• Title/Summary/Keyword: Helical

Search Result 1,160, Processing Time 0.024 seconds

Vibration Analysis of the Helical Gear System by Spectral Transfer Matrix (스펙트럴 전달행렬에 의한 헬리컬 기어계의 진동해석)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.774-781
    • /
    • 2006
  • This paper presents a study on the analytical prediction of vibration transmission from helical gears to the bearing. The proposed method is based on the application of the three dimensional helical gear behaviors and complete description of shaft by the spectral method. Helical gear system used in this paper consists of the driving element, helical gears, shafts, bearings, couplings and load element. In order to describe all translation and rotation motion of helical gears twelve degree of freedom equations of motion by the transmission error excitation are derived. Using these equations, transfer matrix for the helical gear is derived. For the detail behavior of shaft motion, the $12{\times}12$ transfer matrix for the shaft is derived. Transfer matrix for the bearing, coupling, driving element, and load is also derived. Application of the boundary conditions in the assembled transfer matrix produces the forces and displacements in each element of the helical gear system. The effect of the proposed method is shown by numerical example.

  • PDF

The Study of Effectiveness of Volume Mode in Pediatric CT (소아 전산화단층촬영에서 Volume Mode의 유용성 연구)

  • Park, Yun;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.425-431
    • /
    • 2014
  • The purpose of this study is to analyze dose comparison and image quality evaluation according to Volume and Helical mode using ATOM Phantom. It is to actively use the Volume mode in pediatric CT examinations. There was no significant difference with Helical and Volume in the value of Noise, HU, SNR(p>0.05). All dose values was no statistical difference(p>0.05). In the value of DLP and effective dose by part, Volume mode was measured lower than Helical mode. For qualitative analysis, by scan parameter helical mode showed respectively 2.6, 3.3, 4.36 and Volume mode indicated 2.8, 3.64, 4.44 point. Image evaluation for the follow-up, Helical mode and Volume mode were respectively 3.8 and 3.83. In fact, There was no significant difference. In CT scans in children under 5 years, because 640-MDCT Volume scan dose compared with Helical mode is lower and there is no significant difference with two modes in the image quality, 640-MDCT Volume scan is thought to be useful for pediatric CT scans.

Radiated Noise of Helical Gear-plate System (헬리컬기어-플레이트 시스템의 방사소음)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1042-1048
    • /
    • 2007
  • This work analytically investigated the radiated noise of a helical gear-housing system due to the excitation of helical gears. The helical gears were modeled as a 12-degree of freedom mass-spring-damper system; the shaft was modeled as a rod, a beam, and a torsional shaft; and the gear housing was modeled as a clamped circular plate with viscous damping. The modeling of this system used transfer matrices for helical gears, shafts, and bearings. Damping for both the bearings and the plate were obtained by modal testing. For the evaluation of noise, sound pressure from the plate due to the force and the moment in both radial and tangential directions was analytically derived by the Rayleigh integral. The analytical derivation and parameters from the experiment were applied to an analysis of noise for the two sets of helical gears with differing gear ratios. The analysis showed that the moment excitation in both helical gears contributed more to the noise of the plate than axial force excitation.

  • PDF

Experimental Study of Friction Factors for Laminar, Transition, and Turbulent Flow Regimes in Helical Coil Tubes (헬리컬 코일 튜브에서의 층류, 천이, 난류 영역의 마찰계수에 대한 실험적 연구)

  • Park, Won Ki;Kim, Taehoon;Do, Kyu Hyung;Han, Yong-Shik;Choi, Byung-Il
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The friction factors according to the flow regimes in helical coil tubes depend on the coil diameter, the tube diameter, and the coil pitch. In previous studies, correlations for the laminar flow regime in helical coil tubes have been proposed. However, studies on the transition flow regime and the turbulent flow regime are insufficient and further researches are necessary. In this study, characteristics of the friction factors for the laminar, transition and turbulent flow regimes in helical coil tubes were experimentally investigated. The helical coil tubes used in the experiments were made of copper. The curvature ratios of the helical coil tubes, which means the ratio of helical coil diameter to inner diameter of the helical coil tube are 24.5 and 90.9. Experiments were carried out in the range of $529{\leq}Re{\leq}39,406$ to observe the flows from the laminar to the turbulent regime. The friction factors were obtained by measuring the differential pressures according to the flow rates in the helical coil tubes while varying the curvature ratios of the helical coil tubes. Experimental data show that the friction factors for the helical coil tube with 24.5 in the curvature ratio of the helical coil tube were larger than those in the straight tube in all flow regimes. As the curvature ratio of the helical coil tube increases, the friction factor in turbulent flow regime tends to be equal to that of the straight tube. In addition, it was confirmed that the transition flow regimes in the helical coil tubes were much wider than those in the straight tube, also the critical Reynolds numbers were larger than those in the straight tube. The results obtained in this experimental study can be used as basic data for studies on the water hammer phenomenon in helical coil tubes.

