• Title/Summary/Keyword: Heating Function

Search Result 472, Processing Time 0.026 seconds

Three-dimensional Equivalent Transient Ground Heat Exchanger Thermal Analysis Model by Considering Heating and Cooling Operations in Buildings (건물의 냉난방 운전을 고려한 3차원 동적 지중 열교환기 열해석 모델)

  • Baek, Seung Hyo
    • Land and Housing Review
    • /
    • v.9 no.4
    • /
    • pp.25-32
    • /
    • 2018
  • Application of geothermal energy in buildings has been gaining popularity as it provides the benefits of both heating and cooling a building. Among the various types of geothermal energy systems, ground-coupled heat pump system is the most commonly applied one in South Korea. A ground heat exchanger plays an important role as a heat source in winter and a heat sink in summer. For the stable operation of a ground-coupled heat pump system, a ground heat exchanger should be sized so that it provides sufficient heating and cooling energy. Heating and cooling energies generated in ground heat exchangers mainly depend on the temperature difference between the heating medium in ground heat exchangers and the surrounding ground. In addition, the performance of ground heat exchangers influences the change in ground temperature. Therefore, it is necessary to consider this interrelation between the change in the ground temperature and the performance of ground heat exchanger for an accurate estimation of its performance. However, previous thermal analysis models for ground heat exchangers are not competent enough to allow a complete understanding of this interrelation. Therefore, this study proposes a three-dimensional equivalent, transient ground heat exchanger analysis model. First, a previous thermal analysis model for ground heat exchangers, including an analytical model, a g-function, and a numerical model are analyzed. Next, to overcome the limitations of the previous models, a three-dimensional equivalent, transient ground heat exchanger model is proposed. Finally, this study validated the proposed model with the measurement data of the thermal response test, sandbox test, and TRNSYS DST model. All validation results showed a good agreement. These findings helped us to investigate the thermal performance of ground heat exchangers more accurately than the analytical models, and faster than the numerical models. Furthermore, the proposed model contributes to the design of ground heat exchangers by considering the different operation conditions of buildings.

The demand for air conditioning in rural city (지방 대도시의 냉난방 설비시장의 수요자 요구)

  • 윤정숙
    • Journal of the Korean housing association
    • /
    • v.6 no.2
    • /
    • pp.205-212
    • /
    • 1995
  • The objective of this study were to determine new air conditioning's selling possibility and discriminate it's market in Pusan and Daegu. The data were collected by using questionnaire. On the basis of the findings. These are follwing conclusions : Come to think of using rates of air conditioning. Function of air conditioning in house is not satisfied nowadays. Residents prefer it's function of cooling plus heating to only cooling in order to use a air conditioning in winter and the turning point of the season. And the air conditioning should be furnished economy, environment, convenience, amenity, safety.

  • PDF

Estimation of Heat Sterilization Time of Chinese Laminae Species Used in The Production of Glue-laminated Board (집성재 제조용 중국산 층재 수종의 적정 열처리 시간 평가)

  • Kim, Min-Ji;Shin, Hyun-Kyeong;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.760-766
    • /
    • 2016
  • This study explored the effects of heating temperature and laminae thicknesses on the time required to heat the center of air-dried Paulownia tomentosa, Pinus sp., Abies sp., and Larix sp. laminae to $56^{\circ}C$, which is a minimum core temperature of wood packaging materials defined by ISPM 15 standard, and maintain for 30 minutes in dry heat treatment schedule. Heating times were different among wood species and were Pinus sp. ${\geq}$ Abies sp. > Paulownia tomentosa > Larix sp. in decreasing order. The differences in heating times of some species were significantly different statistically, but were not different enough in practical terms to warrant heating four species separately. Heating times decreased as heating temperature increased and followed approximately power-function relationship. Also, heating times increased linearly with increasing laminae thickness. These relationships make it possible to calculate intermediate heating times relative to experimentally observed heating times. The results of this study will serve as a guideline for heat sterilization of Chinese laminae species to meet heat treatment requirements for protection against invasive pests.

