• 제목/요약/키워드: Heavy-weight floor Impact Noise

검색결과 121건 처리시간 0.023초

주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가 (Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment)

  • 전진용;김경호;정정호;류종관;조문재
    • 한국소음진동공학회논문집
    • /
    • 제12권6호
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

유한요소해석을 이용한 공동주택의 중량충격음 예측 (Prediction of Heavy-Weight Floor Impact Sound in Multi-unit House using Finite Element Analysis)

  • 문대호;이상현;황재승;백길옥;박홍근
    • 한국전산구조공학회논문집
    • /
    • 제28권6호
    • /
    • pp.645-657
    • /
    • 2015
  • 본 논문에서는 유한요소법을 이용하여 공동주택의 중량충격음을 예측하기 위해 구조해석 모델과 음향해석 모델을 개발하고 예측결과와 실험결과를 비교하여 정확성을 검증하였다. 패널 임피던스 값을 사용하여 거실의 적절한 흡음 특성을 반영할 수 있었으며, 수치해석에 주파수 응답함수 특성을 적용하여 1회 수치해석만으로 다양한 충격원에 대한 응답을 예측할 수 있도록 하였다. 구조진동에 의한 실내 소음해석은 유한요소 수치해석 기법이 진동 및 음향모드에 대한 응답을 비교적 정확하게 예측할 수 있도록 하였으며, 본 연구의 예측결과는 실험결과와 비교적 유사한 값을 나타내었다. 향후 정확도가 보다 향상된 수치해석 모델개발을 통해 바닥충격음 저감에 효과적인 공동주택 설계가 가능할 것으로 판단된다.

단면 회복용 중량 모르타르를 사용한 철근콘크리트 슬래브의 음압 및 진동 특성 (Sound Pressure and Vibration Characteristics of Reinforced Concrete Slab with Heavy Weight Mortar for Cross-section Recovery)

  • 김재성;김진만
    • 한국건설순환자원학회논문집
    • /
    • 제12권3호
    • /
    • pp.298-305
    • /
    • 2024
  • 본 논문은 철근콘크리트 슬래브의 바닥 충격음을 개선하기 위한 기초연구이다. 시공에 의해 두께의 차이가 발생하는 경우를 고려하여 철근콘크리트 슬래브의 단면을 모르타르로 회복시켰을 경우 차음 특성의 변화를 분석 하였다. 분석 대상 주택은 평면형식이 다른 84 type와 59 type의 2종류로 하였으며, 철근콘크리트 슬래브 위에 단면을 회복하기 위해 중량모르타르로 단면 회복용 모르타르 시공할 때를 철근콘크리트 슬래브 단독과 일반 모르타르로 단면 회복용 모르타르 시공한 경우와 비교하여 진동가속도레벨과 음압의 차이를 측정하였다. 모르타르를 타설 후 슬래브에 대해 진동가속도 레벨을 측정한 결과, 84 type 63 Hz에서 CS 모르타르가 66.4 dB, ES 모르타르가 66.1 dB로 일반 모르타르에 비해 2 dB 이상 낮게 나타났다. 또한 철근콘크리트 슬래브 단독과 비교할 때 CS 모르타르가 5.5 dB, ES 모르타르가 4.6 dB이 저감되어 비교적 우수한 값을 보였다. 바닥충격음 음압은 결과의 경우, 84B type이 63 Hz에서 CS 모르타르와 일반 모르타르가 67.3 dB로 유사하게 나타났으며, 철근콘크리트 슬래브 단독 대비 저 감량은 CS 모르타르가 3.6 dB, ES 모르타르가 2.7 dB, 일반 모르타르가 1.4 dB 저감되었다. 철근콘크리트 슬래브의 두께를 보상하기 위하여 모르타르를 타설함으로서 진동가속도레벨 및 바닥충격음은 감소하였으며, 동제련 슬래그 잔골재를 사용한 중량모르타르를 사용할 경우 상대적으로 우수한 성능을 발현하는 것으로 나타났다.

