• 제목/요약/키워드: Heating sheet

검색결과 220건 처리시간 0.03초

HNx 분위기가스중에서 BAF소둔시 코일의 온도변화에 관한 연구 (A Study on Temperature Variation of Coil on BAF Annealing in HNx Atmospheric Gas)

  • 전언찬;김순경
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1227-1234
    • /
    • 1994
  • A cold spot temperature control system for the batch annealing furnace has been established in order to reduce energy consumption which is essential to improve productivity and stabilize the properties of products. A relationship between annealing cycle time and gas flow rate is developed and also for the variation of coil cold spot temperature with time during heating, and actual temperature measurements at mid-width of each coil during soaking. The results of the temperature variation effect on the cold rolled steel sheet batch annealing are as follows. (1) Cooling rate increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component change. (2) In case of short time heating, the slowest heating part is the center of B coil and in case of ling time heating, the low temperature point moves from the center of coil to inside coil. (3) The outside of top coil is the highest temperature point under heating, which becomes the lowest temperature point under cooling. (4) Soaking time determination depends on the input coil width, and soaking time for quality homogenization of 1214 mm width coil must be 2 hours longer than that of 914 mm width coil.

고주파 유도가열을 이용한 열간 파이프 벤딩 공정 설계 (Process Design of the Hot Pipe Bending Process Using High Frequency Induction Heating)

  • 류경희;이동주;김동진;김병민;김광호
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.110-121
    • /
    • 2001
  • During hot pipe bending using induction heating, the wall of bending outside is thinned by tensile stress. In design requirement, the reduction of wall thickness is not allowed to exceed 12.5%. So in this study, two methods of bending, one is loading of reverse moment and the other is loading of temperature gradient, have been investigated to design pipe bending process that satisfy design requirements. For this purpose, finite element analysis with a bending radius 2Do(outer diameter of pipe) has been performed to calculate proper reverse moment and temperature gradient to be applied. Induction heating process has been analyzed to estimate influence of heating process parameters on heating characteristic by finite difference method. Then pipe bending experiments have been performed for verification of finite element and finite difference analysis results. Experimental results are in good agreement with the results of simulations.

  • PDF

고주파유도가열에 의한 고강도 센터필라 개발 (Development of High Strength Center-pillar by High Frequency Induction Heating)

  • 손진혁;염영진;김원혁;황정복;김선웅;유승조;이현우
    • 대한기계학회논문집A
    • /
    • 제32권6호
    • /
    • pp.533-539
    • /
    • 2008
  • An high frequency induction hardening technology of vehicle body press-formed of thin sheet steel has been developed to increase the strength of vehicle body parts locally by high frequency induction heating, thereby eliminating the need for reinforcements. And this technique for increasing the tensile strength of sheet steel was practically applied to the front floor cross member and center pillar reinforcement of a passenger car. The side impact behavior has been investigated when induction hardening technology is applied to the conventional low-carbon steel and weight reduction of an automotive body is expected. In this paper, basic experiments were performed for the hat-shaped specimen under high frequency induction heating process. Martensitic transformation was found in the heating zone through microscopic observation which showed higher hardness. In addition, the hardness and strength of the center-pillar specimen made of boron steel increased remarkably by high frequency induction heating.

로이유리의 전도성 금속박막을 이용한 발열유리 제작에 관한 연구 (A study on the fabrication of heatable glass using conductive metal thin film on Low-e glass)

