• 제목/요약/키워드: Heating Condition

검색결과 1,304건 처리시간 0.028초

가열조건에 따른 마른김의 색택 변화 연구 (Color change of dried laver according to heating conditions)

  • 이경인;이근직;윤영승
    • 한국해양바이오학회지
    • /
    • 제16권1호
    • /
    • pp.19-25
    • /
    • 2024
  • To verify the color change in dried laver postproduction during the heating process, chromaticity elements were compared via a spectrophotometer across various heating conditions within the visible light spectrum. In general, the moisture reduction rate increased with rising temperature and time. Surface image comparisons revealed an expanded area of light reflection on the heat-treated dried laver sample due to surface roughening from shrinkage. No statistically significant differences in chromaticity values were observed in the measurements of brightness (L*), redness (a*), and yellowness (b*). Reflectance spectrum measurements in the visible light region confirmed high reflectance under red wavelength conditions. In particular, a significant increase in reflectance at 700 nm compared with untreated samples was noted. The correlation between the increase in 700 nm reflectance of dried laver samples and heating conditions ranged from 0.7471 to 0.7793, suggesting its potential use as an indicator for comparing color changes in dried laver based on heating conditions.

혈관내피세포에 열 충격 부과시 죽력이 stress proteins의 발현에 미치는 영향 (Effects of Bambusae Caulis in Liquamen on the Stress Proteins Induced by Heating in Endothelial Cells)

  • 전훈
    • 동의생리병리학회지
    • /
    • 제18권2호
    • /
    • pp.496-499
    • /
    • 2004
  • We have previously observed that Bambusae Caul is in Liquamen (BCL) stimulates the adipose conversion of 3T3-L1 cells and molecular chaperones were involved in the process of the assembly and replacement of laminin subunits in Bovine aortic endothelial cells(BAEC). Endothelial cells are exposed to continuous shear stress due to the blood flow. Heat shock protens(hsp) are a well-known stress response protein, namely, stress proteins. To investigate effects of BCL on the stress proteins induced by heating in endothelial cells, we have analyzed synthetic amounts of stress proteins in sodium dodecyl sulfate gel electrophoresis under reducing conditions. Under the condition of heating stress, BCL inhibited the synthesis of stress proteins in endothelial cells. These results suggest that BCL may have an important role for expression of stress proteins induced by heating in endothelial cells.

시판 발열조끼의 주관적 착용평가 (Subjective Wearing Evaluation of the Commercial Electric Heated Vest)

  • 이현영;정연희
    • 한국생활과학회지
    • /
    • 제19권4호
    • /
    • pp.667-674
    • /
    • 2010
  • This study evaluated the convenience and heating performance of 4 heated vests on the market through a trial of the vests. Participants were four healthy men who wore the garments outside in cold temperatures typical of the garments' real conditions of use. As the results, all the participants preferred the product, having an easily operable controller in ergonomic aspects and the good insulation for keeping the body temperature. The heating performance of vests was the most important factor in selecting the best product in this test. Indeed, the vests themselves found not to be sufficiently warm in the experimental condition. Thus, heated vests with the enhanced heating performance should be developed so that temperatures in the allowed range can be safely accessed.

열원을 가지고 상부가 개방된 사각공간내의 유동에 대한 수치 해석 (A Numerical Analysis in Top Opening Rectangular with a heating source)

  • 배강열;배철환;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.321-327
    • /
    • 2000
  • This study represents numerical analysis in top opening rectangular with a heating source. The governing equations were solved by a finite volume method, a SIMPLE algorithm was adopted to solve a pressure term. The top boundary with free surface was calculated by energy balance condition. As the results of simulations, the magnitudes of the velocity vectors and isotherms were very small at the lower space of a heating source. The mean Nusselt numbers are increased proportionally to the Grashof number, the heat transfer at Y/H=0.25 was greater than other positions.

