• Title/Summary/Keyword: Height variation

Search Result 1,128, Processing Time 0.027 seconds

Redefinition of the Original Benchmark Height using Long-term Tide Observations Analysis and GPS Levelling Methods (장기간 조위관측자료 분석과 GPS 수준측량 수준원점 성과 재정의)

  • Jung, Tae-Jun;Yoon, Hong-Sic;Hwang, Jin-Sang;Lee, Dong-Ha
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.4
    • /
    • pp.393-403
    • /
    • 2011
  • In this study, we suggested the period of tide observations is proper to calculate the mean sea level(MSL) precisely on Incheon tide station using wavelet analysis, and newly determined then the vertical reference surface of Korea using the calculated MSL. In order to calculate the height difference between the calculated MSL and specific ground station (ICGP) near the Incheon tide stations, we performed the laser measurements directly to the sea surface where located below ICGP. The orthometric-height of ICGP was determined that corrected the height difference to the calculated MSL using linear interpolation method. Finally, we connected the orthometric-height of ICGP with the original benchmark (ORBM) using GPS leveling methods for determining the new orthometric-height of ORBM. As the results, there is a variation amount of 0.026m between the new MSL was calculated in this study and old MSL was calculated in 1910's. Also, there is a difference of 0.035m between the new and old orthometric-heights of ORBM. The connection (or leveling) error of 0.009m was revealed in new orthometric height of ORBM with consideration of MSL variation which may caused by the error of GPS ellipsoid height and/or geoid model. In this study, we could be determined precisely the orthometric-height of ORBM based on the new MSL of Incheon Bay using only GPS leveling method, not a spirit leveling method. Therefore, it is necessary to determine the vertical datum strictly using long-term and continuously tide observations more than 19 years and to use the GPS leveling method widely in the height leveling work for the effective changeover from the orthonormal to the orthometric in national height system.

Erosion Control Line (ECL) Establishment Using Coastal Erosion Width Prediction Model by High Wave Height (고파랑 해안 침식폭 예측모델을 이용한 침식한계선(ECL) 설정)

  • Park, Seung-Min;Park, Seol-Hwa;Lee, Jung-Lyul;Kim, Tae-Kon
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.526-534
    • /
    • 2019
  • The average coastline and the erosion control line introduced as the management coastline, and the average shoreline (MSL) was established from the observed coastline. Also, the median grain size and the wave height of 30-years return period were applied. The erosion control line (ECL) was established through the model, HaeSaBeeN. These two lines set the coastline for evaluation. Based on the observed monitoring data along the coastline, the 1-day variation according to the normal distribution was used to estimate the regional variation, and the width of the erosion was calculated by applying the median grain size (D50) and the wave height of 30-years return period through the high-wave coastal erosion width model, i.e., HaeSaBeeN.

The Experimental Study on the Natural Ventilation Performance of Solar Chimney by the variation of Insulation Thickness and Height (단열재의 두께 및 연돌높이에 따른 태양열 굴뚝의 자연환기 성능에 관한 실험적 연구)

  • Cho, S.W.;Kim, D.W.;Im, Y.B.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.39-46
    • /
    • 2002
  • The results of experiment on the performance of natural ventilation by insulation thickness and height system of solar chimney are described. The 3-inside wall was made of concrete and 1-wall was made of glass. The two kinds of model experiment were performed. One was the varition of the 60cm, 90cm and 120cm of solar chimney, the other was the variation of the insulation thickness 10mm and 50mm and without insulation of outside wall of solar cimney. As the temperature difference between bottom and top expressed $1.7\sim2.9^{\circ}C$, air velocity measured $0.5\sim0.8m/s$ and ventilation rate was $194.4m^3/h$ in the case of the 120cm height of solar chimney, the respect of natural ventilation performance was superior to others cases in the first model experiment. Though the case of 120cm height of solar chimney was attached 50mm insulation the ventilation rate was not so much as the case of solar chimney was attached 10mm insulation. the temperature difference between bottom and top was the largest in the other cases. From this research, the natural ventilation performance of solar chimney was affected by not only height and insulation thickness of solar chimney but also wind velocity and directon.

Laboratory Experiments of Stem Waves along a Vertical Structure under Overtopping Conditions (월파조건에서 직립구조물을 따른 연파실험)

  • Lee, Jong-In;Kim, Young-Taek
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1275-1292
    • /
    • 2012
  • This study investigates the characteristics of stem waves along a vertical structure under overtopping conditions through laboratory experiments in a wave basin. The uni-directional random waves with Bretschneider-Mitsuyasu frequency spectrum as incident waves were used. This study is focused on the reduction of wave height due to the variation of relative freeboard height (R) and the results for wave overtopping conditions are compared with those for non-overtopping conditions. Though the relative wave height along a vertical structure decreases with the decrease of relative freeboard, the variation of stem width is not significant. For the relative freeboard is greater than 1, the reduction effect of stem wave height by overtopping can be ignored in this experiments. The reduction effect of wave height along the structure for R =0.5 is about 10% comparing with R =1.5.

