-Huei;Park, Chan-Gyu;Lee, Jae-Yong;Cho, Sea-Ho;Song, Tae-Beom;Bae, Byung-Ho;Lee, Jong-Woo;Jeong, Ahn-Sik;Choi, Sung-Ha;Shin, Dong-Soo;Yoon, Sang-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.3-9
    • /
    • 2004
  • This research is that concern in mathematics education of Technical high school Department of Electricity in the 7th educational curriculum. Indicated problem of mathematics education of Technical high school Department of Electricity at 7th educational curriculum as that compare mathematics subject contents with difference of Technical high school mathematics education in the 6th and the 7th educational curriculum. And examine major subject contents, analyzed contents of mathematics that must supplement and mathematics which use in major subject. Established contents of electricity mathematics education that need to major learning to satisfy target of technical high school technical education that is presented in the 7th training courses with this analysis

  • PDF

Study of High-k Sensing Membranes for the High Quality Electrolyte Insulator Semiconductor pH Sensor (High-k 감지막 평가를 통한 고성능 고감도의 Electrolyte-Insulator-Semiconductor pH센서 제작)

  • Bae, Tae-Eon;Jang, Hyun-June;Cho, Won-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.125-128
    • /
    • 2012
  • We fabricated the electrolyte-insulator-semiconductor (EIS) devices with various high-k sensing membranes to realize a high quality pH sensor. The sensing properties of each high-k dielectric material were compared with those of conventional $SiO_2$ (O) and $SiO_2/Si_3N_4$ (ON) membranes. As a result, the high-k sensing membranes demonstrated better sensitivity and stability than the O and ON membranes. Especially, the $SiO_2/HfO_2$ (OH) stacked layer showed a high sensitivity and the $SiO_2/Al_2O_3$ (OA) stacked layer exhibited an excellent chemical stability. In conclusion, the high-k sensing membranes are expected to have excellent operating characteristics in terms of sensitivity and chemical stability for the biosensor application.

Recent development of high gradient superconducting magnetic separator for kaolin in china

  • Zhu, Zian;Wang, Meifen;Ning, Feipeng;Yang, Huan;Li, Peiyong;Zhang, Yiting;Wang, Zhaolian;Zhang, Guoqing;Hou, Zhilong;Liu, Zhongxiu;Dai, Zhong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.5-8
    • /
    • 2017
  • A series of high gradient superconducting magnetic separator (HGMS) for kaolin has been developed. It is used for processing kaolin to increase the brightness or whiteness whether it is for paper or ceramic applications. The HGMS system mainly consists of a solenoid magnet with a zero boil-off helium cryostat, a double reciprocating canisters system, and a PLC (Process Logic Controller) fully automatic control system based on SCADA (Supervisory Control and Data Acquisition) system. We have successfully developed CGC-5.5/300 and CGC-5.0/500 HGMS systems in the recent years, and now three sets of them are on-site operation in different customers. This paper will present recent progress of the HGMS system, the results of some experiments on processing kaolin clay used HGMS, and the on-site operation.