• 제목/요약/키워드: Height variation

검색결과 1,130건 처리시간 0.026초

왕복운동에서의 고유주파수 변화에 따른 마찰소음 특성 연구 (Characteristics of Friction Noise with Changes of the Natural Frequencies in the Reciprocating Motion)

  • 최호일;강재영
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.332-338
    • /
    • 2014
  • Experimental study is conducted for investigating the characteristics of friction-induced noise with respect to the variation of system geometry. In this study, a vertically fixed rod is in contact with the reciprocating plate which is controlled by the step motor. Friction noise is generated during the reciprocating motion due to the frictional contact between the plastic pin and the aluminum plate. The frequencies of the friction noise are changed when the height of the rod varies. However, it is found that the vibration modes involved in the friction noise are not changed. It implies that the unstable modes remain unstable regardless of the change of the system geometry, and thus, there are the certain mode shapes which are likely to produce friction noise.

Pilot plant 규모 유동충 소각로의 제지 슬러지 소각 용량에 관한 실험적 연구 (Experimental study on the capacity of pilot scale FBC for paper sludge)

  • 라승혁;문동진;강경태;신동훈;황정호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.199-203
    • /
    • 2002
  • In this paper, the effects of water contents on combustion characteristics of paper sludge and capacity of fluidized bed combustor(FBC) were investigated using 0.26m diameter, 1.75m height pilot-plant scale combustor. Combustion tests of paper sludge containing water contents between 40wt% and 50wt% were performed. The temperature and emission variation, the pressure inside combustor were measured to monitor the fluidization quality. The experimental results showed that 30kg/hr feeding rate of sludge containing water up to 45wt% was preferable for this system. Sludge loading rate, heat release rate were calculated from experimental data as major parameters showing FBC capacity. Comparsion with sludge loading rate from other source was also performed

  • PDF

Vertical emission rate variations of the O2 (0-0) Atmospheric band from TIMED Doppler Interferometer (TIDI)

  • Chung, Jong-Kyun;Wu, Qian
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.24.4-25
    • /
    • 2008
  • Limb scanning measurements of the O2 (0-0) Atmospheric band emission by the TIDI instrument aboard the TIMED satellite during 2003-2005 are analyzed to examine the tidal effects on their vertical emission rate according to the solar and geomagnetic activities. The data are restricted at latitudes $60^{\circ}S-60^{\circ}N$ to avoid the contributions by the auroral emission. The variation of the vertical emission rate in latitude and local time is summarized in the yaw periods. The vertical emission profiles of the O2 (0-0) Atmospheric band nightglow averaged in the $10^{\circ}$ latitude range are investigated. The result shows the inverse relationship between the peak emission height and the integrated brightness.

  • PDF

농도구배가 삼지화염의 부상특성에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Lift-off Characteristics of the Triple Flame with Concentration Gradient)

  • 서정일;김남일;오광철;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.7-14
    • /
    • 2004
  • The lift-off characteristics of the triple flame have been studied experimentally with various mean velocities and concentration gradients using a multi-slot burner, which can control the concentration gradient and the mean velocity independently, Lift-off height, axial maximum velocity, flame temperature, and some other characteristics were examined for methane and propane flame, It was found that minimum values of the lift-off heights exist at a certain concentration gradient for constant mean velocity, and this result implies that the propagation velocity has a maximum value at this condition, OH radical distribution was measured with LIF method and velocity variation along streamline was measured with PlV system. In addition maximum temperature along streamline was measured with CARS system. The intensity of the diffusion flame affects on the propagation velocity of triple flame in the region of very weak concentration gradient.

  • PDF

An Assessment of the Disability Glare by the Road Lighting System Installed on Guardrails

  • Seok, Dae-Il;Kim, Hoon
    • 조명전기설비학회논문지
    • /
    • 제24권3호
    • /
    • pp.1-7
    • /
    • 2010
  • To find an appropriate illuminance range for the disability glare caused by the road lighting system installed on guardrails, the influence of the disability glare was evaluated in comparison with the road lighting system of a streetlight. To test the disability glare, an indoor laboratory was constructed and a variation of luminance contrast threshold was evaluated. As a result, when the retinal illuminance was increased and glare sources existed within the narrow visual field, the luminance contrast threshold was increased. Although the road lighting luminaire was installed as low as the height of the guardrail on the road, when out of sight, the influence of the disability glare was small in comparison with the conventional road lighting system such as a streetlight.

