• 제목/요약/키워드: Heating-cooling

검색결과 2,022건 처리시간 0.035초

전북지역 초중고등학교 학교급식소의 내부시설 및 위생관리 실태 조사 (Survey on Internal Facilities and Sanitary Management of Elementary, Middle, and High School Foodservice in Chonbuk Area of Korea)

  • 국숙자;노정옥
    • 한국생활과학회지
    • /
    • 제18권5호
    • /
    • pp.1135-1145
    • /
    • 2009
  • This study was conducted to investigate the situation of internal facilities and sanitary management of elementary, middle, and high school foodservice in Chonbuk area. Self administered questionnaires were collected from 252 nutrition teachers and school dietitians. Statistical data analysis was completed using a SPSS 11.5 program. The results are summarized as follows: Approximately 99.2% of the subjects were women and those who were married accounted for 76.6%. Those in their 30s to 40s accounted for over 87%, those with more than 11 years experience accounted for 56.8%, and those 69.0% were regular nutrition teachers. Among the 280 school foodservice systems, 51.6% of the schools were located in urban areas and 48.0% in rural areas. About 68% of the schools prepared meals the conventional way and 32.3% prepared them the commissary way. The number of employees accounted for in the schools was 37.7% with 1 to 3 employees, 27.8% with 4 to 6 employees, and 25.4% with 7 to 9 employees. About 54% of schools have an expectance of school meal service for more than 11 years. However 67.5% of their facilities had not been remodeled since the implementation of the foodservice. As a result of the conditions of the school foodservice facilities, there were significant differences between elementary and middle & high schools; preparation room (p<0.01), toilet (p<0.01), and boiler room (p<0.01). About 62% of the nutrition teachers responded that they were dissatisfied with the situation of the facilities (e.g. size and materials of the kitchen, heating and cooling systems). The washing and disinfection methods in elementary, middle and high schools were very different, because they had no sanitizers and disinfectant guidelines. Therefore the governmental regulating agencies must review and approve of the plans prior to new construction or extensive remodeling of the school foodservice facilities. In addition, we suggest that it is necessary to provide practical sanitizers and disinfectant guidelines and other useful education.

리튬이온 배터리의 열관리가 전기자동차 주행거리에 미치는 영향 (Effect of Thermal Management of Lithium-Ion Battery on Driving Range of Electric Vehicle)

  • 박철은;유세웅;정영환;김기범
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.22-28
    • /
    • 2017
  • 전기자동차에 사용되는 리튬이온 배터리의 성능은 배터리 온도에 따라 큰 차이를 보인다. 본 논문에서는 유한차분법을 이용하여 배터리의 발열량에 따른 배터리의 온도변화를 평가하고, 배터리의 충전량, 내부저항 및 전압변화를 조사하였다. 이 배터리 모델을 1차원 해석 프로그램인 AMESim과 연동하여 전기자동차가 NEDC 모드로 주행 시, 배터리의 온도 변화에 따른 전기자동차의 주행거리를 산출하였다. 배터리는 온도가 $25^{\circ}C$ 이하로 감소하면 내부저항이 증가하기 때문에 발열량이 증가하여 주행거리는 줄었다. 또한, 배터리의 온도가 $25^{\circ}C$ 이상이 되면, 배터리의 충전량이 감소하여 배터리의 성능이 떨어지고 그 결과로 주행거리가 줄었다. 배터리의 성능을 최적으로 유지할 수 있는 온도인 $25^{\circ}C$를 기준으로 배터리의 온도가 $-20^{\circ}C$$45^{\circ}C$일 때, 전기자동차의 주행거리는 각각 33%와 1.8% 감소하였다. 배터리의 최적 온도를 유지하기 위해 효율적인 배터리 열관리를 통하여 저온에서는 가열, 고온에서는 냉각이 이루어져야 한다. 해석 결과 외기온이 $-20^{\circ}C$인 경우 500 W의 열을 공급해주어야 하며, 외기온이 $45^{\circ}C$ 경우에는 냉방을 통해 250 W의 열을 방출해줌으로써 배터리 구동의 최적 온도인 $25^{\circ}C$를 유지할 수 있다.

