Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration

이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석

  • Kim, Hak-Chul (Korea Water Resources Research Institutes, Kwater)
  • 김학철 (한국수자원공사 수자원연구원)
  • Published : 2006.12.30

Abstract

This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

Keywords

References

  1. S.C. Weldelken, L.E. Vanatta, D.E. Coleman, D.J. Munch, Journal of Chromatography A, 1118,94-99,(2006) https://doi.org/10.1016/j.chroma.2006.02.023
  2. Sarah J. Stetson, Richard B. Wanty, Dennis R. Helsel, Stephen J. Kalkhoff, Donald L. Macalady, Aanalytical Chimica Acta, 567, 108-111(2006) https://doi.org/10.1016/j.aca.2006.03.030
  3. He Huang, George A, Sorail, Chemosphere, 64, 1150-1156(2006) https://doi.org/10.1016/j.chemosphere.2005.11.044
  4. R. Slingsby, C. Pohl, C. Saini, Aanalytical Chimica Acta, 567, 57-65(2006) https://doi.org/10.1016/j.aca.2006.01.043
  5. Johnson Mathew, Jay Gandhi, Joe Hedrick, Journal of Chromatography A, 1085, 54-59,(2005) https://doi.org/10.1016/j.chroma.2005.05.015
  6. Yong-keun Lee, Bull. Korean. Chem. Soc, 15, 1045-1049(1994)
  7. Daniel P. Hautman and David J. Munch, US EPA, Determination of Perchlorate in Drinking Water Using Ion Chromatography, Method 314.0, Nov.(1999)
  8. 'Determination of Perchlorate by Ion Chromatography.' State of California, Department of Health Services, Sanitation and Radiation Laboratories Branch, Rev. No. 0 (June 3, 1997)
  9. 'Analysis of Low Concentrations of Perchlorate in Drinking Water and Ground Water by Ion Chromatography.' Application Note 121, Dionex Corporation, Sunnyvale, CA(1998)
  10. 'Perchlorate by Ion Chromatography, Modified EPA 300.0 Using IonPac AS11.' Standard Operating Procedure, Montgomery Watson Laboratories (March 17, 1998)
  11. Jackson, P,E.; Laikhtman, M.; and Rohrer, J.S. 'Determination of Trace Level Perchlorate in Drinking Water and Ground Water by Ion Chromatography,' Journal of Chromatography A, 850 (1999), 131-135 https://doi.org/10.1016/S0021-9673(99)00026-6
  12. Okamoto, H.S.; Rishi, D.K; Steeber, W.R; Baumann, F.J.; and Perera, S.K. 'Using Ion Chrormtography to Detect PercWorate,' Journal AWWA, Vol. 91 (October 1999), 73-84 https://doi.org/10.1002/j.1551-8833.1999.tb08717.x
  13. Inter-Agency Perchlorate Steering Committee, Analytical Subcommittee Report (1998). Report on the interlaboratory validation of IC methods for perchlorate
  14. Glaser, J.A.; Foerst, D.L.; McKee, G.D.; Quave, S.A. and Budde, W.L. 'Trace Analyses for Wastewater,' Environmental Science and Technology, Vol. 15, Number 12, page 1426, December, 1981 https://doi.org/10.1021/es00094a002
  15. 'OSHA Safety and Health Standards, General Industry,' (29CFR1910). Occupational Safety and health Administration, OSHA 2206, (Revised, Jan. 1976). 10. ASTM Annual Book of Standards, Part II, Volume 11.01, D3370-82, 'Standard Practice for Sampling Water,' Amencan Society for Testihg and Materials, Philadelphia, PA, 1986
  16. 'Carcinogens-Working with Carcinogens,' Publication No. 77-206, Department of Health, Education, and Welfare, Public Health Service, Center for Disease control, National Institute of Occupational Safety and health, Atlanta, Georgia, August 1977
  17. 'Safety In Academic Chemistry laboratories,' 3rd Edition, American Chemical Society Publication, Committee on Chemical Safety, Washington, D.C., 1979
  18. U.S. EPA Method 300.1. EPA Document number; EPA/600/R-98/118. NTIS number PB98-169196 INZ. 14. 'Anion Self-Regenerating Suppressor (ASRS) Quickstart Procedure', Document Number 031368-01, Dionex Corporation, Sunnyvale, CA, March, 1988