소음 차단 성능 향상을 위한 부틸 탄성체 배합 및 진동제어 시스템 디자인 연구 (Study on the Design of Butyl Rubber Compound and Noise Reduction System for Sound Insulation)

  • 김원택;정경호
    • Elastomers and Composites
    • /
    • 제49권2호
    • /
    • pp.95-102
    • /
    • 2014
  • 최근 공동주택의 층간 소음으로 인하여 사회적 문제가 크게 대두되고 있다. 본 연구에서는 소음 차단 성능을 향상시키기 위해 바닥 진동 제어 시스템에 적용되어질 방진고무를 제조하였다. 다양한 유형의 고무 중 우수한 노화특성, 낮은 반발탄성 및 높은 댐핑특성의 성질은 갖는 부틸 고무를 방진고무의 원료 고무로 선정하였다. 그리고 부틸 컴파운드에 첨가되는 카본블랙의 유형과 함량에 따른 방진고무의 물성을 확인하였다. 표면적이 큰 카본블랙을 사용하거나 함량이 증가할수록 고무와 카본블랙간의 결합고무의 함량이 증가하여 높은 기계적 물성, 낮은 반발탄성과 높은 댐핑특성을 나타내었다. 연구 결과를 토대로 최적의 카본블랙 종류와 함량을 결정하고 방진고무를 제조한 뒤 바닥진동제어 시스템에 적용하였다. 바닥충격음을 측정한 결과 경량충격음 40 dB, 중량충격음 43 dB을 나타내어 소음차단 성능이 우수한 것을 확인할 수 있었다.

다중동조질량감쇠기를 이용한 단순지지 슬래브의 진동 및 소음저감에 관한 연구 (Vibration and Noise Control of the Simply Supported Slab Using the Multi-tuned Mass Damper)

  • 황재승;홍건호;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제18권10호
    • /
    • pp.1006-1013
    • /
    • 2008
  • In this study, it is outlined that heavy weight floor impact noise induced by the vibration of slab can be reduced using multi tuned mass damper(MTMD) effectively. Substructure synthesis is utilized to develope analytical model of the slab coupled with MTMD and acoustic power is introduced to evaluate the performance of noise control for simplicity. Numerical analysis is carried out to investigate the effect of the properties of MTMD on the vibration and noise control of the simply supported slab. Numerical analysis shows that mass ratio of MTMD is critical on the vibration and noise control of the slab and it is also essential to reduce the vibration in higher modes of slab in the light of its great effect on the radiation of sound.

다중질량감쇠기를 이용한 슬래브의 진동 및 소음저감에 관한 연구 (Vibration and noise control of slab using the multi-tuned mass damper)

  • 황재승;김홍진;강경수;홍건호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.659-664
    • /
    • 2008
  • In this study, it is outlined that heavy weight floor impact noise induced by the vibration of slab can be reduced by multi tuned mass damper(MTMD) effectively. Substructure synthesis is utilized to develope analytical model of slab coupled with MTMD and acoustic power is introduced to evaluate the performance of noise control for simplicity. Numerical analysis is carried out to investigate the effect of the properties of MTMD on the vibration and noise control. Numerical analysis shows that mass ratio of MTMD is critical on the vibration and noise control of the slab and it is essential to reduce the vibration in higher modes of slab because it has a great effect on the radiation of sound.

  • PDF

경량골재와 기포제 종류에 따른 경량기포 콘크리트의 물리적 특성 (A Physical Properties of Lightweight Foamed Concrete According to Lightweight Aggregate Types and Foaming agent Types)

