• Title/Summary/Keyword: Heating ratio

Search Result 957, Processing Time 0.032 seconds

A Study on the Fundamental Properties and Application as Cementious Admixture by Heating Temperature of Recycled Powder (재생미분말의 가열온도에 따른 기초물성 및 시멘트혼화재 적용성에 관한 연구)

  • 장종호;김용로;최세진;최희용;김문한;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.635-640
    • /
    • 2001
  • Recently, it has been processed to study about recycled aggregate but a study about using of recycled powder is producted when manufacturing recycled aggregate has not been acted. So in this study on the fundamental properties and application as cementious admixture by heating temperature for mortar properties of recycled powder and sand is obtained like following results. It is judged that application of recycled powder of heat treatment on $600^{\circ}C$ and cement replacement ratio below 10% is available.

  • PDF

Densification and rain Growth of Alumina Heated by Microwave (Microwave로 가열한 알루미나의 소결 및 입성장 거동)

  • 김도형;오성록;김종희
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.4
    • /
    • pp.305-311
    • /
    • 1992
  • As compared with conventional sintering, rapid heating in microwave system could enhance sinterability and final properties of alumina with a very short sintering time. In this study microwave sintering was performed using zirconia brick as a reaction chamber which was positioned in a 2.45 GHz(700 W) multimode microwave cavity. Microwave-sintered alumina showed high density and smaller grain size than conventionally sintered alumina because the ratio of densification rate/grain growth rate was increased by rapid heating.

  • PDF

Analytic Design of a Ferroresonant Transformer for Microwave Heating System (초고주파 가열장치에 사용하는 철공진 변압기의 해석적 설계)

  • 나정웅;김원수
    • 전기의세계
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 1979
  • In the microwave heating system, a ferroresonant transformer is used to regulate the magnetron power fluctuation. For the simplification, nonlinear characteristics of the transformer and the magnetron are idealized to be piecewise linear. Dipped peak shape of the magnetron current is explained qualitatively by considering the fundamental and third harmonic frequency components in the circuit. Design equations providing the values of the leakage inductance, turn ratio of the transformer and the capacitance are derived analytically by cosnidering the fundamental frequency component only. The ferroresonant transformer is designed to obtain a required regulation and high input power factor from the derived design equations, and analytical calculations are compared with experimental measurements.

  • PDF

Study on the Heating Performance Characteristics of a Heat Pump System Utilizing Air and Waste Heat Source for Electric Vehicles (이중열원을 이용한 전기자동차용 히트펌프 시스템의 난방 성능 특성에 관한 연구)

  • Woo, Hyoung Suk;Ahn, Jae Hwan;Oh, Myoung Su;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.180-186
    • /
    • 2013
  • An electric vehicle is an environment-friendly automobile which does not emit any tailpipe pollutant. In a conventional vehicle with an internal combustion engine, the internal cabin of the vehicle is usually heated using waste heat from the engine. However, for an electric vehicle, an alternative solution for heating is required because it does not have a combustion engine. Recently, a heat pump system which is widely used for residential heating due to its higher efficiency has been studied for its use as a heating system in electric vehicles. In this study, a heat pump system utilizing air source and waste heat source from electric devices was investigated experimentally. The performance of the heat pump system was measured by varying the mass flow rate ratio. The experimental results show that the heating capacity and COP in the dual heat source heat pump were increased by 20.9% and 8.6%, respectively, from those of the air-source heat pump.

Fruit Characteristics Based on Leaf to Fruit Ratio in 'Pione' Grapevine (Vitis vinifera × V. labrusca) during Cultivation with Heating (가온 재배 시 '피오네' 포도(Vitis vinifera × V. labrusca)의 엽과비에 따른 과실 특성)