  • 오재곤
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.105-112
    • /
    • 2018
  • 본 논문은 로이유리(Low emissivity glass) 표면에 증착되어 있는 금속박막의 전도 특성을 이용하여 발열유리(Heatable glass)를 제작하는 방법에 대해 제안한다. 로이유리의 발열량은 로이유리 표면저항에 의한 주울(Joule) 열에 의존하므로 소재의 표면저항을 측정함으로써 예측 및 설계가 가능하다. 본 연구에서는 저방사층이 11nm인 소프트로이유리 시료에 각 50mm 간격으로 은(Ag) 전극을 형성시키고, 4단자법으로 면저항을 측정하여 로이유리의 소비전력과 발열량을 예측한 후에, 제작 및 실험을 통해 발열성능을 확인하였다. 기존의 발열유리 제작방법은 크게 두 가지로 일반유리(Normal glass)에 니크롬(Nichrome) 열선을 삽입하는 방법과, 일반유리에 전도성 투명박막을 증착하는 방법이 있다. 니크롬 열선 삽입 방식은 발열성능은 우수하나 유리 고유의 투명성을 저해하고, 전도성 투명박막을 증착하는 방법은 투명성은 양호하나 공정이 복잡하여 실용성이 저하된다. 본 논문에서는 주로 건축물의 단열효과 향상을 위해 사용되는 로이유리를 이용하여 로이유리 전면에 코팅되어 있는 전도성 금속박막에 레이저 빔을 조사하여 원하는 발열성능을 가지는 발열유리를 제작하는 방법을 제안한다. 제안된 방법은 기존의 니크롬 열선을 삽입하는 방법에 비해 투명성이 양호하고, 전도성 투명박막을 증착하는 방법에 비해 제작과정이 보다 수월함을 확인하였다. 아울러, 레이저를 조사하여 로이유리의 표면 박막을 패터닝(Patterning) 하는 형태에 따른 발열특성의 비교와 로이유리에 적합한 레이저 출력조건을 제시하고자 한다.

복합보온양생 방법이 극저온 조건하 플라이애시 치환 콘크리트의 온도이력에 미치는 영향 (The Effect of Heat Curing Methods on the Temperature History of the Fly Ash Concrete Subjected to Extremely Low Temperature)

  • 한민철;손호정
    • 한국건설순환자원학회논문집
    • /
    • 제7권3호
    • /
    • pp.85-90
    • /
    • 2012
  • In this study, temperature profile of the fly ash concrete were studied in accordance with the change of heating curing method combination for the slab concrete in order to develop efficient protection method of the concrete subjected to $-20^{\circ}C$. The slab concretes with the size of $1200mm{\times}600mm{\times}200mm$ were fabricated with W/B of 50% and exposed to $-20^{\circ}C$ for 7 days. Five different combinations of heat curing methods were applied to the slab concrete specimen; two combinations of heat supplying by electrical heater and surface heat insulation material such as polyethylene film and quadrupled layer bubble sheet based on heat enclosure installment; three combinations of heating coil embedment and surface heat insulation materials such as polyethylene film, sawdust and quadrupled layer bubble sheet based on heat enclosure installment. Test results showed that by applying both heating coil and bubble sheet and heat enclosure, the concrete exposed to $-20^{\circ}C$ can be effectively protected from early-age frost damage.

  • PDF

박판 인장 시험에서 가공열의 영향에 관한 유한요소 해석 (A Finite Element Analysis of Deformation-Induced Heating in Tensile Testing of Sheet Metals)

  • 김용환
    • 대한기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.680-688
    • /
    • 1989
  • 본 연구의 목적은 2차원 유한요소법을 이용하여 변형과 열전달의 복합된 열소성 문제를 해석하여 재료의 성형성에 대한 가공열의 영향을 연구하는 것이다. 2차원 해석은 종래 단순 인장시험의 해석에 사용되던 1차원 해석에 비해 보다 정확한 해를 가지며 특히 넥킹의 발생 이후의 해석에 유용하다.

고주파 유도가열 장치를 이용한 알루미늄 박판 점착 복합방수시트 조인트부의 시공성 (Constructability of a Waterproofing Sheet Joint Combining an Aluminum Thin-film and Viscosity Layer Using a High-frequency Inductive Heating Apparatus)

