• 제목/요약/키워드: Hg(II)

검색결과 311건 처리시간 0.036초

금속이온흡착 특성에 미치는 키토산 섬유 굵기의 영향 (Effects of Fineness of Chitosan Fiber on the Adsorption Characteristics of Metal Ion)

  • 최해욱;정영진;이명환;이순장;박수영;이신희
    • 한국염색가공학회지
    • /
    • 제15권3호
    • /
    • pp.146-153
    • /
    • 2003
  • This article describes the metal ions adsorption of chitosan fibers. The chitosan fibers were manufactured by wet spinning using 2% acetic acid as solvent, 10% aqueous sodium hydroxide as non solvent, and 4%chitosan solution as a solvent. The adsorption characteristics of chitosan fibers towards 100ppm solutions of various metal ions such as Cu(II), Cd(II), Cr(III), Hg(II) were examined at different pH value by ICP-Atomic Emission Spectrometer. The adhesiveness of metallic ions to the chitosan fiber were increased with the increase of pH and the decrease of denier. On the other hand, from pH4, chitosan fiber that is immersed in metal ion aqueous solution of Cu(II) and Cd(II) became homogeneous solution because is dissolved. The adhesiveness of metallic ions to chitosan fiber were found to increased in a sequence of Hg(II)> Cr(III)> Cu(II)> Cd(II). The antimicrobial characteristics of the chitosan fiber by adhered metal ions, virgin chitosan fiber, and cotton fiber were evaluated. The antimicrobial activity of the fibers were increased with the decrease of denier.

한약재와 탕액(십전대보탕) 중 내분비계 장애물질로서의 개별 중금속 함량분석(II) (Monitoring Research for Heavy Metals as Endocrine Disruptors in Sibjeonaebotang and Its Ingredients Herbal Medicines(II))

  • 김진숙;황성원;김종문;마진열
    • 약학회지
    • /
    • 제45권5호
    • /
    • pp.448-454
    • /
    • 2001
  • The contents of heavy metals in boiled Sibjeonaebotang with those in its herbal ingredients are compared. The herbal medicines of Sibjeonaebotang were bought at 10 defferent markets. The contents of 14 heavy metals (Ag, As, Ba, Cd, Cr Cu, Fe, Hg, Mn, Ni, Pb, Sb, Sn, Zn) were analysed using ICP It was found out that 5 heavy metals (Pb, As, Ba, Fe, Sb) were detected in only one boiled Sibjeonaebotang But they were detectable in all Sibjeonaebotang and its herbal before boiling. For example the content of Hg in one pack of Sibjeonaebotang before boiling was 0.064$\pm$0.016 me and Hg in boiled one was 0.002$\pm$0.005mg. These results suggest that boiled Sibjeonaebotang which we take is less harmful than herbal medicine itself by heavy metals.

  • PDF

거대고리 운반체에 의한 중금속이온의 에멀죤 액체막 수송 (Emulsion Liquid Membrane Transport of Heavy Metal Sons by Macrocyclic Carriers)

