• 제목/요약/키워드: HgS

검색결과 1,000건 처리시간 0.027초

A Carbazole-Attached NO2S2-Macrocycle Exhibiting Hg2+ and Cu2+ Selectivity

  • Lee, Seul-Gi;Kang, Eun-Ju;Lee, Shim Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권5호
    • /
    • pp.1429-1434
    • /
    • 2013
  • A synthesis and cation-induced fluorescent behavior of the carbazole-attached $NO_2S_2$-macrocycle (L) is described and structurally characterized by single crystal X-ray analysis. The photoluminescence spectrum of L in 80% $CH_3CN/CH_2Cl_2$ displays a peak maximum at 431 nm (blue emission). In the metal-induced fluorometric experiment, L showed a drastic chelation-enhanced fluorescence quenching (CHEQ) effect only with $Hg^{2+}$ and $Cu^{2+}$. In ESI-mass study, a 1:1 stoichiometry for complexation of L with $Hg^{2+}$ was confirmed, suggesting the unique sensing behavior of the proposed ligand L due to the selective complexation affinity for $Hg^{2+}$. The observed results indicate that L is a promising turn-off type fluoroionophore for $Hg^{2+}$ and $Cu^{2+}$ detections. Additionally, the $Ag^+$ complex of the precursor macrocycle was prepared and its solid structure was crystallographically characterized.

Taxus chinensis로부터 파클리탁셀 정제를 위한 음압 캐비테이션 아세톤-펜테인 분별침전 (Negative Pressure Cavitation Acetone-Pentane Fractional Precipitation for the Purification of Paclitaxel from Taxus chinensis)

  • 민혜수;김진현
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.544-549
    • /
    • 2022
  • 본 연구에서는 음압 캐비테이션 아세톤-펜테인 분별침전으로 Taxus chinensis로부터 파클리탁셀의 침전 효율을 획기적으로 개선하였다. 음압 -200 mmHg에서 침전할 경우 짧은 조업 시간(5분)에 대부분의 파클리탁셀을 회수(>99.9%) 할 수 있었다. 침전 속도 상수는 대조군 대비 1.512~5.073배(-50~-200 mmHg) 증가하였다. 음압으로 활성화에너지는 -3737~-6536 J/mol 감소하였으며, 이로 인해 침전 속도가 증가하였다. 또한 음압 도입으로 침전물 크기는 5.3배 감소하였으며, 파클리탁셀의 확산 계수는 7.0배 증가하였다.

HgTe/Cdte superlattices grown on CdZnTe(211)B by MBE

  • Kang, T.W.;Jeong, C.S.;Leem, J.H.;Ryu, Y.S.;Hyun, J.K.;Jeon, H.C.;Lee, H.Y.;Han, M.S.
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.34-42
    • /
    • 1997
  • Hg-Te-CdTe superlattices have received much interests over the last several years as a potential material for its applications for detecting devices and optoelectronics. We have grown the HgTe-CdTe superlattice using MBE. in our lab. We have carried out DCRC spectroscopy after growth of HgTe-CdTe superlattice with varying the superlattice periods and controlling the barrier thickness and we have that the presence of the main peak and the satellite peaks. We obtained 20 arcsec of FWHM over 100 periods of superlattice. We also note that high peak intensity shows the high quality of the sample and each layer of superlattice has abrupt interfaces. The angular separation between the main peak(m=0) and the first satellite peak(m=$\pm$1) is increased when the barrier layer thickness in superlatice layers are decreased. The separation between the first setellite peak(m=$\pm$1) and the second satellite peak(m$\pm$2) is increased similarly. The number of the satellite peak is a qualitative measure of the interfacial abruptness of the superlattice.

  • PDF

앉은 자세에서 좌골결절의 접촉압력과 혈류량과의 관계에 대한 연구 (Study on the Relationship between Vascular Perfusion and Interface Pressure under the Ischial Tuberosity in the Sitting Posture)

  • 허현;배태수;이석민;김신기;김경훈;문무성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.645-646
    • /
    • 2006
  • Pressure-induced decubitus is a serious disease among the elderly people. Interface pressure occluding vascular perfusion is known to be a cause of decubitus. Therefore, it is essential to quantify the relationship between vascular perfusion and interface pressure among the elderly people. Nine elderly normal people ($57.8{\pm}5.6\;years,\;63.3{\pm}7.0kg,\;1.68{\pm}0.05m$) were participated. Pressure was applied on the ischial tuberosity in the sitting posture from 0mmHg to 135mmHg as capillary vascular perfusion was recorded. The average interface pressure to occlude vascular perfusion under the ischial tuberosity is 120mmHg. Vascular perfusion values at the capillary occlusion is often lower than 60% of the vascular perfusion at 15mmHg. Higher sampling number is required to have more accurate results.