수종해조의 단백계수와 in vitro Digestibility (Nitrogen Conversion Factors and in vitro Protein Digestibility of some Seaweeds)

  • 류홍수;;이강호
    • 한국수산과학회지
    • /
    • 제15권4호
    • /
    • pp.263-270
    • /
    • 1982
  • 해중의 영양학적인 기초자료를 얻기 위하여 multi-enzyme system을 이용한 체외소화율과 아미노산분석을 기초로 한 단백질수를 측정하였다. 김 (P. tenera)의 체외소화율은 $78.5\sim82.2$로서 산지와 건조조건에 따라 약간의 차이를 보였으며, 잎파래(E. linza)나 다른 갈조류 (미역 U. pinnatifida, 톳 H. fusiforme, 모자반 S. fuuellum)에 비하여 높았고 효소활성 저해물질 (trypsin inhibitor)의 함량은 갈조류에서 높았다. 잎과래는 채외소화율이 김보다 낮음에도 불구하고 효소활성저해물질이 가장 낮은 특이한 결과론 보였다. 전체적으로 해조류의 체의소화을이 다른 연구자들의 생체실험에 의한 소화율 (in vivo digestility)보다 높은 결과를 보인 것은multi-enzyme system을 이용한 체외소화율 측정 방법을 해조류의 정확한 소화율 측정에 적용하기에는 문제성이 있는 것으로 밝혀졌다. 일륜 김에 대한 microwave cooking의 영향은 가열시간이 15분 경과하여도 현저한 소화율 증가는 볼 수 없었으며, 효소활성 저해물질함량은 서서히 감소하는 경향을 보였다. 또한 한국식으로 구운김의 체외소화율은 microwave로 15분 가열한 시료와 비슷하였다. 아미노산 분석 결과를 이용한 단백계수(Factor method)는 김의 경우 6.52로 계산되었고, 잎파래는 6.00, 미역 6.11, 모자반 5.85, 톳은 5.83이었으며, Kjeldahl전소분석결과를 이용한 단백계수(Kjeldahl Method)는 김 6.29, 잎파래 5.83, 미역 5.40, 모자반 5.45, 톳 5.49로 나타나, 종래의 조단백계수(6.25)보다 낮은 결과를 보였다. 해조추의 비단백태질소의 정확한 규명이 없는 상태에서, 해조의 단백질함량 측정에는 아미노산 분석결과를 이용한 새로운 단백계수(Factor Method)를 사용함이 바람직한 것으로 생각되었다.

  • PDF

HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가 (Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents)

  • 윤철;박진희;황미정;한상훈
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.553-562
    • /
    • 2012
  • 난방, 환기 및 공기조절(HVAC) 기능이 상실된 사고의 경우, 보조급수를 위한 모터-구동 펌프격실의 온도상승을 전산유체역학 분석을 통해 평가하였다. 닫힌 펌프격실의 과도 계산결과, 8 시간 동안 공간-평균된 공기온도는 $60^{\circ}C$ 정도의 상승이 예상된다. 외기 온도 및 외부 온도는 이전 계산결과로부터 초기 $35^{\circ}C$에서 시작하여 서서히 증가한다고 가정하였다. 격실 문이 사고발생 후 약 2, 4, 그리고 6시간 경과 시점에서 열릴 경우, 체적-평균 격실 내가 온도는 약 $4^{\circ}C$의 즉각적인 하강이 나타나며 이후 서서히 온도가 상승하는 장기 거동을 보인다. 전산유체역학을 적용한 현재의 상세 해석결과는 이전의 집중(lumped) 모델을 사용한 보수적인 계산결과에 비해 낮은 격실온도 상승률을 예측한다.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제25권1호
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

공공의료시설에 적합한 신재생에너지시스템의 복합적용비율에 관한 연구 (A Study on the Application Ratio by the New and Renewable Energy Systems Fit for Public Medical Facilities)

