• Title/Summary/Keyword: Height reproducibility

Search Result 36, Processing Time 0.02 seconds

Reproducibility and reliability of head posture obtained by the outer canthus indicator (Outer Canthus Indicator를 이용한 두부 자세 기록법의 재현성)

  • Kim, Young-Jae;Sohn, Byong-Wha;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.77-86
    • /
    • 2010
  • Objective: The purposes of this study were to evaluate the reproducibility and reliability of head posture obtained by registering outer canthus as a soft tissue landmark with the Outer Canthus Indicator (OCI). Methods: Twenty-one adults with normal facial morphology were enrolled in this study (mean age $27.5\;{\pm}\;1.72$ years). To register initial head posture, height of the outer canthus from the ear rod plane was measured using OCI. Head posture was reproduced by moving the head upwards and downwards until the outer canthus was in a straight line with the indicator set at a registered height. After the head posture is reproduced by two operators after two days, lateral photographs were taken. Computerized photometric analyses of the photographs were performed. Results: The head rotations around the transverse axis were $0.69\;{\pm}\;0.43^{\circ}$, $0.98\;{\pm}\;0.65^{\circ}$ from each of the two operators. Standard errors were $0.09^{\circ}$ and $0.14^{\circ}$ each, which were similar to results from past research findings. There were no significant differences between the data from the two operators (p > 0.05). There were no correlations between the head rotation around the horizontal and vertical axes (p > 0.05). Conclusions: The present study suggests that OCI-registered head posture may minimize errors from vertical head rotation in cephalometry and photometry.

Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration (이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석)

  • Kim, Hak-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

A study of Tailored Blank Welding between dissimiliar materials and different thickness sheets by $CO_2$ Laser Beam ($CO_2$ 레이저빔에 의한 이종재질 및 이종두께의 Tailored Blank 용접에 관한 연구)

  • 황창선;김도훈;유병길;이경돈
    • Laser Solutions
    • /
    • v.2 no.3
    • /
    • pp.42-51
    • /
    • 1999
  • This research was conducted as a fundamental study to apply tailored blank welding technique into automotive production process. The materials used in this study were 2.0mm thickness low carbon steel sheets and 1.2mm Zn-coated low carbon steel sheets. To ensure the reproducibility and to consider various factors, experiments were. conducted by applying Taguchi experimental method with 6 factors. Every welding process was repeated 3 times to offset the effect of uncontrolled factors. Elongation and LDH(Limited Dome Height)were measured to evaluate formability of specimens and Optical microscopy, XRD, SEM, and EDS analysis were performed to observe the microstructures and to determine the solidification mode in the weld. The elongation of specimen welded with optimum condition was 83% of base metal, and LDH was 84% of base metal. In case of laser treated specimen where Zn coating was removed, elongation was 85% of base metal, and LDH was 85% of base metal. In fusion zone, phases were consisted of quasi-polygonal ferrite, banitic ferrite, and martensite.

  • PDF

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

Effectiveness Evaluation of Scanogram Using Longbone Detector (Longbone 검출기를 이용한 Scanogram의 유효성 평가)

  • Jang, Su-han;Heo, Ji-eun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.235-242
    • /
    • 2020
  • Scanogram is that combine several practical images into one image to observation. So it is an important consideration in many clinical situation such as iliac measurement, leg alignment measurement and Scoliosis. Currently, scanogram examinations are mainly conducted for children and elderly patients. In this study, in order to apply the longbone detector to children or elderly patients who are difficult to cooperate with, we compared the longbone detector from D equipment with the G equipment discovery 656 Puls equipment in reproducibility of images, distribution of irradiation dose, scattering dose, irradiation time and image acquisition time. D equipment took more than twice as much time as G equipment. The scattered dose generated about 50% more G equipment than D equipment. In the whole spine scanogram and the measurement length of the lower leg, D equipment was also measured longer than G equipment. However, both methods did not show much difference from the CT scanogram, so there was no problem in measurement. The height of the thyroid radiation dose of G equipment was produced more radiation than D equipment. However, the longbone detector deviated from the x-ray center line relative to the tube rotation method, and was measured lower by the directionality of the measuring instrument, so that the error could not be corrected. In the conclusion of study, using the longbone detector is excellent for applying to children or elderly patients to reduce scattering dose. However, using CR may be useful to normal patients. Because, the image quality may deteriorate due to an imbalance of dose difference in thickness depending on the body part. So, it is useful to using a compensation filter or tube rotation method when we take a whole spine scanogram.

The Effect of After-treatment on the Permeability of Polysulfone Hollow Fiber Membranes (후처리조건에 따른 한외여과용 폴리설포중공사막의 투과특성에 관한 연구)

  • 박유인;김정훈;이규호
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.67-73
    • /
    • 1992
  • The effects of after-treatment condition on the permeability of polysulfone hollow fiber membranes were investigated. It was well known that the permeability of and the rejection of hollow fiber membranes prepared by dry-wet spinning technique was highly affected by spinning conditions such as composition of spinning solution, inner and outer coagulant and spinning height. But these are also governed by after-treatment condition such as drying, hot water treatment and glycerine treatment. Since it was difficult to remove DMAc and NMP in membranes by washing with in cold water and even traces of such solvent affected the reproducibility of the membrane characteristics, the hot water-treatment should be required.