  • PDF

한국산 큰가시고기와 어류의 지리적 변이 및 계통적 유연관계 (Genetic Vadation and Systematics of the Sticklebacks (Pisces, Gasterosteidae) in Korea)

  • 양서영;민미숙
    • 한국동물학회지
    • /
    • 제33권4호
    • /
    • pp.499-508
    • /
    • 1990
  • 한반도 연안과 담수역에 서식하는 큰가시고기과(Gasterosteidae) 어류인 Gasterosteus속 G.aculeatus와 Pungitius 속 P. sinensis,P. kaibarae에 대한 유전자 분석을 통하여 이들의 계통적 유연관계를 조사하였다. P. sinensis 5개 집단의 평균 유전적 변이 정도는 HD = 0.080, HG = 0.091, P = 29%로 P.kaibarae (HD = 0.034; HG = 0.034, P = 13%)보다 높았으며 G.aculeatus의 평균 유전적 변이는 HD = 0.086, HG = 0.084, P =36%였다. G.aculeatus의 집단간 평균 유전적 근연치는 S = 0.963으로 가깝게 나타났으며 Pungitius 속 P. sinensis역시 S = 0.953으로 종내 집단간 차이가 크지 않았다. P. kaibarae의 경우 영천집단과 경주집단은 나머지 4집단과는 형태적으로 뚜렷한 차이가 있고,(Chae,1998) 유전적 근연치도 S=0.690으로 현저한 차이가 있어 별개의 taxa로 사료된다. P. sinensis 와 P. kaibarae 사이의 유전적 근연치는 S=0.606으로 종간 차이치를 나타내었으나 이들의 공서지역인 강릉집단에서는 약 44% 정도의 잡종개체가 발견되는 것으로 보아 이들간에는 생식적 격리가 완전히 형성되지 않은 반종으로 사료된다. Pungitius속과 Gasterosteus속간 유전적 근연치는 S=0.052로서 타어류의 속간 근연치보다 현저히 낮았다.

  • PDF

정상인의 요중 수은배설량 추정의 통계학적 연구 (Some Statistical Considerations for the Estimation of Urinary Mercury Excretion in Normal Individuals)

  • 박희숙;정규철
    • Journal of Preventive Medicine and Public Health
    • /
    • 제13권1호
    • /
    • pp.27-34
    • /
    • 1980
  • Purpose of this study is to find out proper means of estimating the urinary mercury excretion in the normal individuals. Whole void volume was collected every 2 hours beginning from 6 o'clock in the morning until 6 o'clock next morning. Mercury excretion in each urine specimen was measured by NIOSH recommended dithizone colorimetric method (Method No.: P & CAM 145). Urinary concentration of mercury was adjusted by two means: specific gravity of 1.024 and a gram of creatinine excretion per liter of urine comparing the data with the unadjusted ones. Mercury excretion in 24-hour urine specimen was calculated by adding the amounts measured with the hourly collected specimens of each individual. Statistical analysis of the urinary mercury excretion revealed the following results: 1. Frequency distribution curve of mercury excreted in urine of hourly specimens was best fitted to power function expressed in the form of $y=ax^b$. Adjustment of the urinary mercury concentration by creatinine excretion was shown to be superior($y=1674x^{-1.52},\;r^2=0.95$) over nonadjustment($y=2702x^{-1.57},\;r^2=0.92$) and adjustment by specific gravity of 1.024($y=4535x^{-1.66},\;r^2=0.93$). 2. Both log-transformed mercury excretion in hourly voided specimens and mercury excretion itself in 24 hour specimens showed the normal distributions. 3. The frequency distribution of mercury adjusting the urinary concentration of mercury by creatinine excretion was best fitted to a theoretical normal distribution with the sample means and standard deviation than those unadjusted or adjusted with specific gravity of 1.024. 4. Average urinary mercury excretions in 24-hour urine specimen in an individual were as follows: a) Unadjusted mercury excretion mean and standard deviation : $$18.6{\pm}13.68{\mu}gHg/l$$. median : $$16.0\;{\mu}gHg/l$$. range : $$0.0-55.10\;{\mu}gHg/l$$. b) Adjusted with specific gravity mean : $$20.7{\pm}11.76\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ median : $$20.7\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ range : $$0.0-52.9\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ c) Adjusted with creatinine excretion mean and standard deviation : $$10.5{\pm}6.98\;{\mu}gHg/g$$ creatinine/l median : $$9.4\;{\mu}gHg/g$$ creatinine/l range : $$0.0-26.7\;{\mu}gHg/g$$ creatinine/l 5. No statistically significant differences were found between means calculated from 24-hour urine specimens and those from hourly specimens transformed into logarithmic values. (P<0.05).

