• Title/Summary/Keyword: Heating Unit

Search Result 498, Processing Time 0.024 seconds

Structural Analysis & Phase Transition of Amorphous Silica Nanoparticles Using Energy-Filtering TEM (EF-TEM을 이용한 비정질 실리카 나노입자의 구조 및 상전이 연구)

  • Park, Jong-Il;Kim, Jin-Gyu;Song, Ji-Ho;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • In this study, we introduce the structural analysis of amorphous silica nanoparticles by EF-TEM electron diffraction and in-situ heating experiments. Three diffused rings were observed on the electron diffraction patterns of initial silica nanoparticles, while crystalline spot patterns were gradually appeared during the insitu heating process at $900^{\circ}C$. These patterns indicate the basic unit of $SiO_4$ tetrahedra consisting amorphous silica and gradual crystallization into the ideal layer structure of tridymite by heating. Under high vacuum condition in TEM, SiO nanoparticles were redeposited on the carbon grid after evaporation of SiO gas from $SiO_2$ above $850^{\circ}C$ and the remaining $SiO_2$ were crystallized into orthorhombic tridymite, consistent with ex-situ heating results in furnace at $900^{\circ}C$.

Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery (폐용제 회수용 이중관형 열교환기 특성 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • This study describes to analyze the heat transfer characteristics of waste solvent recovery system using a double pipe heat exchanger heating solvent by the hot oil. The solvent recovery system consists of the feeding pump, the double pipe heat exchanger, the vacuum spray chamber, and the condenser. A double pipe heat exchanger consists of the first section to conduct the heating of solvent to the thermal saturated point and the second section to evaporate the saturated solvent. The heat transfer area for vaporization of water, benzene and alkylbenzene was predicted by the heat balance modelling and experimentally measured from the temperature distribution as a function of solvent flow rate and heating temperature. The required heat transfer area for vaporization was increased with increasing solvent flow rates and with decreasing heating temperatures due to decreased quantity of transferred heat per the unit area. Theoretical modelling of the heat transfer area for solvents vaporization in the pipe showed good agreement with experimental results. Results showed to be suitable for the waste solvent recovery using a double pipe heat exchanger.

  • PDF

Analysis and Comparison of Standard and Existed Heating Degree-Hours Model for decision of Greenhouse Heating Load in Korea (온실의 난방부하 결정을 위한 Degree-Hour 모델식 비교 분석)

  • Woo, Young-Hoe
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.6 no.1
    • /
    • pp.143-154
    • /
    • 2004
  • The value of daily heating degree hour(described as DH hereafter) is essential for calculating the heating load of a greenhouse during the winter months. Many researchers have so for proposed different models for estimating DH value. Models for estimating DH have been investigated DH(unit, ℃·h·year-1) in this paper. The comparisons of standard and existed DH values were made to know the estimation error of each model proposed so far. The standard DH values and other proposed DH values have were obtained for the inside setpoint temperatures of 9, 13, 16 and 20℃ in greenhouse, estimated based on meterological data from 1961 to 2000 according to locals, and standard DH values were independent and existed DH values were dependent. Among the various model, the one developed theoretically by Mihara modified to author was the best fitting for standard DH values. The DH values were obtained for the inside setpoint temperature of 9, 13, 16 and 20℃ by Modified Mihara's model. A new DH contour line graph was proposed using Modified Mihara's model. Using the DH contour line graph, the DH values can be obtained easily for any setpoint according to local.

Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source (R123 열원 적용 증발식 담수 시스템 특성 연구)

  • Yun, Sang-Kook;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

A Study on the Space Size Analysis in the Multifamily Housing in aspect of management cost. -Focused on the Central Heating System using the diesel, kerosene- (공동주택 관리비용에 따른 적정공간규모 산정에 관한 연구 -경유, 등유를 사용하는 중앙집중난방방식을 중심으로 -)

  • 이강희;양재혁
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.89-99
    • /
    • 2002
  • The multifamily housing has various advantages in construction cost, land-use intensity. KRIHS(1997) recommended the proper scale of th multifamily housing as 800 households in constructability, 1,000 households in facility compactability, 500 households in social aspect. At the early planning stage of project, the size of the multiftmily housing has, until now, been maximizingly considered under the regulation on which has been emphasized at the building volume ratio, land area, etc., except for the expenditure during the maintenance stage. This paper aimed at providing the proper size of multifamily housing in aspect of area and household number with maintenance cost at the early stage of project. For these, it took 곧 average cost function which is made from the 3-rd quardratic form and analyzes the unit increasing rate of the average cost. It surveyed in nationwide focused on the central heating system using diesel and kerosene. The number of samples is 88 and items of management cost is 11. The results are as follows ; first, 3rd-order quadratic function is proper at explaining the cost variation, considering the multicollinearity and statistics. Second, the proper size of multifamily housing is recommended with 83,000 $m^2$ on management area, 820 or over the 2,630 household number in aspect of total management cost.