  • 홍준호;이용호;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.32-43
    • /
    • 2014
  • This study set out to identify the importance of each factor influencing facility selection with a survey among public medical facilities under the category of public buildings and apply the importance of economy, technology and environment with the weighting factor method, thus proposing optimal application plans. The research content of each section can be summarized as follows:1) Estimated energy consumption according to the energy simulation was 65,129MWh/yr, which was 18.7% higher than that according to the calculation equation. Of the energy consumption, more than 80% was used by heating and cooling facilities and construction facilities, and 20% was used by electronics such as medical equipments and in and outdoor lighting. 2) The results of a survey on the factors influencing the importance when selecting a new and renewable energy system reveal that the upper items had a priority in economy, environment, and technology in the descending order and that the lower item shad a priority in initial investments, maintenance and repair costs=energy costs, supply reliability, energy efficiency and $CO_2$ emissions in the descending order. 3) The application alternatives were analyzed in economy, technology, and environment. As a result, a geothermal system turned out to be the most excellent one a cross all the upper and lower comparison items. Of the other systems, a solar thermal system was superior in initial investments, maintenance and repair costs, and energy efficiency, where as a photovoltaic system was superior in energy costs, supply reliability, and $CO_2$ emissions. 4) As for the mixed application ratio among economy, technology, and environment, when the percentage of a geothermal system was approximately 80% or higher in anew and renewable energy system, it was the best and most optimal application plan.

Nd:YAG 레이저에 의한 다층 박막의 미소 점 마킹 (Spot marking of the multilayer thin films by Nd:YAG laser)

  • 김현진;신용진
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.361-368
    • /
    • 2004
  • 콤팩트디스크(CD-R; Compact DiskRecordable)를 성분별로 분리하여 제작하고, 다층 박막 구조를 만들어서 레이저빔의 에너지를 변화시켜 가면서 조사하여 각 성분 층에서의 최적 미소 점 마킹 조건과 홈 형성 과정에 관하여 연구하였다. 본 연구는 Q-스위치 Nd:YAG 레이저를 이용하여 준비된 각 시료의 표면에 27∼373 mJ 빔을 80 $\mu\textrm{m}$의 점적 크기로 조사하여 샘플에 형성된 흠 형태를 광학현미경(OM; Optical Microscope)과 광 결맞음 단층촬영기(OCT; Optical Coherence Tomography)로 비교-관찰하여 미소 점 마킹의 형성 과정을 분석하였다. 다층 박막에서 용융된 기판 층은 짧은 시간동안 충분한 열 흐름이 발생하여 증배의 형성을 야기하며, 반사 층과 염료 층 사이에 흡수된 에너지는 염료를 용융시키고 체적을 증가시켰으며, 증배가 식으면서 표면장력의 영향 및 레이저빔에 의한 순간적인 시편의 온도상승으로 기화와 반동압력에 의한 질량흐름 때문에 두 층의 경계면에서 홈과 외륜의 발생을 설명할 수 있었다. 따라서 다층 박막에서의 미소 점 마킹의 형성 과정은 표면장력, 용융 점성력, 층 두께, 다층 박막 성분 물질의 물리화학적ㆍ광학적 성질과 관계가 있음을 알 수 있었다.

초기 양생조건에 따른 고강도 콘크리트의 강도발현에 관한 실험적 연구 (An Experimental Study on the Strength Development of High Strength Concrete in Various Curing Conditions at an Early-age)

