• 제목/요약/키워드: Helical Tube Bundle

검색결과 3건 처리시간 0.024초

가정용 흡수식 냉난방기의 나선형 흡수기 열물질전달 (Heat and mass transfer of helical absorber on household absorption chiller/heater)

  • 권오경;윤정인
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.570-578
    • /
    • 1999
  • An experimental study has been performed on heat and mass transfer in a falling film absorber with a strong lithium bromide solution in small-sized household absorption chiller/heater. Components were concentrically arranged in a cylindrical form. from the center, low temperature generator, absorber and evaporator. This arrangement of helical-typed heat exchangers allows to make the machine much more compact than conventional one. Experimental measurements were conducted with a helical absorber and the obtained data were compared with data in the literatures. The comparison revealed that the helical absorber tube provides a similar performance to existing tube bundle absorber in heat and mass transfer. As a result, the heat and mass transfer characteristics of helical type absorber showed the possibility of the reduction in size and weight of small] capacity absorption chiller/heater.

  • PDF

Fluidelastic instability of a curved tube array in single phase cross flow

  • Kang-Hee Lee;Heung-Seok Kang;Du-Ho Hong;Jong-In Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1118-1124
    • /
    • 2023
  • Experimental study on the fluidelastic instability (FEI) of a curved tube bundle in single phase downward cross flow is investigated for the design qualification and analysis input preparation of helical coiled steam generator tubing. A 6×9 normal square curved tube array with equal and different vertical/horizontal pitch-to-diameter ratio was under-tested up to 6 m/s in term of gap flow velocity to measure the critical velocity for FEI. The critical velocity for FEI was measured at the turning point from the vibration amplitude plot along the gap flow velocity. Our test results were compared with straight tube results and published data in the design guideline. The applicability of the current design guidelines to a curved tube bundle is also assessed. We found that introducing frequency difference in a curved tube array increases the critical velocity for fluidelastic instability.

원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 - (A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger-)

  • 이찬규;이종원
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.251-258
    • /
    • 1990
  • 본 연구에서는 제 1보에서 다루었던 프로세스 해석의 결과들을 토대로 하여 열교환기의 최적 설계를 행하는데 주력하였다. 먼저, 열교환기의 최적 설계를 행하 는데 주력하였다. 먼저, 열교환기의 열설계에 필요한 CO$_{2}$와 Natrium의 물성치 및 열전달에 관한 기존의 실험식들을 여러문헌으로부터 연구 검토한 후 프로그램에 편 리하게 이용할 수 있도록 전산화 하였으며, 열교환기의 설계시 필요한 전체 경비의 최 소화를 기하는 방향으로 최적화된 설계인자들을 결정하도록 시도하였고 또한 최적화된 프로그램을 개발함으로써 인력, 외화 및 에너지 절감의 효과를 얻고자 하였다.