A study on the characteristics of wide bandwidth connector for automotive communication (자동차 통신을 위한 광대역 커넥터 특성 연구)

  • Kim, Byeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2012
  • In this paper, helical wave wire have been proposed as the vehicle connector for the wireless access in vehicular environments(5.925GHz) communication. This helical slow wave connector is design by considering the properties of critical parameter like helical mean radius, helical pitch, helical wire radius and distance of helical wire to shield. The design simulation and results can be used to determine the most suitable helical wave wire dimensions for vehicle communication connector. The optimized WAVE connector inserted the helical wave wire has insertion loss less than -0.76dB at 5.925GHz. It provides 31% of insertion loss with good performance. Therefore, the simulated results can be effectively used for optimum design of high frequency connector for vehicle communication.

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

The Maximum Output Designs of Slotless BLDC Motor Using Helical Shape (Helical 형상의 슬롯리스 BLDC 전동기의 출력 최대화 설계)

  • Cha, Hyun-Rok;Baek, Seung-Hun;Yun, Cheol-Ho;Jung, Tae-Uk;Kim, Kwang-Heun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.793-794
    • /
    • 2006
  • 본 논문은 Slotless BLDC 모터를 고출력화 하기 위해서 나선형(Helical)방식을 적용하여 모터의 고출력화를 이루는 방식에 대한 연구이다. 기존의 SlotlessBLDC모터는 코깅이 없고, Slot이 없으므로 소형화에 유리한 장점을 지녔다. 반면에 공극의 자속 밀도가 낮아 출력을 높이는데 한계가 있었다. 따라서 본 논문에서는 기존의 SLBLDCM의 단점을 극복할 수 있는 Helical 방식을 제안하였다. Helical 방식을 적용할 때 기존의 인덕턴스 영향으로 인한 전류 확립에 한계가 있었으나 본 방식을 적용 시 높은 전류를 흘릴 수 있었으며 이로 인해 고출력화를 이룰 수 있었다. 아울러 Helical 방식을 취하므로 높은 전류로 인한 발열문제까지도 동시에 해결할 수 있는 장점이 있었다. 본 논문에서는 Helical 방식을 적용하여 기존대비 출력을 15%이상 향상시킬 수 있었으며, 온도 상승도 10%이상 억제할 수 있었다.

  • PDF

Design and fabrication of circular-polarization separator using a glancing angle deposition (Helical structure) (경사입사 증착법 (나선형 구조)을 이용한 원편광 분리소자의 설계 및 제작)

  • Park, Yong-Jun;HwangBo, Chang-Gwon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.151-152
    • /
    • 2007
  • In this study, the optical porosity of $TiO_2$ films with helical structure deposited by glancing angle deposition (GLAD) were investigated. Helical films are of interest due to their ability to differentiate states of circularly polarized light. We designed and fabricated normal-incidence circular-polarization separator deposited by GLAD (Helical structure). The optical porosity of $TiO_2$ film deposited by helical method can be applied many optical coatings.

  • PDF

Experiments on the Grinding Conditions for Helical Scan Grinding of a Glass Material (유리 재료의 헬리컬 스캔 연삭 조건 실험)

  • Lee, Dae-Uk;O, Chang-Jin;Lee, Eung-Seok;Kim, Ok-Hyeon;Kim, Seong-Cheong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.165-170
    • /
    • 2001
  • In normal grinding abrasive particles of a grinding wheel rotate on planes parallel to the direction of workpiece fred. which may induce continued scratch lines on ground surface as the workpiece feeds. Instead in helical scan grinding the planes make an angle, called a helical angle, with the feeding direction. Thus scratch lines produced by abrasive particles per one revolution are discontinued which implies that the generation of scratch lines are suppressed by the helical scan grinding. In this study some experimental works have been done on the helical scan grinding of glass to find the effects of grinding conditions on the surface roughness and estimate the optimal grinding conditions. The helical angle, fred rate, material removal rate and the wheel speed are taken as factors for three kinds of grinding wheels i.e., coarse(#140 mesh), medium(#400) and fine(#800) diamond wheels. The experiments are scheduled by Taguchi technique and ANOVA has been carried out for the interpretation of the results. As a result of this study effects of the factors are verified quantitatively showing that the major factors are changed according to the wheel's mesh size and the helical angle is one of the influencing factors on the surface quality.

  • PDF