Development and Evaluation of an Automated Stainer for Mycobacterium Tuberculosis (결핵균 자동염색기의 개발 및 평가)

  • Kim, S. C.;Kang, S. I.;Kim, S. C.;Hwang, J. H.;Kim, S. Y.;Kim, Y.;Song, S. D.;Cho, S. N.;Kim, D. W.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.235-241
    • /
    • 2002
  • The detection of tubercle bacilli (TB) from sputum smear is one of the fast and inexpensive methods for diagnosis of tuberculosis. For this method. sputum smears are usually flexed by heating and stained by acid-fast staining method, and then examined under an optical microscope. Two Procedures are commonly used fur TB staining. One is hot staining and the other is cold staining method. The Ziehl-Neelsen method which is a hot staining method is widely used in Korea because its stained color is more vivid However, the conventional automated stainer has to fix the sputum smear on a slide manually and the stain is not so vivid because it has not heating function. In an effort to save labor and minimize variations in manual staining Procedure. we developed an automated stainer with heating function. The entire staining process is fully automated. from fixation to final washing and drying. With the automated methods, five slides can be flexed and stained in 21 minutes at consistent high quality We compared the concordance rate between the two methods for 91 sputum samples to validate the stain quality of the developed automated stainer. As the results, the concordant rate between the two methods was 95% and there was no significant difference (p>0.05)

Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater (세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증)

  • Ahn, Sung-Su;Kim, Woo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.151-159
    • /
    • 2016
  • This paper proposes a ceramic heating element-based tankless instant electric water heater for hand/face washing that does not require a lot of hot water. The heating module, which heats the input water and outputs hot water, operates the ceramic heating element detecting input water using a flow sensor. Inside of the heating module is designed to form one flow path in order to get almost $15^{\circ}C$ increased heated water compared to the input water temperature within 2 second after 1.5 liter per minute water supply. The design validity is verified using a heat flow analysis of the water flow and temperature variations inside of the heating module also. Based on the design data, the heating module is constructed including a single rod-type ceramic heating element. After that, a prototype system having temperature setting function by three steps were constructed. The prototype system is connected to a 1.5 liter per minute water supply line, and the water output temperature and time measurement experiments confirmed that the proposed system output the heated water increased by $18.3^{\circ}C$ in case of third step setting within 2 second after water supply. And standby power is under 1 W and peak power does not exceed the permissible range for the general house usage. Several performance results verify that the proposed tankless instant electric water heater is applicable for the washstand of the house, highway rest area and factory so on as winter-time hand/face washing.

Analysis of Isoflavone Contents of Soybean By-products with Acid Hydrolysis Method (산 가수분해시 가열방법과 시간 및 추출조건에 따른 대두가공 부산물의 이소플라본 함량 변화)

  • Han, Jin-Suk;Hong, Hee-Do;Kim, Sung-Ran
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.10
    • /
    • pp.1420-1426
    • /
    • 2006
  • To establish a rapid and effective method for the analysis of soy isoflavone which is known to have lots of variation in derivatives of glucoside, conversion rate from isoflavone conjugates to its aglycones, and decomposition of conversed aglycones were investigated with various acid hydrolysis conditions. A number of heating conditions for acid hydrolysis including heating at convection oven $(105^{\circ}C)$, water bath $(95^{\circ}C)$, heating block $(120^{\circ}C)$, and hot plate $(120^{\circ}C)$ were applied. Acid hydrolysis in heating block with reflux was chosen as the best heating condition. From the stability test of isoflavone aglycone during acid hydrolysis, genistein, daidzein, and glycitein did not show any significant changes in their contents for 60 min of hydrolysis. Ten to thirty milligram of sample per 1 mL HCl was the best ratio of sample to acid. As conclusion, acid hydrolysis for 60 min after addition of 15 mL HCl solution to 0.5 g soybean, and then fill up to 50 mL with methanol, followed by HPLC analysis was set as a final analysis method. From this method, isoflavone contents expressed as total aglycone of feed meal was the highest with content of $1288.5{\mu}g/g$ followed by those of dehulled meal.

