• Title/Summary/Keyword: Helical

Search Result 1,160, Processing Time 0.025 seconds

Recent Advancement in the Differentiation of Tissues and Organs and Regulation of Gene Expression (조직.기관의 분화와 유전자 발현의 조절, 최근의 진보)

  • Harn, Chang-Yawl
    • Korean Journal of Plant Tissue Culture
    • /
    • v.24 no.1
    • /
    • pp.1-35
    • /
    • 1997
  • Fertilized egg, by successive cell divisions, differentiates into different tissues and organs with various structures and functions. Different cells and tissues contain different proteins, products of selective gene expression. Not all the genes in any genomes are equally active, temporal and spatial gene expression being the general rule. Present paper attempts to review the tanscriptional mechanisms or the initiations of transcription from several angles. In some of the organisms the genes in the process of transcription or the genes in the inactive state can be seen under the light microscope. Some bands of Drosophila polytene chromosomes may exhibit a swollen or puff appearance under certain conditions. A puff, unfolded or decondensed form of chromomere, represents sets of intense transcriptional activity or RNA synthesis. The heterochromatic X chromosome whose genes remain inactive in the female mammals can be visualized as a dark staining structure called Barr body, Configuration of chromatin differs between transcribed and nontranscribed chromatin. Modification to the chromatin facilitates RNA synthesis. The movement of large polymerase molecule along the DNA would probably be facilitated if some modifications of the chromatin configuration is effected. Methylation of cytosines in CG sequences is associated with inactive genes. Methylation can play a role in determination of mammalian cells during embryogenesis. Demethylation is necessary for the gene to be expressed during development A histone modification that is also known to be correlated with transcriptional capacity of chromatin is acetylation of the lysine residues of the core histones. Chromatin containing a high level of histone acetylation is very sensitive to DNase 1. For the transcription to occur TBP must first bind to the TATA box. Another TF, TF IIB, then binds to the promoter-TBP complex, facilitating the access of RNA polymerase to the transcription initiation site. As recently as eight years ago researchers assumed that histones were irrelevant to the regulation of gene expression. Histones combine with the DNA to form nucleosome of the chromatin. Histones are vital participant in gene regulation. Histone and basal factors compete for access to TATA box. When DNA is exposed to basal factors before histones are introduced, the basal factors assemble on TATA boxes preventing the access of histones, allowing transcription to occur, for transcription to begin, activator protein at the upstream activation sequence or enhancer must interact with the tail of histone H4 at TATA box and cause the histone role particle to dissociate from the TATA box leading to partial breakup of the histone core particle and allowing the basal factors to bind to the TATA box. New concept of genomic flux in contrast to the old concept of static genome has been developed based on the powerful new molecular techniques. Genomic changes such as repetitive DNAs and transposable elements, it is assumed but not yet proved, may affect some of the developmental patterns that characterize particular cells, tissues, organs, and organisms. In the last decade or so remarkable achievement have been made in the researches of the structures and functions of TFs and the specific target sequences located in promoters or enhancers where these TFs bind. TFs have independent domains that bind DNA and that activate transcription. DNA binding domain of TFs serves to bring the protein into the right location. There are many types of DNA binding domains. Common types of motifs can be found that are responsible for binding to DNA. The motifs are usually quite short and comprise only a small part of the protein structure. Steroid receptors have domains for hormone binding, DNA binding, and activating transcription. The zinc finger motif comprises a DNA binding domain. Leucine zipper consist of a stretch of amino acids with a leucine residue in every seventh position Two proteins form a dimer because they interact by means of leucine zippers on similar α-helical domain. This positions their DNA binding basic domains for interaction with the two halves of a DNA sequence with dyad symmetry of TGACTCA, ACTGAGT.

