• Title/Summary/Keyword: Height of the table

Search Result 288, Processing Time 0.032 seconds

Table Detection from Document Image using Vertical Arrangement of Text Blocks

  • Tran, Dieu Ni;Tran, Tuan Anh;Oh, Aran;Kim, Soo Hyung;Na, In Seop
    • International Journal of Contents
    • /
    • v.11 no.4
    • /
    • pp.77-85
    • /
    • 2015
  • Table detection is a challenging problem and plays an important role in document layout analysis. In this paper, we propose an effective method to identify the table region from document images. First, the regions of interest (ROIs) are recognized as the table candidates. In each ROI, we locate text components and extract text blocks. After that, we check all text blocks to determine if they are arranged horizontally or vertically and compare the height of each text block with the average height. If the text blocks satisfy a series of rules, the ROI is regarded as a table. Experiments on the ICDAR 2013 dataset show that the results obtained are very encouraging. This proves the effectiveness and superiority of our proposed method.

Evaluation of Radiation Dose and Image Quality according to CT Table Height (CT 테이블 높이에 따른 방사선 선량 및 화질 평가)

  • Lee, Jongwoong;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.453-458
    • /
    • 2017
  • Computed Tomography (CT) provides information on the Diagnostic Reference Level Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP) for accurate diagnosis of patients. However, it does not provide a dose change according to the table height for the diagnostic reference level provided by the CT equipment. The purpose of this study was to evaluate the image and dose according to the table height change using phantom (PMMA: Polymethyl Methacrylate) in order to find the optimal image and the minimum dose during computed tomography examination. When examining using a 32 cm PMMA phantom with the same thickness as the abdomen of an adult, there was little change in dose with table height. However, the noise evaluation of the image caused a high fluctuation of noise depending on the table height. and in the case of the 16 cm PMMA phantom, the change of the noise was small, but the dose change was about 30%. In conclusion, the location of the patient and the center of the detector are important during computed tomography (CT) examinations. In addition, table height setting is considered to be important for examinations with optimized image and minimum dose.

A Study on the Rating of the Insureds' Anthropometric Data I. Build (피보험체계측치(被保險體計測値)의 평가(評價)에 관한 연구(硏究) 제1보(第1報) 체격(體格))

  • Im, Young-Hoon
    • The Journal of the Korean life insurance medical association
    • /
    • v.3 no.1
    • /
    • pp.103-141
    • /
    • 1986
  • The present study was undertaken to establish the decision standard of builds for the insured by using the ratio of weight-for-height as build index. Materials being examined were the ratio of weight-for-height being calculated from the actually measured heights and weights of a total of 15,838 insured persons who were examined medically at Honam Medical Department of Dong Bang Life Insurance Company, Ltd. from June, 1979 to September, 1985. The ratio of weight-for-height is calculated by the following formula. The ratio of weight-for-height(%)=$\frac{weight(kg){\times}100}{\{height(cm)-100\}{\times}0.9(kg)$ The results were as follows: 1. The distribution of the ratio of weight. for-height of the 15,838 insureds follows Log normal distribution being skewed to the left(the direction of underweight). 2. The ratio of weight-for-height were Log transformed to lead to a sym metrical pattern of distribution in which statistical rules are known to be applied more exactly. Thereafter, the establishment of dicision standard of builds was undertaken by using the log of the ratio of weight-for-height as build index. Through all ages in male, the ratio of weight-for-height indicating the range of standard lives including slight overweighted and underweighted lives besides normal lives is 80-130%, and corresponds to $"M-2{\delta}"-"M+1.5{\delta}"$ and to $M{\pm}20%$ ; in female, 85-135%, and corresponds to $"M-2{\delta}"-"M+1.5{\delta}"$ and to $M{\pm}20%$. Through all ages in male, the ratio of weight-for-height indicating the initial level of super-overweighted and super-underweighted lives is 130-150% and 75-80%,and corresponds to $M+3{\delta}\;and\;M-3{\delta}$ and to M+40% and M-25% respectively;in female, 140-160% and 75-80%, and corresponds to $M+3{\delta}\;and\;M-3{\delta}$ and to M+40%-+50% and M-25% respectively. 3. Author's rating table model for builds(a table of weight per height) is proposed. On the table, the ratings for builds, i. e. standard, super-weighted and super-underweighted lives, are listed.

  • PDF

On the Suitability of the volume table based upon D.B.H. and Height now in use (현행(現行) 이변수재적표(二變數材積表)의 적합성(適合性)에 대(對)하여)

  • Kim, D.C.
    • Journal of Korean Society of Forest Science
    • /
    • v.5 no.1
    • /
    • pp.1-3
    • /
    • 1966
  • According to the test of suitability on the acting volume table based upon D.B.H. and Height, the volume by the standing volume table of soft woods produced in Kangwon Province is larger than the true volume and the volume by the standing volume table prepared in form factor 0.45 is smaller than the true volume on the all species obviously. But the volume by the standing volume table of the red pine produced in Kangwon Province and that of Korean white pine prepared in Forest Expriment Station equal to the true volume well.