Estimation of Physical Properties of Natural Gas Using Cubic Equations of State (3차형 상태방정식을 이용한 천연가스의 물성 추산)

  • Cho, Jung-Ho;Cho, Kyu-Sang;Kim, Dong-Hyeok;Lee, Young-Chul;Hong, Sung-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.6-10
    • /
    • 2006
  • In this study, gross heating value(GHV), density, vapor pressure and heat capacity of natural gas were estimated and their experimental data were compared with calculated ones, SRK method. A new alpha function was used to predict the vapor pressures of pure component of the natural gas constituents well instead of calculating vapor pressures with acentric factors. And binary adjustable parameters were determined by regressing binary vapor-liquid equilibria data. Through this study, our results showed good agreements with experimental data.

  • PDF

Viscoelastic Properties of MF/PVAc Hybrid Resins as Adhesive for Engineered Flooring by Dynamic Mechanical Thermal Analysis

  • Kim, Sumin;Kim, Hyun-Joong;Yang, Han-Seung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.37-45
    • /
    • 2006
  • The viscoelastic properties of blends of melamine-formaldehyde (MF) resin and poly(vinyl acetate) (PVAc) for engineered flooring used on the Korean traditional ONDOL house floor heating system were investigated by dynamic mechanical thermal analysis (DMTA). Because MF resin is a thermosetting adhesive, the effect of MF rein was shown across all thermal behaviors. The addition of PVAc reduced the curing temperature. The DMTA thermogram of MF resin showed that the storage modulus (E') increased as the temperature was further increased as a result of the cross-linking induced by the curing reaction of the resin. The storage modulus (E') of MF resin increased both as a function of increasing temperature and with increasing heating rate. From isothermal DMTA results, peak $T_{tan{\delta}}$ values, maximum value of loss modulus (E") and the rigidities (${\Delta}E$) of MF/PVAc blends at room temperature as a function of open time, peak $T_{tan{\delta}}$ and maximum loss modulus (E") values were found to increase with blend MF content. Moreover, the rigidities of the 70:30 and 50:50 MF/PVAc blends were higher than those of the other blends, especially of 100% PVAc or MF. We concluded that blends the MF/PVAc blend ratios correlate during the adhesion process.

Temporal and Spatial Variability of Sound Speed in the Sea around the Ieodo (이어도 주변해역에서 수중음속의 시공간적 변동성)

  • Park, Kyeongju
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1141-1151
    • /
    • 2020
  • The impact of sound speed variability in the sea is the very important on acoustic propagation for the underwater acoustic systems. Understanding of the temporal and spatial variability of ocean sound speed in the sea around the Ieodo were obtained using oceanographic data (temperature, salinity). from the Korea Oceanographic Data Center, collected by season for 17 years. The vertical distributions of sound speed are mainly related to seasonal variations and various current such as Chinese coastal water, Yellow Sea Cold Water (YSCW), Kuroshio source water. The standard deviations show that great variations of sound speed exist in the upper layer and observation station between 16 and 18. In order to quantitatively explain the reason for sound speed variations, Empirical Orthogonal Function (EOF) analysis was performed on sound speed data at the Line 316 covering 68 cruises between 2002 and 2018. Three main modes of EOFs respectively revealed 55, 29, and 5% the total variance of sound speed. The first mode of the EOFs was associated with influence of surface heating. The second EOFs pattern shows that contributions of YSCW and surface heating. The first and second modes had seasonal and inter-annul variations.

An Experimental Study on a Heat Pump with Dehumidification Function that Utilizes Underground Air Heat (지하공기열 히트펌프 제습기에 관한 실험적 연구)

  • Ko, Ji-Woon;Park, Youn Cheol;Ko, Gwang-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • The present study has been conducted to develope a heating system for a green house with heat from underground air at Jeju Island. The temperature of the air deposited in the underground is $16{\sim}18^{\circ}C$ throughout the year, and it also has a large amount of moisture. Therefore, the air could not directly used for the heating of a green house. In this study, a heat pump with dehumidification function has been developed, which consisted of three evaporators, where the moisture removal occurs, accompanied by temperature drop. The dropped temperature is recovered, while passing through a series condenser. The air temperature increased from $17^{\circ}C$ to 35 with a 2.1 kg/h of moisture removal rate. The developed system moisture removal performance shows 0.91 kg/kWh.