  • PDF

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

Experimental Study on Helical Turbine Efficiency for Tidal Current Power Plant (조류 발전용 헬리컬 수차의 효율에 대한 실험적 연구)

  • Han, Sang-Hun;Lee, Kwang-Soo;Yum, Ki-Dai;Park, Woo-Sun;Park, Jin-Soon;Yi, Jin-Hak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.530-534
    • /
    • 2006
  • 조류발전은 조류 유속이 빠른 곳에 수차발전기를 설치하여 해수의 운동에너지로부터 전기를 생산하는 발전방식이다. 2001년부터 해양연구원에서는 울돌목의 우수한 조류발전 개발 여건을 바탕으로 조류에너지 실용화 기술을 개발하고 있다. 본 연구에서는 조류발전 시스템에 사용되는 헬리컬 수차의 효율을 현장실험을 바탕으로 판단하고자 하였다. 현장실험을 위하여 지름 2.2 m, 높이 2.5 m의 수차를 제작하고, 울돌목 협수로의 한 쪽 면에 쟈켓구조물을 설치하여 수차를 거치한다. 수차가 회전함에 따라 회전봉에 일정 마찰을 주어 토크와 RPM을 측정하고, 함께 측정된 유속자료를 이용하여 수차를 효율을 산정한다. 유속-수차효율, TSR(수차의 날개속도와 유속의 비)-수차효율의 상관관계로 실험결과를 고찰하였다. 1중 날개 수차인 경우에 유속 1.4에서 2.6 m/s 사이에서 최대효율이 30 - 35 % 정도였고, 2중 날개 수차에 대한 실험에서는 유속 1.4에서 2.6 m/s 사이에서 최대수차효율이 25 - 35 % 사이임을 알 수 있었다. TSR과 최대수차효율의 상관관계는 실험 case별로 조금씩 다르다. 전체적으로 1중 날개의 경우가 최대수차효율에서 2중 날개보다 TSR 값이 조금 큰 경향을 나타냄을 알 수 있다. 이것은 1중 날개가 2중 날개보다 가벼워 좀 더 큰 RPM을 발생시켜서 나타난 현상으로 생각된다. 현재의 실험결과들을 이용하여 TSR과 최대수차효율을 상관관계를 나타내는 모델식을 도출하였다. 현장시험결과를 종합하면, 현장조류발전 시설이 최소 600 kW의 전력이 생산되기 위해서는 지름 3 m, 높이 3.6 m 인 수차 3개가 하나의 축에 설치되어야하는 것으로 계산되었다. 정격유속이 4.8 m/s이고 수차의 지름이 3m 라면, 최적 전력발생시의 RPM은 1중 날개의 경우 79이고 2중 날개의 경우는 63정도임을 추정할 수 있었다.촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 영상수위계는 우물통 등을 이용하는 기존 방법과 비교하여 구조물이 필요 없어 설치 비용이 저렴하고, 영상에 의한 하천 모니터링 기능을 자체적으로 가지고 있기 때문에 효율적이라고 할 수 있다.따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전

  • PDF

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma (흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향)

  • Park, Il-Hwan;Oh, Joong-Hwan;Lee, Chong-Kook
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.226-232
    • /
    • 2009
  • Background: Blunt chest trauma accounts for 90% of all chest traumas in Europe and the United States and this causes 20% of all trauma-related deaths. The major cause of morbidity and mortality after blunt chest trauma is undetected injuries. For this reason, chest computerized tomography has gained popularity for the evaluation of trauma, but it is expensive and it exposes patients to radiation. This study identified the clinical features associated with the diagnosic information obtained on a CT chest scan, as compared with a standard chest X-ray, for patients who sustained blunt trauma to the chest. This study also evaluated the role of a routine computed tomographic (CT) scan for these patients. The patients who had chest computed tomography done after the initial chest x-ray were analyzed separately for the presence of occult injuries. Material and Method: We studied 100 consecutive patients from November 2006 to July 2007: 74 patients after motor vehicle crashes and 26 patients after a fall from a height >2m. Simultaneous with the initial clinical evaluation, an anteroposterior chest radiograph and a helical chest CT scan were obtained for all the patients. The data extracted from the medical record included the vital signs, the interventions and the type and severity of injury (RTS). Result: Among the 100 cases, 79 patients showed at least more than one pathologic sign on their chest radiograph, and 21 patients had a normal chest radiograph. For 17 of the patients who had a normal chest X ray, the CT scan showed multiple injuries, which were pneumothorax, hemothorax, lung contusion, sternal fracture etc. This represents that a CT scan is statistically superior to a chest radiograph to diagnose the pathologic signs. But on the other hand, as for treatment, only 31 patients were diagnosed by CT scan and they were treated with chest tube insertion ect. 42 patients needed ony conservative management without invasive thoracosurgical treatment such as chest tube insertion or open thoracotomy. 27 patients were treated based on the diagnosis made by the chest radiograph and physical examination. Conclusion: Chest computerized tomography was significantly more effective than routine chest X-ray for detecting lung contusion, pneumothorax and mediastinal hematoma, as well as fractured ribs, scapula and, sternum. Although the occult findings increased, the number of patients who needed treatment was small. Therefore, we suggest making selective use of a CT scan to avoid its overuse in ERs.

