Abstract
In order to increase the therapeutic effect of radiation, there has been an increase in the use of conventional photon therapy. The intensive care unit should pay more attention to the radiation safety evaluation due to the higher energy and the larger facility compared to the existing Photon treatment. These radiation safety evaluations are mainly performed by using Monte Carlo simulation, and the first thing to be done is geometric modeling. The Heavy-ion treatment facility uses synchrotron as the accelerating device, which is difficult to precisely model geometrically and is mostly modeled briefly. This study investigated the effect of simplification and precise implementation of Dipole magnet among the components of synchrotron acceleration device on the radiation safety evaluation. The results show that the simplified geometric model is overestimated with the precisely implemented geometric model. Therefore, it is considered that the radiological safety evaluation results in more reliable results of the precise geometric modeling.
방사선의 치료효과 증대를 위해 최근에는 기존의 Photon치료를 대체한 중입자치료가 증가하고 있다. 중입자 치료는 기존 Photon치료 대비 높은 에너지와 거대한 시설로 인해 방사선안전성평가에 더욱 신경을 써야 한다. 이러한 방사선안전성평가는 주로 Monte Carlo simulation을 이용하여 차폐 및 방사화 평가를 수행하는데, 가장 우선적으로 수행해야하는 것은 기하학적 모델링이다. 중입자 치료시설은 가속장치를 싱크로트론을 사용하게 되는데 정확한 기하학적 모델링이 어려워 대부분 간략하게 모델링 한다. 본 연구는 싱크로트론 가속장치의 구성요소 중에서 Dipole magnet을 간략화 한 것과 정밀하게 구현한 것이 방사선안전성 평가에 어떠한 영향을 미치는지 알아보았다. 결과에 의하면 간략하게 구현한 기하학적 모델이 정밀하게 구현된 기하학적 모델보다 과대평과 되는 결과를 얻었다. 따라서 방사선안전성평가는 정밀한 기하하적 모델링이 더욱 신뢰할 수 있는 결과를 얻는다고 판단된다.