  • 정오진
    • 한국환경과학회지
    • /
    • 제4권2호
    • /
    • pp.223-232
    • /
    • 1995
  • 액체막의 운반체로 사용할 새로운 2개의 거대고리화합물을 합성하였다. 이들 결과들은 이 시스템을 구성하는데 있어서 이론의 응용성을 증명하여 준다. source phase의 공존이온으로서 $SCN^-$,$I^-$$Cl^-$이온을 그리고 receicing phases에서 $S_2O_3^{2-}$$P_2O_7^{4-}$을 이용한 액세막계로서부터 중금속 이온들에 대한 선택적 수송효율을 검토하였다. source phase의 M(II)이 $Cd(SCN)_2$$(P[SCN^-]= 0.40M)$, $Hg(SCN)_2([SCN^-]=0.40M)$, Pd(CN)$([CN^-]= 0.40M)$일때 M(II)의 수송율은 최대값을 나타낸다. 각가의 경쟁 양이온에 대한 Cd(II)이나 Pd(II)은 source phase가 00.3M-$S_2O_3^{2-}$이나 0.3M-$P_2O_7^{4-}$ 일때 가장 잘 분리된다.이 연구의 결과에서, 이 액체막계에서 효과적인 거대고리-매질수송을 하기 위해서는 두개의 규칙이 반드시 필요하다. 첫째, tiluence중으로 $M^{n+}$이온이 효과적으로 추출되고, 즉 만일 $M^{n+}$ 거대고리화합물 상호작용에 대한 logK값과 $M^{n+}$-거대고리화합물($L_1$이나 $L_2$)의 상호작용에 대한 logK값의 비가 충분히 크다면 receiving phase와 toluene의 접촉면으로부터 쉽게 중금속이온($Cd^{2+}$,$Pb^{2+}$$Hg^{2+}$)들이 떨어져 나온다. $L_1$(3,5-benzo-10,13,18,21-tetraoxa-1,7-diazabicyclo(8,5,5)eicosnan)은 $Cd^{2+}$$Pb^{2+}$ 이온과 안정한 착물을 형성한다. 그리고 $L_1$은 수용액중에서 용해하기가 매우 어렵다. 그리고 $Cd^{2+}$$L_1$$Pb^{2+}$$L_1$착물은 $Cd^{2+}-{(S_2O_3)}_2^{2-}$$Pd^{2+}-P_2O_7^{4-}$착물보다 비교적 불안정하다. 다른 한편으로 $Hg^{2+}-L_1$착물의 안정도는 $Hg^2-{2+}-(S_2O_3)_2^{2-}$이나 $Pb^{2+}-P0_2O_7^{4-}$의 그것보다 그리고 $L_2$(5,8,15,18,23,26-hexaoxa-1,12-diazabicyclo(10,8,8)octacosan)의 tuluene에 대한 분배계수는 $L_1$의 그것보다 훨씬 작다. 따라서 $Hg^{2+}$-$L_1$이나 $M^{n+}$이나 $M^{n+}-L-2(M^{2+}=Cd^{2+}, Pb^{2+}$이나 $Hg^{2+})$의 안정도수상수가 매우 큼에도 불구하고 이들 양이온의 수송량은 매우 적다.

  • PDF

Analysis of Heavy Metal Toxic Ions by Adsorption onto Amino-functionalized Ordered Mesoporous Silica

  • Showkat, Ali Md;Zhang, Yu-Ping;Kim, Min-Seok;Gopalan, Anantha Iyengar;Reddy, Kakarla Raghava;Lee, Kwang-Pill
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권11호
    • /
    • pp.1985-1992
    • /
    • 2007
  • Ordered mesoporous silica (MCM-41) materials with different textural properties were prepared using alkyl (dodecyl, cetyl, eicosane) trimethyl ammonium bromide (DTAB, CTAB, ETAB, respectively) as structure directing surfactants, functionalized with amine groups and used as adsorbent for the toxic metal ions, Cr (VI), As (V), Pb (II) and Hg (II). Amino functionalization of mesoporous MCM-41 was achieved by cocondensation of N-[3-(trimethoxysilyl)-propyl] aniline with tetraethyl orthosilicate. Adsorption isotherm and adsorption capacity of the amine functionalized materials for Cr (VI), As (V), Pb (II) and Hg (II) ions were followed by inductively coupled plasma mass spectrometry (ICP-MS). Results demonstrate that amine functionalized MCM-41 prepared with ETAB showed higher adsorption capacity for Cr (VI), As (V), Pb (II) and Hg (II) ions in comparison to MCM-41 prepared with CTAB and DTAB. The higher adsorption capacity for MCM-41(ETAB) was correlated with amine content in the material (determined by CHN analysis) and relative decrease in pore volume and pore diameter. X-ray diffraction (XRD) analysis, nitrogen adsorptiondesorption measurements and Fourier Transform infrared spectrometry (FTIR) were used to follow the changes in the textural parameters and surface properties of the mesoporous materials as a result of amine functionalization to correlate with the adsorption characteristics. The adsorption process was found to depend on the pH of the medium.