  • PDF

태양열이용 Baffle형 축열탱크를 갖는 온수난방시스템의 열성능 해석 (Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank)

  • 서정세;이중섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.768-773
    • /
    • 2009
  • A numerical study has been performed to investigate the thermal Performance of Solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

  • PDF

식품위생관련 세균에 대한 가열처리 조건의 최적화 (Optimization of Heating Conditions for Bacteria Associated with Food Hygiene)

  • 이보순
    • 한국식품영양학회지
    • /
    • 제12권6호
    • /
    • pp.569-574
    • /
    • 1999
  • Response surface methodology(RSM) was applied to determine the optimum heating conditions(tem-perature and time) for the inactivation of bacteria associated with food hygiene. Coefficients of determinations(R2) for the cell growth were 0.9155(P<0.05) in Pseudomonas aeruginosa 0.8997(P<0.05) in Escherichia coli 0.9690(P<0.01) in Salmonella typhimurium 0.9393(P<0.05) in Enterobacter aerogenes and 0.7905 in Vibrio parahaemolyticus. The growth of strains was significantly affected by the temperature and time and reaction to temperature was most closely correlated to the inhibition of growth. On the basis of superimposed contour maps of cell growth the optimum range of heating conditions were 55.62-6$0^{\circ}C$ and 19.25-30 min.

  • PDF

바닥충격음 완충재의 동탄성계수 특성 및 측정 영향인자 (A Study On the Property and Influence Factor in Measuring of the Dynamic Stiffness of Damping Materials)

  • 김경우;최현중;강재식;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1256-1259
    • /
    • 2006
  • The purpose of this study was to investigate the current status and influence factor in measuring the dynamic stiffness of damping materials. The property of the dynamic stiffness of damping materials was tested and analysed in condition such as the size of test samples and the change of relative humidity in heating chamber. Test results showed that the dynamic stiffness of after-heating was lower than that of before-heating in most samples and the change of relative humidity in heating chamber got little influence of the dynamic stiffness. The resonant frequency of test sample decreased $2{\sim}7Hz$ as the decrease of the size of sample. Because it was increased that total mass per unit area of sample, the change of dynamic stiffness had little influence.

  • PDF

지중온도를 이용한 지하공간 벽체의 난방부하 계산에 관한 연구 (A study about caculating the heating load of the wall of underground space to be used undereground temperature)

  • 정수일
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.19-24
    • /
    • 2008
  • The energy crisis is culminating for the life of the fossil fuel in the future which is come to end at $30{\sim}40$ years. Moreover above 90% of the energy in our country depend on importing and the crisis is more seγious than it of other countries. So architects devote low energy house research and it means underground space research have become public opinion. But there is not an accurate and utility method calculating the heating load of underground space. In this study it is proposed that the heating load is calculated by setting adiabatic thichness of soil and predicting underground temperature. The prediction of the underground temperature is calculated by the latitude, the level, the distance from sea, the condition of earth surface.

철도차량 냉방 및 난방장치의 환경성능 시험방안 연구 (Study on the environmental performance test of cooling and heating equipments' of passenger cabin)

  • 조영민;이준석;박덕신;권순박;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.223-228
    • /
    • 2009
  • Cooling and heating equipments of railroad passenger cabin is one of the most important part in keeping the good thermal comfort of the passengers. The bad performance of these equipments usually results in the comfort of the passengers. However, there is no testing method for cooling and heating equipments during manufacturing the passenger car, and calculation method is frequently used. Many railroad operators spend a lot of money for the maintenance. In this study, a new environmental performance test for railroad passenger cabin was suggested. The temperature of the chamber will be changed from $-40^{\circ}C$ to $60^{\circ}C$. The performance test of cooling and heating equipment in controlling the passenger cabin temperature was carried out under various temperature condition. The testing method to investigate the effect of artificial sunlight irradiation on the passenger cabin temperature was also suggested.

  • PDF

에너지수지를 고려한 혐기성소화시설의 운영방안 (Operational Strategy of Anaerobic Digesters Considering Energy Balance)

  • 홍성구;권순국
    • 한국농공학회논문집
    • /
    • 제50권4호
    • /
    • pp.59-66
    • /
    • 2008
  • Anaerobic digestion system is getting more attractive in that it produces biogas in the process of organic waste stabilization. Net energy production is important when biogas production is concerned. In this study, net energy production was evaluated with respect to biogas production and heat losses in a hypothetical digester. Under the condition of digester operation with slurry inflow of 5% of TS, additional fuel is required to maintain digester temperature during the winder season. Substrate therefore, needs to have higher VS contents through co-digestion of silage or food waste that has greater values of methane production rate. Heating input slurry is important in cold season, which covers over 80% of heating requirement. Heat recovery from digestate is valuable to reduce the use of biogas for heating. It seems desirable to minimize slurry inflow when temperature is very low. Psychrophilic digestion may be a feasible option for reducing heating requirement.