• Title/Summary/Keyword: Heavy ion synchrotron

Search Result 4, Processing Time 0.02 seconds

Beam position measurement system at HIRFL-CSRm

  • Min Li ;Guoqing Xiao ;Ruishi Mao ;Tiecheng Zhao ;Youjin Yuan ;Weilong Li ;Kai Zhou;Xincai Kang;Peng Li ;Juan Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1332-1341
    • /
    • 2023
  • Beam position measurement system can not only provide the beam position monitoring, but also be used for global orbit correction to reduce beam loss risk and maximize acceptance. The Beam Position Monitors (BPM) are installed along the synchrotron to acquire beam position with the front-end electronics and data acquisition system (DAQ). To realize high precision orbit measurement in the main heavy ion synchrotron and cooling storage ring of heavy-ion research facility in Lanzhou (HIRFL-CSRm), a series of alignment and calibration work has been implemented on the BPM and its DAQ system. This paper analyzed the tests performed in the laboratory as well as with beam based on the developed algorithms and hardware. Several filtering algorithms were designed and implemented on the acquired BPM raw data, then the beam position and resolution were calculated and analyzed. The results show that the position precision was significantly improved from more than 100 ㎛ to about 50 ㎛ by implementing the new designed filtering algorithm. According to the analyzation of the measurement results and upcoming physical requirements, further upgrade scheme for the BPM DAQ system of CSRm based on field programmable gate array (FPGA) technology was proposed and discussed.

Room Temperature Ferromagnetism on Co and Fe Doped Multi-wall Carbon Nano-tube

  • Chae, K.H.;Gautam, S.;Yu, B.Y.;Song, J.H.;Augustine, S.;Kang, J.K.;Asokan, K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.171-171
    • /
    • 2011
  • Co and Fe doped multi-wall carbon nano-tubes (MWCNTs) synthesized by microwave plasma enhanced chemical vapor deposition (PECVD) technique are investigated with synchrotron radiations at Pohang Light Source (PAL) and European Synchrotron Radiation Facility (ESRF). Near edge x-ray absorption spectroscopy (NEXAFS) measurement at C K, Co $L_{3,2}$ and Fe $L_{3,2}$-edges, and x-ray magnetic circular dichroism (XMCD) at Co and Fe $L_{3,2}$-edges have been carried at 7B1 XAS KIST and 2A MS beamline, respectively, to understand the electronic structure and responsible magnetic interactions at room temperature. X-ray absorption spectroscopy (XAS) at C K-edge shows significant p-bonding and Co and Fe L-edges proves the presence of $Co^{2+}$ and $Fe^{2+}$ in octahedral symmetry. Co and Fe doped MWCNTs show good XMCD spectra at 300K. The effect on the magnetism is also studied through swift heavy ion (SHI) radiations and magnetism is found enhanced and change in the electronic structure in Co-CNTs is investigated.

  • PDF

A Study on the Difference of Geometrical Modeling in the Calculation of Shielding and Activation Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 차폐 및 방사화 계산에서 기하학적 모델링의 차이에 따른 결과 연구)

  • Heo, Seunguk;Song, Yongkeun;Cho, Gyuseok;Han, Moojae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.429-435
    • /
    • 2017
  • In order to increase the therapeutic effect of radiation, there has been an increase in the use of conventional photon therapy. The intensive care unit should pay more attention to the radiation safety evaluation due to the higher energy and the larger facility compared to the existing Photon treatment. These radiation safety evaluations are mainly performed by using Monte Carlo simulation, and the first thing to be done is geometric modeling. The Heavy-ion treatment facility uses synchrotron as the accelerating device, which is difficult to precisely model geometrically and is mostly modeled briefly. This study investigated the effect of simplification and precise implementation of Dipole magnet among the components of synchrotron acceleration device on the radiation safety evaluation. The results show that the simplified geometric model is overestimated with the precisely implemented geometric model. Therefore, it is considered that the radiological safety evaluation results in more reliable results of the precise geometric modeling.

XAS Studies of Ion Irradaited MgO Thin Films

  • Suk, Jae-Kwon;Gautam, Sanjeev;Song, Jin-Ho;Lee, Jae-Yong;Kim, Jae-Yeoul;Kim, Joon-Kon;Song, Jong-Han;Chae, Keun-Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.312-312
    • /
    • 2012
  • Magnesium oxide has become focus for research activities due to its use in magnetic tunnel junctions and for understanding of do ferromagnetism. Theoretical investigations on such type of system indicate that the presence of defects greater than a threshold value is responsible for the magnetic behaviour. It has also been shown experimentally that by decreasing the film thickness and size of nanoparticles, enhancement/increase in magnetization can be achieved. Apart from the change in dimension, swift heavy ions (SHI) are well known for creating defects and modifying the properties of the materials. In the present work, we have studied the irradiation induced effects in magnesium oxide thin film deposited on quartz substrate via X-ray absorption spectroscopy (XAS). Magnesium oxide thin films of thickness 50nm were deposited on quartz substrate by using e-beam evaporation method. These films were irradiated by 200 MeV Ag15+ ion beam at fluence of $1{\times}10^{11}$, $5{\times}10^{11}$, $1{\times}10^{12}$, $3{\times}10^{12}$ and $5{\times}10^{12}ions/cm^2$ at Nuclear Science Centre, IUAC, New Delhi (India). The grain size was observed (as studied by AFM) to be decreased from 37 nm (pristine film) to 23 nm ($1{\times}10^{12}ions/cm^2$) and thereafter it increases upto a fluence of $5{\times}10^{12}ions/cm^2$. The electronic structure of the system has been investigated by X-ray absorption spectroscopy (XAS) measurements performed at the high energy spherical grating monochromator 20A1 XAS (HSGM) beamline in the National Synchrotron Radiation Research Center (NSRRC), Taiwan. Oxides of light elements like MgO/ZnO possess many unique physical properties with potentials for novel application in various fields. These irradiated thin films are also studied with different polarization (left and right circularly polarized) of incident x-ray beam at 05B3 EPU- Soft x-ray scattering beamline of NSRRC. The detailed analysis of observed results in the wake of existing theories is discussed.

  • PDF