肺의 低溫保存法이 肺機能 回復에 미치는 영향 (Effect of Recovery of Pulmonary Function in Hypothermic Lung Preservation)

  • 이만복;김우종;강창희;이길노
    • Journal of Chest Surgery
    • /
    • 제30권3호
    • /
    • pp.253-253
    • /
    • 1997
  • 가토의 적출폐장보고시험의 모델을 이용하여 폐세척웅액과 폐장보존용액의 온도를 제 1군은 4℃로 제 2군은 10℃로 하여 6시간동안 적출폐장보존후에 재관류시켜 각각의 온도차이에 따른 폐기보존효과를 비교 실험하였으며 각 군은 10례씩으로 하였다. 폐정맥혈액산소분압, 폐포-동맥간 산소분압 차, 폐동 맥압 및 폐혈관저항은제 1군보다제 2군이 재관류동안에 성적이 우수하였으며 기도내압, 폐탄성도및 폐부종의 정도는 두 군간에 통계학적 유의성은 없었다. 결론적으로 가토의 적출폐기 보존온도에 따른 실험에서 10℃의 폐수*용액과 폐기보존온도가 4℃보다 재순환시 폐기능의 회복이 우수하였다.

Selective Trace Analysis of Mercury (II) Ions in Aqueous Media Using SERS-Based Aptamer Sensor

  • Lee, Chank-Il;Choo, Jae-Bum
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2003-2007
    • /
    • 2011
  • We report a highly sensitive surface-enhanced Raman scattering (SERS) platform for the selective trace analysis of mercury (II) ions in drinkable water using aptamer-conjugated silver nanoparticles. Here, an aptamer designed to specifically bind to $Hg^{2+}$ ions in aqueous solution was labelled with a TAMRA moiety at the 5' end and used as a Raman reporter. Polyamine spermine tetrahydrochloride (spermine) was used to promote surface adsorption of the aptamer probes onto the silver nanoparticles. When $Hg^{2+}$ ions are added to the system, binding of $Hg^{2+}$ with T-T pairs results in a conformational rearrangement of the aptamer to form a hairpin structure. As a result of the reduced of electrostatic repulsion between silver nanoparticles, aggregation of silver nanoparticles occurs, and the SERS signal is significantly increased upon the addition of $Hg^{2+}$ ions. Under optimized assay conditions, the concentration limit of detection was estimated to be 5 nM, and this satisfies a limit of detection below the EPA defined limit of 10 nM in drinkable water.

${Hg}_{1-x}{Cd}_{x}$Te MIS 소자의 C-V 특성 계산 (A Calculation of C-V Characteristics for ${Hg}_{1-x}{Cd}_{x}$Te MIS Device)

  • 이상돈;김봉흡;강형부
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.420-431
    • /
    • 1994
  • The HgCdTe material, which is II-VI compound semiconductor, is important materials for the fabrication of the infrared detectros. To suggest the model of accurate MIS C-V calculation for narrow band gap semiconductors such as HgCdTe, non-parabolicity from k.p theory and degeneracy effect are considered. And partially ionized effect and compensation effect which are material's properties are also considerd. Especially, degenerated material C-V characteristics from Fermi-Dirac statistics and exact charge theory are presented to get more accurate analysis of the experimental results. Also the comparison with calculation results between the general MIS theory from Boltzmann appoximation method and this model which is considered the narrow band gap semiconductor properties, show that this model is more useful theory to determination of accurate low and high frequency C-V characteristics.

  • PDF

Rhodamine Based Fluorescent Chemosensors for Hg2+ and its Biological Application

  • Choi, Ji-Young;Kim, Wan-Tae;Yoon, Ju-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2359-2364
    • /
    • 2012
  • Two new chemosensors, rhodamine 6G derivative bearing hydroxyethyl group (1) and rhodamine base derivative bearing 15-crown-5 group (2) were synthesized and their sensing behaviors toward various metal ions were investigated by UV/Vis and fluorescence spectroscopies. Addition of $Hg^{2+}$ ion to a $CH_3CN$ solution of 1 and 2 gave visual color changes as well as fluorescent OFF-ON observations. Selectivity and sensitivity of 1 towards $Hg^{2+}$ are excellent enough to detect micromolar level of $Hg^{2+}$ ion, even in equeous media and biological sample (HeLa cell).