A Study on the Characteristics of Oil-water Separation in Non-point Source Control Facility by Coalescence Mechanism of Spiral Buoyant Media (나선형 부유 고분자 여재의 Coalescence 특성을 이용한 비점오염원 저감시설의 유수분리특성 연구)

  • Kang, Sung-Won;Kim, Seog-Ku;Kim, Young-Im;Yun, Sang-Leen;Kim, Soo-Hae;Kim, Mee-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.950-955
    • /
    • 2007
  • Non-point source control system which had been designed only for oil-water separation in the fields of oil refinery and garage was upgraded in this research for the removal of runoff pollutants in impervious urban area. Pollutants including oil from driveway and bridge were eliminated by two types of pathway in the system. One is the coalescence mechanism that the oil droplets in the runoff come into contact with each other in the spiral buoyant media surface and form larger coalesced droplets of oil that are carried upstream to the oil layer. The other is the precipitation that solids in runoff were settled by gravity in the system. In this research, coalescing characteristics of oil and water separation were investigated through image analyses, and efficiencies of the non-point source control system were evaluated using dust in driveway and waste engine oil. Media made of high density and high molecular weight polyethylene was indeterminate helical shape and had sleek surface by analysing SEM photographs and BET. Surface area and specific gravity of media which were measured directly were 1,428 $mm^2$ and 45.3 $kg/m^3$ respectively. From the image analyses of the oil droplets photographs which were taken by using microscope, it was proved clearly that the coalescence was the main pathway in the removal of oil from the runoff. Finally, the performances of the non-point source control system filled up with the media were suspended solid $86.6\sim95.2%$, $COD_{Cr}$, $87.3\sim95.4%$, n-Hexane extractable materials $71.8\sim94.8%$ respectively.

Fine Structure of Mature Sperms of Cephalopods (Octopus minor, Octopus ocellatus and Todarodes pacificus) Inhabiting the Korean Waters II (한국 연근해산 두족류 (Octopus minor, Octopus ocellatus and Todarodes pacificus) 성숙정자의 미세구조 II)

  • Kim, Sang-Won;Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.31 no.4
    • /
    • pp.333-345
    • /
    • 2001
  • The mature sperms of three species of cephalopods (Octopus minar, Octopus ocellatus, Todarodes pacificus) were observed by electron microscopy. The results obtained are as follows: The sperm lengths of Octopus minor and Octopus ocellatus of octopods are long and they are about $390{\mu}m$ and $125\sim130{\mu}m$, respectively, but the sperm length of Todarodes pacificus is short and about $35{\mu}m$. The sperm of Octopus minor has a helical acrosome and a head bent a little like a banana while Octopus ocellatus of octopod has a twisted acrosome and a long rod-shaped head. A number of horizontal stripes are observed as a periodic structure in their subacrosome cavities and dense plugs are formed in the cavities of their heads. On the other hand, the acrosome of Todarodes pacificus is circular cap-shaped, and its head is long and oval. It is notable that two small cavities were observed in its basal acrosome. Juxtanuclear acrosomal materials of high electron density filled the subacrosomal cavity. In the middle piece of mature sperms of Octopus minor and Octopus ocellatus, the mitochondria form the mitochondrial sleeve, but the numbers of mitochondria differ between the species so that they are $11\sim12$ and $8\sim9$, respectively. Meanwhile, in the middle piece of mature sperms of Todarodes pacificus, the mitochondria are separated from the axoneme, forming a mitochondrial spur in which $10\sim13$ mitochondria and some electron dense materials concentrate. The axoneme of Octopus minor, Octopus ocellatus and Todarodes pacificus are of 9+2 type in common, surrounded by 9 coarse fibres. A number of glycogen were observed only in the axoneme of Todarodes pacificus. The coarse fibres were found as far as the main piece of sperm tail in Octopks minor and Todarodes pacificus, while to the end piece of sperm tail in Octopus ocellatus.