  • PDF

Assessment of variability and uncertainty in bias correction parameters for radar rainfall estimates based on topographical characteristics (지형학적 특성을 고려한 레이더 강수량 편의보정 매개변수의 변동성 및 불확실성 분석)

  • Kim, Tae-Jeong;Ban, Woo-Sik;Kwon, Hyun-Han
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.9
    • /
    • pp.589-601
    • /
    • 2019
  • Various applications of radar rainfall data have been actively employed in the field of hydro-meteorology. Since radar rainfall is estimated by using predefined reflectivity-rainfall intensity relationships, they may not have sufficient reproducibility of observations. In this study, a generalized linear model is introduced to better capture the Z-R relationship in the context of bias correction within a Bayesian regression framework. The bias-corrected radar rainfall with the generalized linear model is more accurate than the widely used mean field bias correction method. In addition, we analyzed variability of the bias correction parameters under various geomorphological conditions such as the height of the weather station and the separation distance from the radar. The identified relationship is finally used to derive a regionalized formula which can provide bias correction factors over the entire watershed. It can be concluded that the bias correction parameters and regionalized method obtained from this study could be useful in the field of radar hydrology.

Analysis of Wave Characteristics near Wangdeungdo through Southwest Sea Wave Hindcasting (서남해 파랑 후측모의 실험을 통한 왕등도 인근 파랑 특성 분석)

  • Young Ju Noh;Min Young Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.36 no.2
    • /
    • pp.61-69
    • /
    • 2024
  • Wave conditions are crucial for offshore wind farm design, particularly in determining structural loads and layout. However, there is limited wave hindcasting research for the Wangdeungdo Island area, a potential offshore wind site. This study used the MIKE21 model for a year-long wave hindcast around Wangdeungdo in 2021. Validation showed high reproducibility for significant wave heights with RMSE values of 0.177 and 0.225 and Pearson correlations of 0.971 and 0.970 at Sangwangdeungdo and Buan buoys. Subsequent analysis of the wave characteristics near Wangdeungdo indicated significant seasonal variations and differences in maximum significant wave heights across locations, which are expected to significantly impact the design loads for offshore wind structures.

Reliability of the Sundsvall Method for Femoral Offset Evaluation

  • Patrick Kelly;Caitlin Grant;Niall Cochrane;Jonathan Florance;Michael Bolognesi;Sean Ryan
    • Hip & pelvis
    • /
    • v.36 no.3
    • /
    • pp.218-222
    • /
    • 2024
  • Purpose: Acetabular and femoral offset (FO) play an important role in total hip arthroplasty (THA). The Sundsvall method has been proposed to account for both FO and cup offset in one global hip offset measurement. In this study, we examine the agreement and inter-observer reliability of the Sundsvall method of hip offset measurement. Materials and Methods: Four hundred and ninety-nine THA patients at a single tertiary academic institution were retrospectively reviewed. Preoperative hip offset was measured on anteroposterior radiographs of the pelvis on the operative and contralateral side. Hip offset was also measured postoperatively on the operative side. Hip offset was measured using the Sundsvall method as the distance between the femoral axis and midline of the pelvis at the height of the lateral most point of the greater trochanter. All measurements were completed by two raters. Intra-class correlation coefficients (ICC) and Pearson's correlation coefficients were used to evaluate agreement and inter-observer reliability between two raters. Results: There was excellent agreement between raters for preoperative hip offset measurement with an ICC of 0.91 (confidence interval [CI] 0.90-0.93, P<0.01) and R=0.92. There was excellent agreement between raters for postoperative hip offset with an ICC of 0.93 (CI 0.92-0.94, P<0.01) and R=0.93. Conclusion: This study confirms the inter-observer agreement and reliability of the Sundsvall method of hip offset measurement. With its high agreement and reliability, the Sundsvall method is an easy and reliable way to measure hip offset that can be applied in future clinical and research settings.

Peak Expiratory Flow(PEF) Measured by Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters in Healthy Children (정상 소아에서 최고호기유량계(peak flow meter)로 측정한 최고호기유량(PEF)와 기타 환기기능검사와의 상관관계)

  • Oak, Chul-Ho;Sohn, Kai-Hag;Park, Ki-Ryong;Cho, Hyun-Myung;Jang, Tae-Won;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.248-259
    • /
    • 2001
  • Background : In diagnosis or monitor of the airway obstruction in bronchial asthma, the measurement of $FEV_1$ in the standard method because of its reproducibility and accuracy. But the measurement of peak expiratory flow(PEF) by peak flow meter is much simpler and easier than that of $FEV_1$ especially in children. Yet there have been still no data of the predicted normal values of PEF measured by peak flow meter in Korean children. This study was conducted to provide equations to predict the normal value of PEF and correlation between PEF and $FEV_1$ in healthy children. Method : PEF was measured by MiniWright peak flow meter, and the forced expiratory volume and the maximum expiratory flow volume curves were measured by Microspiro HI 501(Chest Co.) in 346 healthy children(age:5-16 years, 194 boys and 152 girls) without any respiratory symptoms during 2 weeks before the study. The regression equations for various ventilatory parameters according to age and/or height, and the regression equations of $FEV_1$ by PEF were derived. Results : 1. The regression equation for PEF(L/min) was: $12.6{\times}$age(year)+$3.4{\times}$height(cm)-263($R^2=0.85$) in boys, and $6{\times}$age(year)+$3.9{\times}$height(cm)-293($R^2=0.82$) in girls. 2. The value of FEFmax(L/sec) derived from the maximum expiratory flow volume curves was multiplied by 60 to compare with PEF(L/min), and PEF was faster by 125 L/min in boys and 118 L/min in girls, respectively. 3. The regression equation for $FEV_1$(ml) by PEF(L/min) was:$7{\times}$PEF-550($R^2=0.82$) in boys, and $5.8{\times}$PEF-146 ($R^2=0.81$) in girls, respectively. Conclusion : This study provides regression equations predicting the normal values of PEF by age and/or height in children. And the equations for $FEV_1$, a gold standard of ventilatory function, was predicted by PEF. So, in taking care of children with airway obstruction, PEF measured by the peak flow meter can provide useful information.

  • PDF