Cucumber (Cucumis sativus L.) Fruit and Combination with Losartan Attenuate the Elevation of Blood Pressure in Hypertensive Rats Induced by Angiotensin II

  • Tomi Hendrayana;Klaudia Yoana;I Ketut Adnyana;Elin Yulinah Sukandar
    • 대한약침학회지
    • /
    • 제26권4호
    • /
    • pp.298-306
    • /
    • 2023
  • Objectives: Cucumis sativus L. (C. sativus) is vegetable commonly used for managing blood pressure and often consumed in combination with standard antihypertensive therapy, despite lack of scientific evidence supporting their use. Combination of herbs and standard medication could have positive or negative effects. Therefore, this study aimed to evaluate the antihypertensive activity of C. sativus and the combined effect with losartan in the hypertensive rat model induced by angiotensin II. Angiotensin II is a component of the renin-angiotensin-aldosterone system that, upon binding to its receptor, constricts blood vessels leading to elevation of blood pressure. Methods: In an antihypertensive study, rats received C. sativus orally at doses of 9, 18, 27, and 36 mg/kg (full dose); while in a combination study, animals received losartan 2.25 mg/kg combined by either with C. sativus 9 or 18 mg/kg. The standards group received losartan 2.25 mg/kg or 4.5 mg/kg (full dose). Results: Blood pressure was measured using the tail-cuff method. C. sativus significantly attenuated angiotensin II-induced hypertension as observed in groups receiving C. sativus at 9, 18, 27, and 36 mg/kg at 30 minutes after induction showed the average change (Δ) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) with respect to time zero were 28.8/18.3, 24.8/15.8, 22.8/15.5, and 11.5/9.0 mmHg, respectively. Whereas the average change (Δ) of SBP and DBP in the rats receiving the combination of half doses of C. sativus and losartan were 8.8/9.0 mmHg, respectively. These diminished effects were better than a full dose of C. sativus and comparable with a full dose of losartan (6.5/7.8 mmHg). Conclusion: The present findings indicate that C. sativus dose-dependently blocks blood pressure elevation induced by angiotensin II. The combination of half dose of C. sativus and losartan has an additive effect in lowering blood pressure.

Evaluation of Hemoglobin A1c Levels in Endometrial Cancer Patients: a Retrospective Study in Turkey

  • Karaman, Erbil;Karaman, Yasemin;Numanoglu, Ceyhun;Ark, Hasan Cemal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1817-1820
    • /
    • 2015
  • Background: Hemoglobin A1c(HgA1c) is a marker of poor gylcemic control and elevation HgA1c is associated with increased risk of many cancers. We aimed to determine the HgA1c levels in endometrial cancer cases and any relationship with stage and grade of disease. Materials and Methods: A retrospective data review was performed between June 2011 and October 2012 at a tertiary referral center in Turkey. The study included 35 surgically staged endometrial cancer patients and 40 healthy controls. Preoperative HgA1c levels drawn within 3 months before surgery were compared. Also the relationships between HgA1c levels and stage, grade and hystologic type of cancer cases were evaluated. Results: The mean HgA1c levels were statistically significantly higher at $6.19{\pm}1.44$ in endometrial cancer cases than the $5.61{\pm}0.58$ in controls (p=0.027). With endometrial cancer cases, the mean HgA1c level was found to be $6.62{\pm}1.40$ for stage I and $6.88{\pm}1.15$ for stages II-IV (p=0.07). The figures were $6.74{\pm}1.65$ for endometrioid and $6.63{\pm}1.41$ for non-endometrioid type tumors (p=0.56). Mean HgA1c levels of $6.72{\pm}1.14$ for grade 1 and $6.62{\pm}1.42$ for grade 2-3 were observed (p=0.57). Conclusions: HgA1c levels in endometrial cancer patients were statistically higher than healthy controls. However, HgA1c did not show any significant correlation with stage, grade and histologic type in endometrial cancer cases.