  • 권영호;이태왕
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.141-148
    • /
    • 2017
  • 본 연구는 PC부재의 공장생산에 있어서 여러 가지 증기양생 조건의 변수에 따른 고강도 콘크리트의 초기 압축강도 발현성상을 실험적으로 검증하고, 최적 양생조건을 확인하기 위한 것이다. 40 MPa 이상의 고강도 콘크리트 제조에는 보통 포틀랜드 시멘트를 사용하였으며, 콘크리트의 배합조건은 물-시멘트비 3종류(W/C 25%, 35% 및 45%)를 대상으로 하였다. 본 연구의 증기양생 변수로 (1) 전치양생 시간 3종류, (2) 최고 양생온도 3종류, (3) 최고온도 유지시간 3종류, (4) 승온 및 강온양생 온도 1종류 등을 대상으로 재령별 압축강도 시험을 실시하였다. 또한, 증기양생 및 표준양생에 따른 재령별 강도발현을 비교하였다. 실험결과, (1) 전치양생은 콘크리트의 초기 응결시간 이상, (2) 최고 양생온도는 $55^{\circ}C$ 이하, (3) 최고온도 유지시간은 6시간 이하로 하는 것이 증기양생 고강도 콘크리트의 강도발현에 적합한 양생조건으로 나타났다. 또한, 재령 28일에서 증기양생과 표준양생의 압축강도 발현성상의 역전현상이 발생하였다. 따라서 이러한 양생조건으로 PC부재의 생산성 및 현장관리를 위한 기초자료로 제시하고자 한다.

병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가 (Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile)

  • 박상우;김병연;성치훈;최항석
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.361-375
    • /
    • 2015
  • 에너지파일은 기존의 수직밀폐형 지중열교환기를 경제적으로 대체할 수 있는 새로운 형태의 지중열교환기이다. 즉, 에너지파일은 건물의 기초 구조물과 지중열교환기의 역할을 동시에 수행하는 에너지 구조체로서, 말뚝 기초 내부에 열교환 파이프를 삽입하고 파이프를 통해 유체를 순환시켜 지반과의 열교환을 유도한다. 본 연구에서는 병렬 U형(5쌍, 8쌍, 10쌍)의 열교환 파이프를 대구경 현장타설 에너지파일에 삽입하여, 3본의 에너지파일을 실규모로 시공하였다. 또한 현장 열응답 시험(In-situ thermal response tests, TRTs)을 수행하고 시공된 현장타설 에너지파일과의 열교환 효율을 비교하기 위하여 30m 깊이의 수직밀폐형 지중열교환기를 별도로 시공하였다. 병렬 U형 현장타설 에너지파일에 대해서는 냉난방 부하를 인공적으로 주입하는 열교환 성능 평가시험을 수행하여 열교환 성능(heat exchange rate)을 평가하였다. 마지막으로 현장타설 에너지파일의 적용성 평가를 위해 산정된 상대 열교환 효율(relative heat exchange efficiency) 및 열교환 성능을 선행 연구 결과와 비교하였으며, 본 연구에서 시공된 현장타설 에너지파일은 안정적이고 효율적인 열성능을 보이는 것으로 나타났다.

레이저 열원을 이용한 보론강 및 핫스탬핑강의 용접특성에 관한 연구 (I) - 핫스탬핑 공정에 사용되는 Al-Si 코팅된 보론강의 레이저 용접특성 - (The Study on Weldability of Boron Steel and Hot-Stamped Steel by Using Laser Heat Source (I) - Laser Weldability of Al-Si Coated Boron Steel Used for Hot Stamping Process -)

  • 김종도;최소영;이수진;서정
    • 대한기계학회논문집A
    • /
    • 제38권12호
    • /
    • pp.1367-1372
    • /
    • 2014
  • 전세계적으로 환경문제에 대한 위기의식이 고조됨에 따라 운송산업 분야에서는 차체경량화를 통해 이와 같은 문제를 해결하고자 하였다. 차체경량화의 방법으로써 보론강을 $900^{\circ}C$이상의 온도에서 가열한 후, 성형과 동시에 냉각하여 1500 MPa 이상의 강도를 얻을 수 있는 핫스탬핑 공정이 제시되고 있다. 하지만 핫스탬핑 공정에 일반적으로 사용되고 있는 보론강의 레이저 용접성에 대한 연구결과는 많지 않다. 따라서 본 연구에서는 보론강의 레이저 용접특성을 조사하기 위해 레이저 매개변수에 대하여 기초적 연구를 실시하였다. 실험결과, 실드가스에 대한 매개변수의 최적의 조건은 $Q=20{\ell}/min$, ${\alpha}=40^{\circ}$, d = 20 mm, l = 0 mm이며, 맞대기 용접부의 경도는 용접부에서 마르텐사이트 형성으로 인해 급격하게 상승하였다.