  • PDF

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

A Study on the Exhaust Performance of Contaminant by Establishment Height of Hood (랜지후드의 설치 높이에 따른 오염물질의 배출성능에 관한 연구)

  • 송필동;박명길;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2001.11a
    • /
    • pp.99-104
    • /
    • 2001
  • This paper is contents that experiment exhaust performance of contaminant by establishment height gas table and hood establishment height. Hood made to control from gas table to 10 centimeters space from 30 centimeters to 70 centimeters. Exhaust fan operated by 110V, 160V, 220V, and gas used propane gas. Center part appeared highest as result that measure wind velocity and temperature from hood lower part. Wind velocity from hood lower part was proved that dominate contaminant exhaust performance. Exhaust performance of carbon dioxide and heat showed that 30 centimeters case overmatches because establishment height of hood compares 80 centimeters. Case of carbon dioxide of exhaust performance by establishment height of hood overmatched more than heat.

  • PDF

A analysis of Proper Workbench for Body Type of Dental Technician (치과기공사의 체형에 적합한 작업대의 분석)

  • Han, Min-Soo;Choi, Esther;Oh, Seon-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.328-335
    • /
    • 2013
  • The purpose of this study was to evaluate the height of workbench in dental lab for ergonomic body type which dental technicians are suitable and suggest to effective improvement of workspace. For this purpose, we measured the height, weight, body sizes of total 77 junior majoring in dental laboratory science where they study school located in Gyeonggi and Chungcheong area and we research uncomfortable body type when they had a clinical training. For comparative analysis we had visited 15 dental lab and 2 dental lab of general hospital and we had measured the height of workbench and desk including chair and then We had statistical analysis measured value. Especially we analyzed the important factor causing inconvenience for work environment. As a result, we had examined, we found following results The sand table was the most uncomfortable equipment, when they have clinical training. There is no correlation between sexual characteristics of junior in college and selection of uncomfortable equipment. It is reasonable to assume that sand table which is lower than recommended height brings out inconvenience. It is analyzed that the optimum height of sand table in dental lab for junior in college is lower than the recommended height. The optimum height of sand table in dental lab has deviation according to height of junior in college. The height of worktable in dental lab was lower than recommended height. The recommended range could not apply to posture of dental technician with different height uniformly.

Sediment Properties and Growth of Phragmites australis in Mud Tidal Flat (조간대 저토 환경과 갈대의 생장 특성)

  • Min, Byeong Mee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.3
    • /
    • pp.57-69
    • /
    • 2011
  • This study examined the relationship between Phragmites australis' growth and sediment properties at mud tidal flat of Donggum-ri, Gilsang-myeon, Gangwha-gun, Incheon city. Field survey was carried out from May, 2010 to October, 2010. Water content, soil texture, electric conductivity and water table depth for sediment, density, height, dry weight and flowering for P. australis were examined at several plots from the starting point (the coastal embankment) to the end point of the two populations. The result was as follows. Firstly, the water table increased along distance from the embankment at one line (N-line) but was similar at the other line (S-line) in a P. asustralis population. Water tables were higher out of than within a P. australis population at two populations. Secondary, in N-line, the height and dry weight of P. australis decreased along the distance from embankment but, in S-line, those were similar in its population. P. australis' growth was dependent on electric conductivity at lower layer (water table level) rather than upper one (the surface). Thirdly, density of P. australis changed during growing season and was similar in a population, except for the end point of patch. In summary, the growth and distribution of P. australis were dependent on salt content of tidal flat's sediment (water table level) and this was affected by fresh water of the inland.

Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test (진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가)

  • Ha, Ik-Soo;Kim, Yong-Seong;Seo, Min-Woo;Park, Dong-Soon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

A Comparison of Endotracheal Intubation using the Macintosh Laryngoscope, the Gum Elastic Bougie and the Pentax AirWay Scope in Neck-Stabilized Manikin (경추 고정 마네킹에게 직접 후두경(Macintosh laryngoscope), 부지(Gum elastic bougie), 비디오 후두경(Pentax AirWay Scope)을 사용한 기관내삽관 비교)

  • Choi, Uk-Jin;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.3
    • /
    • pp.71-80
    • /
    • 2011
  • Purpose : This research was designed to provide basic data for advanced pre-hospital airway management by comparing the ease of intubation, the success rate and the time for intubation performed with Macintosh Laryngoscope, Gum Elastic Bougie and Pentax AirWay Scope on the floor and table. Methods : Intubation was performed 30 times in total, including 5 times for each of intubation using Macintosh Laryngoscope, Gum Elastic Bougie and Pentax Airway Scope on the table and floor, only on subjects who passed the practice test of the national exam for paramedics. Data were collected by measuring the ease of intubation, the success rate and the time for intubation, and then analyzed by descriptive analysis, paired t-test, ANOVA using SPSS 18.0. Results : 1. There was a significant difference in the ease of intubation according to intubation devices. 2. There was a significant difference in the ease of intubation according to table height for intubation. 3. There was a significant difference in the success rate according to intubation devices. 4. There was no significant difference in the success rate according to table height for intubation. 5. There was a significant difference in the intubation time according to intubation devices. 6. There was a partially significant difference in the intubation time according to table height for intubation. Conclusion : Sufficient training not only with Macintosh Laryngoscope but also with Gum Elastic Bougie and Pentax Airway Scope could improve the survival rate by intubation in patients with difficult airway.