주상복합의 실외기 형태에 따른 냉방시스템 성능 평가 (The performance evaluation of outdoor unit cooling system in a residential apartment complex)

  • 경서경;김윤진;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

슬러지침전속도를 고려한 새로운 슬러지침전특성지표의 설정에 관한 연구 (New Sludge Settling Characteristic Index Considering Sludge Settling Velocity)

  • 박석균;강선홍;김동하
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.451-460
    • /
    • 2006
  • While sludge settles down in a batch column, sludge concentration becomes high. Sludge concentration change is one of the most critical causes of the sludge settling velocity variation. Therefore, sludge concentration change causes sludge index to change. SVI is more sensitive than other sludge indexes to the change of sludge concentration. And if sludge-water interface has reached final height within 30minutes, SVI is not suitable for prediction of sludge settling characteristic, Therefore, SVIs of each sludge are, in some cases, different although each sludge has the same settling velocity. But SVI has been widely used to interpret sludge settling characteristic by a simple testing method. This work has two purposes. The first purpose is to predict sludge settling velocity by using sludge-water interface settling velocity. And the second purpose is to develop new sludge settling characteristic index to exactly interpret sludge settling characteristic by overcoming the limit of SVI.

다수의 불규칙 공동을 갖는 광주의 안정성에 관한 수치해석 (The Numerical Analysis of Pillar Stability with Multiple, Irregular Openings)

  • 민형기;임한욱
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.139-155
    • /
    • 2004
  • A room and pillar mining method has been adopting at the Jeungsun limestone mine. To check stability of pillar with multiple and irregular openings, the size, shape and spacing of rib pillar were first designed using some empirical suggestions. The Finite Difference Method(FDM)was used to analyze the pillar stability. Twelve different cases with the variation of K(horizontal/vertical stress)values, different height and different spacing of pillar were used in this study. Finally Mohr-Coulomb criterion was adopted to calculate the safety factors. Horizontal and vertical displacement, maximum and minimum principal stresses, range of plastic zone and safety factors were calculated at each case. As a result of analysis, the size of one block is 160m long, 70m wide, 40m high with 20m wide rib pillar and 20m square column pillar. The overall recovery at this case can be estimated about 40%.

  • PDF

조선시대 불전의 건축적구성과 창호형식의 관련성 연구 (A Study on the Interrelation of Architectural Composition and Type of Windows and Doors of the Main Buddhist Halls in Chosun Dynasty)

  • 곽동엽
    • 한국주거학회논문집
    • /
    • 제10권4호
    • /
    • pp.11-21
    • /
    • 1999
  • The purpose of this study is to analyze the interrelation of architectural composition and type of windows and doors in Korean traditional architecture. Windows and doors type, in Korean traditional architecture, is one of the important element which used to playa great role in building's physical fasade, so that used to subjected the building as a whole. In this study, the investigations on the totally 88 Korean Buddhist Temples are made, and the analysis are made according to the physical size of buildings (length and height of JUGAN), composition of JUGAN, and existence of RUGAK. The result of this study indicates that there are outstanding typical differences of traditional windows and doors in advance to variation in the physical size of building, though there are numerous interrelation between typical differences of traditional windows and doors and composition of building as a whole.

  • PDF

부산지역 빌딩 분포 상세화에 따른 중규모 순환 특성 (Characteristics of Mesoscale Circulation with the Detailed Building Distribution in Busan Metropolitan Area)

  • 손정옥;이화운;이순환
    • 한국환경과학회지
    • /
    • 제21권2호
    • /
    • pp.203-215
    • /
    • 2012
  • In order to clarify the impacts of thermal difference in atmospheric boundary layer due to the different sophistication of building information in Busan metropolitan areas, several numerical simulations were carried out. ACM (Albedo Calculation Model) and WRF (Weather Research and Forecasting) was applied for estimating albedo and meteorological elements in urban area, respectively. In comparison with coarse aggregated and small buildings, diurnal variation of albedo is highly frequent and its total value tend to be smaller in densely aggregated and tall buildings. Estimated TKE and sensible heat flux with sophisticatedly urban building parameterization is more resonable and valid values are mainly induced by urban building sophistication. The simulation results suggest that decreased albedo and increased roughness due to skyscraper plays an important role in the result of thermal change in atmospheric boundary layer.