  • 김하석;이세현;선정수;김진만
    • 콘크리트학회논문집
    • /
    • 제28권4호
    • /
    • pp.435-444
    • /
    • 2016
  • 층간소음의 문제가 가장 크게 대두되고 있는 현재 층간소음 저감 방법으로 뜬바닥 구조에 적용되는 차음재등이 연구되고 있으나 이러한 방법의 경우 경량충격음에는 효과적이나 중량 충격음을 저감하기에는 재료 및 기술적 한계에 다다르고 있다. 중량충격음 저감을 위해서는 슬래브의 중량을 증가시켜 충격에 대해 바닥은 진동하기 어렵게 하여 충격에 의한 발생음을 저감시키거나, 슬래브의 강성을 높여 충격점의 유효 질량을 높여 중량충격음을 저감하는 것이 필요할 것으로 판단된다. 이에 본 연구에서는 중량 충격음을 저감하기 위한 한 방편으로 고중량, 고강성 기포콘크리트 제조함으로서 바닥충격음을 저감하기 위한 기술을 개발하고자 하였다. 연구 결과 기포제 종류 및 혼입량과 경량골재 종류 및 투입량과 관계없이 유동성은 190 mm이상으로 매우 우수한 것으로 나타났다. 밀도 및 압축강도 측정 결과 기포콘크리트의 경우 기포 혼입율 50%에서만, 경량골재 기포콘크리트의 경우 모든 배합에서 목표 밀도 및 압축강도를 만족하는 것으로 나타났다. 열전도율 측정 결과 기포콘크리트의 경우 VS50을 제외하고는 모두 만족하는 것으로 나타났으며, 경량골재 기포콘크리트의 경우 Type A 골재의 경우 대체율 25%, Type B의 경우 모든 배합에서 목표를 만족하는 것으로 나타났다.

공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교 (Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data)

  • 윤창연;연준오;김명준
    • 한국소음진동공학회논문집
    • /
    • 제24권8호
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

중량충격음 평가방법 변화에 따른 단일수치평가량 기여 주파수 대역 사례 분석 (Case study on frequency bands contributing the single number quantity for heavy-weight impact sound based on assessment method changes)

  • 신혜경;박상희;김경우
    • 한국음향학회지
    • /
    • 제42권6호
    • /
    • pp.565-571
    • /
    • 2023
  • 사후확인제 도입으로 현장에서의 바닥충격음 성능 측정이 의무화되고, 평가 방법이 변경되었다. 제도 변화에 따른 바닥충격음 성능 변화를 추적하기 위해서는 변경된 평가방법에 따라 중량충격음 특성이 어떻게 나타나는지에 대한 연구가 필요하다. 본 연구에서는 평면과 바닥구조가 동일한 하나의 아파트 건물에 위치한 59세대를 대상으로 충격원 및 평가지표에 따라 단일수치평가량을 결정하는 주파수 대역의 기여율을 분석하였다. 단일수치평가량에 따른 주파수대역별 기여도 산출방법이 상이하여 단순 비교는 어려우나, 사후확인제 도입 이전 평가방법(뱅머신 측정 및 L'i,Fmax,AW으로 평가)에서는 63 Hz가 미치는 기여율은 평균 80.8 %로 나타났으며, 125 Hz가 미치는 기여율은 평균 19.2 %으로 나타났다. 현행 평가방법(고무공 측정 및 L'iA,Fmax으로 평가) 에서는 기여율은 50 Hz ~ 80 Hz에서 평균 33.1 %, 100 Hz ~ 160 Hz에서 평균 58.7 %, 200 Hz ~ 315 Hz에서 평균 6.9 %, 400 Hz ~ 630 Hz에서 평균 1.3 %으로, 63 Hz 대역의 기여도가 낮아진 것으로 나타났다. 이 결과는 대상 공동주택에 대한 사례 분석 내용으로, 더 다양한 공동주택에 대한 측정 데이터를 분석할 필요가 있다.

주택성능등급 인정 사례의 부문별 평가 결과 분석 (Analysis on Results evaluated by "Housing Performance Grading System" in Korea)

  • 이성옥
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.55-66
    • /
    • 2010
  • The government is enacted "Housing Performance Grading Indication System" from qualitative housing supply policy and performance of housing under the background of looking for new plan to secure good housing stock and housing performance. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are sound insulation related grading(Light-weight impact sound insulation, heavy-weight floor impact sound insulation, noise emission in bathroom, airborne sound insulation for wall between units), Long-life housing related grading(flexibility, remodeling & maintenance, durability), environment related grading(landscape, indoor air quality and ventilation, energy performance), Living environment related grading(common resident facilities such as playground and consideration for the socially underprivileged such as the aged), Fire fire prevention grading(fire fire prevention). The purpose of this research is to analyze characteristics and assessment results of 20 detailed performance items on "Housing Performance Grading Indication System" which was enforced 240 cases from Jan 9th, 2006 to Sep 30th, 2010. The analysis of approval condition of detailed performance items will be important comments for understanding the current domestic level and development of technology.