  • PDF

Sarns 심폐기의 혈희석 체외순환에 관한 실험적 연구 (Experimental Studies on Extracorporeal Circulation by Sarns Heart-Lung Machine with Total Prime of Hartman's Solution)

  • 김근호
    • Journal of Chest Surgery
    • /
    • 제8권2호
    • /
    • pp.135-142
    • /
    • 1975
  • Total body perfusion using Sarns Heart-Lung-Machine, five head pump motor system with Travenol disposable bubble oxygenator was attempted in the dogs by the hemodilution method with total prime of buffered Hartman`s solution under moderate hypothermia. The first of all, the functions of Sarns Heart-Lung-Machine and effects of the hemodilution perfusion by buffered Hartman`s solution was studied. At the same time the changes of pressure of artery and vein, gas contents of the blood, and influence on the blood pictures were observed before, during, and after perfusion in 1-2 days. Hemodilution rates were the ranges of 85.0ml/kg to 97.3ml/kg and perfusion flow rates were maintained with the average 80. 5ml/kg/min [the ranges of 73.3ml/kg/min to 92.8ml/kg/min]. Hypothermia was employed between $35^{\circ}C$ and $31^{\circ} of the esophageal temperature. The total body perfusion was continued for 50-60 minutes. In the total cardiopulmonary bypass, atriotomy, ventriculotomy, and atrioventriculotomy were performed respectively. Arterial pressure was ranged approximately between 50 mmHg and 140 mmHg, but generally, it was maintained over 75 mmHg. Venous pressure was measured between 3.8 cm$H_2O$ and 16.0 cm$H_2O$. Optimum oxygenation could be achieved when oxygen flow into the oxygenator was maintained approximately at 5. 5L/min. In this way, the $pO_2$, $pCO_2$, and oxygen saturation were measured before, during, and afterperfusion in 1-2 days. The $pCO_2$ ranged approximately between 26.0 mmHg and 38.5 mmHg, but generally, it was maintained in the average 30.9-32.5mmHg. The $pO_2$ was ranged between 73.0mmHg and 332.2 mmHg, but it was maintained in the average 103.0-219.0 mmHg. Oxygen saturation was measured over 95. 0% during and after extracorporeal circulation respectively. Erythrocyte count, hemoglobin, hematocrit, and leucocyte count were decreased to 49.2%, 49.0%, 49.4%, and 21. 1% of the preoperative value during extracorporeal circulation respectively and these reductions were not recovered until 1-2 days after perfusion. These. resulted from relatively high degree of hemodilution rate and operative bleeding during these experimental studies. The platelets count was also decreased about to 71% during perfusion, on the contrary, it was increased progressively after perfusion and in 1-21 days after perfusion, the value was returned to preoperative contro1 level. Three dogs were all recovered after extracorporeal circulation.

  • PDF

서울지역 거주 성인 모발의 유해 중금속 함량 분석 (Heavy Metal Analysis of Inhabitants from City of the Seoul, Korea)