  • Yun, Seok Kyu;Park, Seo Jun;Jung, Sung Min;Kim, Jung Bae;Yoon, Ik Koo;Nam, Eun Young;Yu, Duk Jun;Lee, Hee Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.1
    • /
    • pp.57-62
    • /
    • 2014
  • BACKGROUND: Defoliation in grapevine cultivation is practically used to improve light environment within the canopy and thereby fruit quality. Effects of defoliation in five-year-old 'Pione' grapevine during cultivation with heating were investigated to find out optimum ratio of leaf area to fruit cluster weight (L/F). METHODS AND RESULTS: The grapevines were defoliated with berry-thinning 20 days after full bloom to provide various levels of L/F. At harvest, total leaf area values of fruit bearing branches were between 0.23 and $0.60m^2$. With increasing L/F, soluble solids and anthocyanin contents curvilinearly increased ($R^2=0.76^{**}$). At L/F over $0.6m^2/kg$, soluble solids content (SSC) leveled off. With increasing L/F, titratable acidity (TA) linearly decreased ($R^2=0.87^{**}$), but the ratio of SSC to TA linearly increased ($R^2=0.86^{**}$). Anthocyanin content was significantly correlated with SSC and the ratio of SSC to TA ($R^2=0.80^{**}$ and $0.82^{**}$, respectively). When total leaf area per fruit bearing branch was maintained $0.40m^2$, soluble solids and anthocyanin contents linearly decreased ($R^2=0.79^{**}$ and $0.85^{**}$, respectively), but TA linearly increased with increasing fruit cluster weight ($R^2=0.70^{**}$). Fruit was low in quality when the L/F was below $0.6m^2/kg$. CONCLUSION: L/F is recommended to be maintained at least $0.6m^2/kg$ in 'Pione' grapevine during cultivation with heating to produce higher-quality fruits.

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.

Shape-Stabilized Phase Change Materals : Frozen Gel from Polypropylene and n-Octadecane For Latent Heat Storage

  • Son, Tae-Won;Kim, Tae-Hun;Kim, Bong-Shik;Kim, Byung-Giu
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.375-375
    • /
    • 2006
  • The preparation methods are to be used as "melting method" and "absorption method", respectively. The reaction mixture in the reaction container was heating up the reaction mixture to $200^{\circ}C$ for 2 hour. The mixing time of lab scale preparation should be provided quit long, instead of the short working time in a compounder vessel. And The PP-PCM mixture in the reaction container was heating up the mixture around $60-80^{\circ}C$ for 2 hour. A melting method of frozen gel with 50/50 weight ratio of polypropylene-normal octadecane was prepared by adding PP chip and normal octadecane. An absorption method of frozen gel with 70/30 weight ratio of PP 4.8-normal n-octadecane was prepared by adding PP powder and normal octadecnae.

  • PDF

Development of Micro Cooling System for Telecommunication System using Oscillating Heat Pipe (진동 세관형 히트파이프를 이용한 통신 기기용 마이크로 냉각시스템의 개발)

  • Ha, Soo-Jung;Bae, Nae-Soo;Park, Chul-Min;Kim, Jung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1499-1505
    • /
    • 2003
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices. So, in this paper, characteristics on oscillating heat pipe according to operating conditions(environment temperature, charging ratio of working fluid, inclination) based on experimental study was investigated. From the experimental results, $25^{\circ}C$environment temperature), R-141b(working fluid)40%(charging ratio) was best performace at others of inclination angle and The top heating mode of OCHP performed 80% efficiency of the bottom heating mode.

  • PDF

Laser Cutting of Thick Diamond Films Using Low-Power Laser (저 출력 레이저를 이용한 다이아몬드 후막의 절단)

  • 박영준;백영준
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.2
    • /
    • pp.140-144
    • /
    • 2000
  • Laser cutting of thick diamond films is studied using a low-power(10 W) copper vapor laser. Due to the existence of the saturation depth in laser cutting, thick diamond films are not easily cut by low-power lasers. In this study, we have adopted a low thermalconductivity underlayer of alumina and a heating stage (up to 500$^{\circ}C$ in air) to prevent the laser energy from consuming-out and, in turn, enhance the cutting efficiency. Aspect ratio increases twice fromm 3.5 to 7 when the alumina underlayer used. Adopting a heating stage also increases aspect ratio and more than 10 is obtained at higher temperatures than 400$^{\circ}C$. These results show that thick diamond films can be cut, with low-power lasers, simply by modifying the thermal property of underlayer.

  • PDF

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.