A Study on the Deformation of Cable Pipes via Induction Bending (고주파 벤딩을 통한 케이블 파이프의 변형에 관한 연구)

  • Joo, Yi-Hwan;Qin, Zhen;Moon, Seongmin;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.4
    • /
    • pp.79-84
    • /
    • 2020
  • Induction bending via high-frequency heating is widely used for manufacturing pipe and section steel bends. It allows productivity improvement, unit cost reduction, delivery time compliance, and good mechanical properties. The recent increase in high-end vessels and offshore plants has raised the demand for high-frequency bending, which should improve the product quality and reduce the costs by simplifying the fabrication process; therefore, the characteristics and performance of this technique must be studied and proper design technology is required. During hot pipe bending via induction heating, the outward wall thickness of the pipe is thinned due to tensile stress and this thickness reduction cannot exceed 12.5%. This study focused on pipe bends with a bending curvature of 5D and their optimization design; in particular, the conditions that can both improve the productivity of the high-frequency bending process and keep the maximum thickness reduction below 12.5% were determined.

Changes in Phytochemical Stability and Food Functionality during Cooking and Processing (식품의 조리.가공 공정 중 phytochemical 및 기능성의 변화)

  • Kim, Hyun-Jung;Chun, Hyang-Sook
    • Korean journal of food and cookery science
    • /
    • v.22 no.3 s.93
    • /
    • pp.402-417
    • /
    • 2006
  • Research interest on functional food and phytochemicals has mainly focused on their health effects, mechanism of action and structure-activity relationship for the development of nutraceuticals. Considering the intake of phytochemicals via the normal diet, further information is required on changes in food functionality or individual phytochemicals that occur during the cooking or processing of foods, in order to increase the intake of these bioactive compounds, because many of the unit-operating procedures involved in cooking or food processing may result in physicochemical changes of food constituents. This study reviews the changes of selected phytochemicals, i.e. flavonoids, organosulfur compounds and carotenoids, or food functionality by major cooking or processing procedures such as heating, fermentation, and pH changes. In general, heating has a negative effect on food functionality, although in some cases, mild heating increases bioactive phytochemical contents. Some phytochemicals, including anthocyanins and catechins, are stabilized in lower pH conditions. The structures of phytochemicals, including isoflavones and catechins, are changed by fermentation. The loss of bioactive compounds may be decreased by recently developed cooking or processing methods such as microwave cooking or use of high hydrostatic pressure. However, the effects of cooking and processing procedures on food functionality and phytochemicals are so diverse and dependent on test conditions that further research efforts are needed to form accurate conclusions on the effects of cooking and processing of foods.

Optical Analysis and Experimental Method for Design of Radiative Thermal Reflector (복사열 반사판의 설계를 위한 광학적 해석 및 실험기법)

  • Jung, Hae-Yong;Song, Tae-Ho;Yoo, Seung-Yeol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.563-569
    • /
    • 2008
  • Radiative, heating is suitable for outdoor heating system in windy and cold seasons. Optimal design of the reflector is very important to maximize heat transfer to a specific target area in the open space. The geometrical optical theory can be applied to analyze efficiency of the reflector. Commercial ray tracing computer programs are available only for limited geometries of the reflector. Alternatively, it may be designed and analyzed through an approximated simple lens theory. Two types of reflectors are analyzed using either of these methods. The key issue in this paper is to propose a new illumination experimental method for determination of the radiative efficiency. Optical light source and illuminometer are employed. The calculated efficiency of the reflector is compared with experimental one for checking the reliability. The relative errors between the experimental and analytical results are less than 5%, which proves the validity of this method. Based on these methodologies, a practical reflector and heating lamp unit is developed.

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner with high-head and long-line conditions (동시냉난방 시스템 에어컨의 고낙차 장배관 운전 신뢰성 평가)

  • Kim, Tae-An;Lee, Seung-Chan;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.609-614
    • /
    • 2008
  • The heating and cooling performance of system multi-air conditioner under high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with 22 different working conditions. Experimental results were prepared on the p-h diagram. Also the oil level in the compressor was normally maintained at the safety zone for the system multi-air conditioner with high-head and long-line conditions.

  • PDF

Study on Improvement of Air Conditioning Units for Anti Aircraft Gun Wheeled Vehicle (차륜형 대공포 냉방장치 성능개선 연구)

  • Jeon, Ki-Hyun;Lee, Dong-Hui;Lee, Boo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1099-1103
    • /
    • 2013
  • A combat vehicle needs to have an air-conditioning unit. Accordingly, new combat systems have tended to apply an integrated heating, cooling, and ventilating system. The air conditioning unit used depends on the combat vehicle's purpose of use. In this study, we studied an air-conditioning unit for an armored combat vehicle as a special use and military specification and tried to improve the air-conditioning unit's performance.