  • PDF

Experiences of the First 130 Patients in Gangnam Severance Hospital (강남세브란스병원 토모테라피를 이용한 치료환자의 130예 통계분석 및 경험)

  • Ha, Jin-Sook;Jeon, Mi-Jin;Kim, Sei-Joon;Kim, Jong-Dae;Shin, Dong-Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • Purpose: We are trying to analyze 130 patients' conditions by using our Helical Tomotherapy, which was installed in our center in Oct. 2007. We will be statistically approach this examination and analyze so that we will be able to figure out adaptive plans according to the change in place of the tumor, GTV (gross tumor volume), total amount of time it took, vector (${\upsilon}=\surd$x2+y2+z2) and the change in size of the tumor. Materials and Methods: Objectives were the patients who were medicated with Tomotherapy in our medical center since Oct. 2007 August 2008. The Average age of the patients were 53 years old (Minimum 25 years old, Maximum 83 years old). The parts of the body we operated were could be categorized as Head&neck (n=22), Chest (n=47), Abdomen (n=25), Pelvis (n=11), Bone (n=25). MVCT had acted on 2702 times, and also had acted on our adaptive plan toward patients who showed big difference in the size of tumor. Also, after equalizing our gained MVCT and kv-CT we checked up on the range of possible mistake, using x, y, z, roll and vector. We've also investigated on Set-up, MVCT, average time of operation and target volume. Results: Mean time on table was 22.8 minutes. Mean treatment time was 13.26 minutes. Mean correction (mm) was X=-0.7, Y=-1.4, Z=5.77, roll=0.29, vector=8.66 Head&neck patients had 2.96 mm less vector value in movement than patients of Chest, Abdomen, Bone. In increasing order, Head&neck, Bone, Abdomen, Chest, Pelvis showed the vector value in movement. Also, there were 27 patients for adaptive plan, 39 patients, who had long or multiple tumor. We could know that When medical treatment is one cure plan, it takes 32 minutes, and when medical treatment is two cure plan, it takes 40 minutes that one medical treatment takes 21 minutes, and the other medical treatment takes 19 minutes. Conclusion:With our basic tools, we could bring more accurate IMRT with MVCT. Also, through our daily image, we checked up on the change in tumor so that adaptive plan could work. It was made it possible to take the cure of long or multiple tumor, the cure in a nearby OAR, and the complicated cure that should make changes of gradient dose distribution.

  • PDF

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF

Changes in CGRP-immunoreactive Nerve Fibers during Expansion of Midpalatal Suture of the Rat (백서 정중구개봉합 확대후의 CGRP 면역반응 신경섬유의 변화)

  • Kim, Bo-Kyung;Park, Kuk-Pil;Kyung, Hee-Moon;Kwon, Oh-Won;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.73-81
    • /
    • 1999
  • Midpalatal suture expansion is often used for patients haying narrow maxillary arch, cleft palate, respiratory handicap with narrow nasal cavity. CGRP has been known as a modulator of pain transmission in central nervous system and a local effector to peripheral tissue causing vasodilation, increase of blood flow, modulation of immune system, regulation of macrophagic function and stimulation of bone formation. To investigate changes of CGRP-immunoreactive nerve fibers in midpalatal suture during the expansion, immunohistochemical study was performed by using rats. Experimental rats (10 weeks, 250 gm) were divided into five groups (control, 1, 4, 7, 14 days group (each n=4) and applied orthodontic force (approximately 200gm) to upper anterior incisors. Frozen sections of midpalatal suture area were immunostained by using rabbit antisera. The results were as follows. ${\cdot}$ The CGRP-immunoreactive nerve fibers were hardly observed in control group. ${\cdot}$ In 1 day group, the CGRP-immunoreactive nerve fibers were more increased around the vessels than control group. ${\cdot}$ In 4 days group, the CGRP-immunoreactive nerve fibers were more increased than control group, but not more increased than 1 day group. Vascular diameter was more enlarged. ${\cdot}$ In 7 days group, especially, hematoxilin affinity of cells was remarkable and cells were arranged along the bone margin. The CGRP-immunoreactive nerve fibers were more reduced than 4 days group and vascular diameter was also reduced. ${\cdot}$ In 14 days group, the CGRP-immunoreactive nerve fibers were similar to those of 7 days group and the irregularity of bone margin was almost recoverd. In Conclusion, the CGRP-immunoreactive nerve fibers nay be related to initial neurogenic inflammatory reaction in expanding mid-palatal suture.

  • PDF