  • 임은진;하병조
    • 대한화장품학회지
    • /
    • 제35권1호
    • /
    • pp.27-32
    • /
    • 2009
  • 인간의 모발은 금속을 배설하는 시스템이며 몸에서 금속의 함유량을 반영한다. 본 연구에서는 현대인의 유해 중금속 노출 정도를 파악하고, 질병 예방 혹은 환경 개선 예측의 도구로서 모발 분석의 필요성에 대해 알아보고자 하였다. 많은 만성 질환은 금속의 축척과 관련이 있을 것으로 예상되며 몇몇은 유해 중금속과 관련이 있다. 이에 서울, 수도권지역에 거주하는 20대에서 40대의 성인 남녀 120명(남자 61명, 여자 59명)을 대상으로 시료를 채취한 후 유도 결합 플라즈마 질량 분석기를 사용하여 Hg, Pb, Cd, Al, As, U, Bi, Sb, Ba, Be의 10가지의 독성 미네랄의 함량을 측정하였다. 분석 결과 20대의 유해 중금속 함량 분석에서는 기준치 이상을 보이는 원소가 없었으나, 알루미늄(Al)과 안티몬(Sb)의 수치가 높게 나타났다. 30대의 경우도 기준치 이상의 원소는 보이지 않았으나 수은(Hg)과 알루미늄(Al)의 농도가 높게 나타났다. 40대의 경우 기준치 이상의 수은(Hg)과 안티몬(Sb)이 검출되었다. 또한 성별에서는 남성의 경우 수은(Hg)이, 여성의 경우 안티몬(Sb)이 기준치보다 높은 것으로 나타났다. 산업의 발달로 인해 유해 중금속은 여러 가지 경로를 통해 우리 몸속으로 들어오며, 몸 밖으로 배출되지 못하고 인체에 계속 쌓여 면역 기능과 호르몬 기능이 저하시키고 질병을 유발하게 된다. 이에 유해 중금속의 노출 정도를 분석하여 그에 맞는 대체요법을 시행한다면 질병을 예방하고 환경을 예측할 수 있다. 인체 내에 중금속의 추적 상태를 알아보기 위해 우리나라에서도 모발 분석에 대한 관심과 연구를 통해 우리의 건강 상태를 유지하기 위한 수단으로 활용되기를 시사하는 바이다.

HgCdTe MIS의 이중 절연막 특성에 관한 연구 (A study on the characteristics of double insulating layer)

  • 정진원
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권5호
    • /
    • pp.463-469
    • /
    • 1996
  • The double insulating layer consisting of anodic oxide and ZnS was formed for HgCdTe metal insulator semiconductor(MIS) structure. ZnS was evaporated on the anodic oxide grown in H$_{2}$O$_{2}$ electrolyte. Recently, this insulating mechanism for HgCdTe MIS has been deeply studied for improving HgCdTe surface passivation. It was found through TEM observation that an interface layer is formed between ZnS and anodic oxide layers for the first time in the study of this area. EDS analysis of chemical compositions using by electron beam of 20.angs. in diameter and XPS depth composition profile indicated strongly that the new interface is composed of ZnO. Also TEM high resolution image showed that the structure of oxide layer has been changed from the amorphous state to the microsrystalline structure of 100.angs. in diameter after the evaporation of ZnS. The double insulating layer with the resistivity of 10$^{10}$ .ohm.cm was estimated to be proper insulating layer of HgCdTe MIS device. The optical reflectance of about 7% in the region of 5.mu.m showed anti-reflection effect of the insulating layer. The measured C-V curve showed the large shoft of flat band voltage due to the high density of fixed oxide charges about 1.2*10$^{12}$ /cm$^{2}$. The oxygen vacancies and possible cationic state of Zn in the anodic oxide layer are estimated to cause this high density of fixed oxide charges.

  • PDF

HgCdTe를 이용한 Infrared Detector의 제조와 특성 (Fabrication and Its Characteristics of HgCdTe Infrared Detector)

  • 김재묵;서상희;이희철;한석룡
    • 한국군사과학기술학회지
    • /
    • 제1권1호
    • /
    • pp.227-237
    • /
    • 1998
  • HgCdTe Is the most versatile material for the developing infrared devices. Not like III-V compound semiconductors or silicon-based photo-detecting materials, HgCdTe has unique characteristics such as adjustable bandgap, very high electron mobility, and large difference between electron and hole mobilities. Many research groups have been interested in this material since early 70's, but mainly due to its thermodynamic difficulties for preparing materials, no single growth technique is appreciated as a standard growth technique in this research field. Solid state recrystallization(SSR), travelling heater method(THM), and Bridgman growth are major techniques used to grow bulk HgCdTe material. Materials with high quality and purity can be grown using these bulk growth techniques, however, due to the large separation between solidus and liquidus line on the phase diagram, it is very difficult to grow large materials with minimun defects. Various epitaxial growth techniques were adopted to get large area HgCdTe and among them liquid phase epitaxy(LPE), metal organic chemical vapor deposition(MOCVD), and molecular beam epitaxy(MBE) are most frequently used techniques. There are also various types of photo-detectors utilizing HgCdTe materials, and photovoltaic and photoconductive devices are most interested types of detectors up to these days. For the larger may detectors, photovoltaic devices have some advantages over power-requiring photoconductive devices. In this paper we reported the main results on the HgCdTe growing and characterization including LPE and MOCVD, device fabrication and its characteristics such as single element and linear array($8{\times}1$ PC, $128{\times}1$ PV and 4120{\times}1$ PC). Also we included the results of the dewar manufacturing, assembling, and optical and environmental test of the detectors.

  • PDF