A Combustion Analysis of Surface Fuel Burning Experiment According to Density Variation (밀도에 따른 지표 연료의 연소실험 분석)

  • Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun;Park, Hyung-Ju;Kim, Jeong-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • This paper shows combustion characteristics of fallen leaves of Quercus variabilis and Pinus densiflora according to variation of mass densities. Combustion temperature, mass loss rate, flame height, duration of combustion and velocity of hot gas are measured and analyzed. For the experiment 10cm heighted baskets with varying diameters of 20, 30, 40 and 50cm are used for the combustion and the pilot ignition is carried on the top of the fuel. In case of Pinus densiflora mass loss rate, duration of flame, flame height and combustion time become larger as the mass density and diameter of basket increase, on the other hand Quercus variabilis shows saturation characteristics in mass loss rate and flame height. Velocity of hot gas is proportional to flame height.

Analysis of Flood Reduction Effect of Washlands based on Variation of Rollway Characteristic (월류부특성변화에 따른 천변저류지군의 홍수저감효과분석)

  • Baek, Chun-Woo;Kim, Bok-Cheon;Ahn, Tae-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.145-150
    • /
    • 2009
  • Because it is difficult to install new large hydraulic structure, washland is considered as alternatives of hydraulic facility. As flood reduction effect of washland is dependent on flood, hydrograph, capacity of washland and spillway height, applying adequate spillway height is very important to maximize flood reduction effect of washland. In this study, effect of variation of spillway height on flood reduction effect of washlands is analyzed. The existing model developed to make decision for optimal location of washland using flood reduction effect as evaluation function and location of washland as decision variable was revised for this purpose. The spillway height of washland is added as decision variable and revised model finally give optimal location and spillway height of washland as result. The developed model has been applied to the Ansung River basin and application result was compared with that of existing model. The application result shows that developed model can give more efficient result than existing model.

A Study on Operation Rate and Output of Wave Power Generator by Waves Condition (파랑 조건에 따른 파력발전장치의 가동률과 발전량 산정에 대한 연구)

  • Ryu, Hwang-Jin;Hong, Key-Yong;Shin, Seung-Ho;Kim, Sang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.615-619
    • /
    • 2009
  • This paper is investigated to variation of wave power generation operation rate, operating capacity and output with the wave conditions represented by wave height-period window. By the use of the long-term wave data from 1979 to 2002 which is provided by Korea Ocean Research & Development Institute(KORDI), we calculated the monthly variation of significant wave height(Hs), zero-up crossing period(Tz) and distribution of wave appearance rate. And using the same wave data, it was charted the Hs-Tz and wave-energy scatter diagrams.

  • PDF

Genetic Variability and Association of Yield Attributing Characters with Grain Yield in Deepwater Rice

  • Bose L. K.;Pradhan S. K.;Mohanty A.;Nagaraju M.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.4
    • /
    • pp.262-264
    • /
    • 2005
  • A study on genetic variability and association of yield attributing characters with grain yield was carried out using 35 deepwater rice genotypes. High genotypic co-efficient of variation (GCV) was observed for plot yield, $EBT/m^2$, plant height and days to $50\%$ flowering (DFF). For all the traits, estimates of the phenotypic co-efficient of variation (PCV) were higher than GCV, indicating presence of environmental influence. High heritability and genetic advance was observed for plot yield, $EBT/m^2$ and plant height. Plot yield had significant positive association with test weight, $EBT/m^2$ and DFF. However, test weight had the maximum direct effect on grain yield

Experimental Study on Adjustment of Inlet Nozzle Section to Flow Rate Variation for Darrieus-type Hydro-Turbine

  • Watanabe, Satoshi;Shimokawa, Kai;Furukawa, Akinori;Okuma, Kusuo;Matsushita, Daisuke
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.1
    • /
    • pp.30-37
    • /
    • 2012
  • A two dimensional Darrieus-type turbine has been proposed for the hydropower utilization of extra-low head less than 2m. In a practical use of Darrieus-type hydro-turbine, head and flow rate may be varied temporally and seasonally. Considering that the cost advantage is required for the low head hydro turbine system, the Darrieus turbine should be operated with high efficiency in the wider range of flow rate possibly by using an additional device with simpler mechanism. In the present paper, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed to obtain the preferable inlet velocity in low flow rate conditions. Effects of resulting spanwise partial inlet flow are investigated. Finally, an effective modification of inlet nozzle height over flow rate variation is shown.

Emission Characteristics of LP Gas Burner for the Variation of Combustion Conditions (연소조건 변화에 따른 LP가스버너의 배기특성)

  • 이병곤;오택흠
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • An experimental study was carried out to investigate the emission characteristics of LP gas burner for the Practical combustion conditions including fm voltage, inlet area, gas Pressure, emission resistance, duct length and height. The result shows that CO is almost remains constant for the emission fan voltage, but significantly increases with the reduction rate of air inlet, up to 3000ppm at 50% of reduction rate. Also, the variation of gas pressure has no effect to CO of gas boiler due to its governor which controls gas pressure secondly, but it gives an rapid increase of CO for the gas range. The emission resistance test shows that CO is suddenly increased with the reduction rate of emission duct above 70% and main burner is stopped at 90%. The reverse wind test shows that CO is suddenly increased with the air velocity above 7m/s and main burner is stopped at 9m/s. The more horizontal length of emission duct is long and the vertical height is low, CO is infinitesimally increased.

  • PDF