  • 장상묵;김윤호;최성민
    • 한국건축시공학회지
    • /
    • 제14권2호
    • /
    • pp.163-169
    • /
    • 2014
  • Engineers in the construction field have been using bonded waterproofing sheets in an attempt to resolve the imbalance in the quality, the risk of fire, safety of workers, and environmental pollution, as well as to eliminate separate use of organic adhesives on the surface of concrete. Recently, self-laminated waterproofing sheets have been developed. The purpose of this research is to find an appropriate processing speed according to the changes in physical properties, and visual observation of the waterproofing sheets laminated by the aluminum thin-film and viscosity layer that can be attached through self-adhesiveness on the surface of concrete and waterproofing sheets. Therefore, this research is conducted using a physical performance test. Based on the result of the test, when the high-frequency inductive heating apparatus was used, an improved adhesion and bonding stability effect were confirmed after the anti-hydrostatic pressure and bond strength in the temperature condition, and the surface observation in the processing speed condition.

Simple modeling to explore temperatures, heated temperature, and Kappa values of a current sheet observation

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Shen, Chengcai;Kahler, Stephen;Moon, Yong-Jae;Kim, Yeon-Han
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.79.2-79.2
    • /
    • 2021
  • We explore the range of possibilities of temperatures, heated temperature, and Kappa values of a current sheet observation on 2017 September 10. First, we construct a grid model with rapid heating (Theat) and various Kappa (κ) values. We assume a simple density model and use adiabatic cooling to set the temperature during expansion. Next, we calculate the ion fractions using a time-dependent ionization model with adiabatic cooling and various Kappa values. The calculated ion fractions are used to simulate the DNs of the Atmospheric Imaging Assembly on board the Solar Dynamic Observatory. Then, we explore the possible range of the temperatures and Kappa values, comparing the simulated images with the observations. Finally, we discuss the range of the heated temperature and Kappa values and whether the result of this study suggests continuous heating of the current sheet plasma during the expansion.

  • PDF

AKD 사이즈 처리한 종이의 저장중 가열처리에 의한 AKD의 거동 (Behavior of AKD in AKD-sized Paper by Heating Treatment During Ageing)

  • 신영두;서원성;조남석
    • 펄프종이기술
    • /
    • 제39권1호
    • /
    • pp.16-24
    • /
    • 2007
  • This study was performed to investigate the reaction between alkylketene dimer(AKD) and cellulose molecules in AKD-sized paper sheet. AKD was added to highly beaten($80{\pm}3^{\circ}SR$) SwBKP(ca. 0.8% on pulp) in order to have much AKD retention in the paper sheet. This AKD-sized paper sheet was aged at different temperatures, $60^{\circ}C,\;80^{\circ}C,\;105^{\circ}C\;and\;125^{\circ}C$. Changes in FT-IR spectra of AKD in paper sheet during the ageing were measured. In addition, sizing degrees of the AKD-sized paper sheet pretreated for 30 sec. at $105^{\circ}C$ were measured by HST size tester during the storage at different temperature. IR spectra of AKD-sized paper sheet preheated at $105^{\circ}C$ for 30 sec. showed unchanged spectra two absorption bands at $1849cm^{-1}\;and\;1722cm^{-1}$ which refer to the typical AKD IR bands. However, these typical AKD bands were gradually reduced with increasing ageing, completely disappeared after 6 hrs. and formed new absorption band at $1706cm^{-1}$, which refers to carbonyl stretching vibration of dialkylktone. Eventually the AKD molecule was hydrolyzed to diakylketone without formation of ${\beta}$-ketoester with cellulose in paper sheet. After 6 days ageing, a little amount of ${\beta}$-ketoester bands was identified in 6 or 7 days ageing, because of the absence of water due to long-term heating. The same tendency was observed at different ageing conditions. At the practical papermaking process, AKD reacts prevailing with water, and mostly seems to be hydrolyzed to dialkylketene. Concerned to the sizing development, AKD-sized paper sheet was shown no sizing development at the initial stage of ageing at $60^{\circ}C$ after heating treatment at $105^{\circ}C$ for 30 sec., and gradually increased the sizing degree with increasing ageing, such as Hercules Sizing Tester (HST) 130 see for 12 hr, HST 300 sec. for 3 days and HST 400 sec. for 5 days. It was concluded that hydrolyzed AKD could contributed to the sizing development of the paper sheet.

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.